6.3.1
Worktops
The equipment (the example in the
figure is the
DM 40
) has been
designed for use on a rigid worktop
parallel to the floor. Suitable worktops
include service furniture (where the
operator is standing) or modelling tables
(where work is done sitting down). All
worktops must be checked for stability.
The oven must be installed in a protected area using guards equipped with
systems that allow only frontal access (gates, shutters etc.).
Should the above-described connection be necessary it is essential that no
elbows or bends be created as combustion fumes and gases would no longer
be drawn outwards.
Position the equipment so that the fan flue is beneath the mobile hood
aspiration tube.
The aspiration fan flue must be free and must not be connected to other tubes or hood ducts.