3 Product brief 

3.1  Product characteristics 

The Mobile Infra-red Ear Thermometer has a small size, low power consumption, easy to 

use and carry. During measurement, insert the hardware into the mobile audio port, and 

direct the infra-red probe facing the ear canal, the mobile screen will immediately display 

the measured temperature value, the device has high accuracy and repeatability. 

 

3.2  Scope 

The Mobile Infra-red Ear Thermometer is intended to measure the human temperature by 

measuring the human ear cavity infrared radiation. 

 

3.3 

Contraindications

   

Who has Ear deformity, external otitis, Otitis media, can not use the device. 

 

4 Prepare before use 

4.1  Structure of the product 

The  Mobile  Infra-red  Ear  Thermometer  consists  of  the  management  software  and 

measurement hardware which is composed of the infra-red temperature sensor,

 the

 micro 

controller (MCU), the audio port and the shell. 

 

Diagram 1 Measurement hardware structure 

 

4.2 How to install and change the battery 

4.2.1 To press the battery cover groove, slip outward and open the battery cover; 

 

Содержание IFU-MIET

Страница 1: ...Instruction for Use File No IFU MIET Version 01 Mobile Infra red Ear Thermometer Zhejiang Medzone Medical Equipment Co Ltd...

Страница 2: ...injury or property damage Warning To remind potential dangers or unsafe operations if not avoided may result in death or serious personal injury or property damage Caution To remind potential dangers...

Страница 3: ...use when your ear is wet after such as swimming bathing otherwise the ear hole may be hurt If the device storage environment is different from use environment please put the device firstly in the room...

Страница 4: ...ope The Mobile Infra red Ear Thermometer is intended to measure the human temperature by measuring the human ear cavity infrared radiation 3 3 Contraindications Who has Ear deformity external otitis O...

Страница 5: ...esults will be displayed in the mobile screen 5 6 The infra red ear thermometer hardware will automatically shutdown in absence of new order 6 Maintenance and repair 6 1 Don t fall or strongly collide...

Страница 6: ...Open the mobile phone bluetooth function No display after pressing power button Battery energy is completely consumed or no battery Change the battery Orange lamp flashing after pressing power button...

Страница 7: ...ection against liquid IPX0 Running mode continuous operation Safety classification of using with flammable anesthetic gas or flammable anesthetic gas mixed with oxygen or nitrous oxide Non AP APG 9 Gu...

Страница 8: ...cy 50Hz 60Hz Continuous field 3 A m Test duration 5m Antenna factor 0 917A m Axis X Y Z Test results No degradation of function comply with EN 60601 1 2 2007 AC 2010 ISO 80601 2 56 2009 Clause 202 EN...

Отзывы: