4.2.2 To refer the battery cover reed polarity direction, insert into one 3V button battery; 

4.2.3 Close the battery cover.   

Warnings: 

When the oxygen terminal appears low voltage, please change the battery in 

time. If it is not used for a long time, remove the battery, so as to avoid battery leakage. 

 

4.2  Installation  and  use  of  the  Mobile  Infra-red  Ear  Thermometer  management 

software, see 

“Rapid use manual of mobile Mobile Infra-red Ear Thermometer” 

 

5 Method of use 

5.1 Correctly install the battery and the mobile APP software. 

5.2  Press  the  power  switch  of  the  infra-red  ear  thermometer  hardware,  the  blue  power 

indicator lamp will be light. 

5.3 Open the mobile APP software into the measurement interface. 

5.4 Insert the hardware into the mobile audio port according to guidance in the software, 

and then insert the probe into ear canal. 

5.5  Click  the  mobile  screen  to  start  measurement,  when  hear  the  buzzer  sound,  the 

measurement  is  finished,  get  out  the  probe,  and  the  measurement  results  will  be 

displayed in the mobile screen. 

5.6  The  infra-red  ear  thermometer  hardware  will  automatically  shutdown  in  absence  of 

new order. 

 

6 Maintenance and repair 

6.1 Don

’t fall or strongly collide the device. 

6.2 Avoid high temperature or exposure to the sun! 

6.3 When  clean  the  shell  or  rubber  pad,  firstly  turn  off  the  power,  use  soft  cotton  fabric 

dipped in a little neutral detergent gently wipe the surface, and dry naturally, it is prohibited 

high temperature baking! It is recommended to clean monthly. 

6.4 This product is strictly forbidden water! 

6.5 Please take out the battery if long term not to use, so as to avoid battery leakage! 

6.6 Do not disassemble the product body! 

6.7 It is forbidden to use this product for other purposes! 

6.8 The shelf life of the product is 5 years. To ensure the service life of the device, please 

pay attention to the device

’s maintenance.

 

 

7 Troubleshooting 

Abnormal 

phenomenon

 

Reason of analysis

 

Troubleshooting

 

Abnormal 

measurement 

values happen 

The  depth  of  the  probe  into  the  ear 

was  not  enough,  the  membrane 

temperature  was  not  successful 

measured. 

Adjust the direction and depth 

of the probe into the ear canal, 

and then measure again. 

Содержание IFU-MIET

Страница 1: ...Instruction for Use File No IFU MIET Version 01 Mobile Infra red Ear Thermometer Zhejiang Medzone Medical Equipment Co Ltd...

Страница 2: ...injury or property damage Warning To remind potential dangers or unsafe operations if not avoided may result in death or serious personal injury or property damage Caution To remind potential dangers...

Страница 3: ...use when your ear is wet after such as swimming bathing otherwise the ear hole may be hurt If the device storage environment is different from use environment please put the device firstly in the room...

Страница 4: ...ope The Mobile Infra red Ear Thermometer is intended to measure the human temperature by measuring the human ear cavity infrared radiation 3 3 Contraindications Who has Ear deformity external otitis O...

Страница 5: ...esults will be displayed in the mobile screen 5 6 The infra red ear thermometer hardware will automatically shutdown in absence of new order 6 Maintenance and repair 6 1 Don t fall or strongly collide...

Страница 6: ...Open the mobile phone bluetooth function No display after pressing power button Battery energy is completely consumed or no battery Change the battery Orange lamp flashing after pressing power button...

Страница 7: ...ection against liquid IPX0 Running mode continuous operation Safety classification of using with flammable anesthetic gas or flammable anesthetic gas mixed with oxygen or nitrous oxide Non AP APG 9 Gu...

Страница 8: ...cy 50Hz 60Hz Continuous field 3 A m Test duration 5m Antenna factor 0 917A m Axis X Y Z Test results No degradation of function comply with EN 60601 1 2 2007 AC 2010 ISO 80601 2 56 2009 Clause 202 EN...

Отзывы: