background image

Safety

 

Information

 

 

WARNING!

 

Installation

 

and

 

removal

 

of

 

the

 

unit

 

and

 

its

 

accessories

 

must

 

be

 

carried

out

 

by

 

qualified

 

personnel.

 

You

 

must

 

read

 

all

 

of

 

the

 

Safety

 

Instructions

supplied

 

with

 

your

 

equipment

 

before

 

installation

 

and

 

operation.

 

 

Warnings:

 

z

 

If

 

the

 

product

 

does

 

not

 

work

 

properly,

 

please

 

contact

 

your

 

dealer

 

or

 

the

 

nearest

 

service

 

center.

 

(We

 

shall

 

not

 

assume

 

any

 

responsibility

 

for

 

problems

 

caused

 

by

 

unauthorized

 

repair

 

or

 

maintenance.)

  

z

 

To

 

reduce

 

the

 

risk

 

of

 

fire

 

or

 

electrical

 

shock,

 

do

 

not

 

expose

 

this

 

product

 

to

 

rain

 

or

 

moisture.

  

z

 

This

 

installation

 

should

 

be

 

made

 

by

 

a

 

qualified

 

service

 

person

 

and

 

should

 

conform

 

to

 

all

 

the

 

local

 

codes.

  

z

 

Please

 

install

 

blackouts

 

equipment

 

into

 

the

 

power

 

supply

 

circuit

 

for

 

convenient

 

supply

 

interruption.

   

z

 

The

 

separate

 

earthing

 

terminal

 

must

 

be

 

permanently

 

connected

 

to

 

earth.

 

z

 

For

 

AC

 

supplied

 

model:

 

The

 

plug

socket

 

combination

 

must

 

be

 

accessible

 

at

 

all

 

times

 

as

 

it

 

serves

 

as

 

the

 

main

 

disconnecting

 

device.

 

z

 

Before

 

the

 

power

 

cable

 

is

 

installed

 

or

 

removed,

 

the

 

power

 

must

 

be

 

turned

 

off.

 

z

 

To

 

avoid

 

heat

 

accumulation,

 

good

 

ventilation

 

is

 

required

 

for

 

a

 

proper

 

operating

 

environment.

   

z

 

Improper

 

use

 

or

 

replacement

 

of

 

the

 

battery

 

may

 

result

 

in

 

hazard

 

of

 

explosion.

 

Please

 

use

 

the

 

manufacturer

 

recommended

 

battery

 

type.

 

Содержание DVS4016-IN

Страница 1: ...DVS4016 IN Video Encoder Quick Guide Manual Version P101 20140414...

Страница 2: ...ied Environmental Protection This product has been designed to comply with the requirements on environmental protection For the proper storage use and disposal of this product national laws and regula...

Страница 3: ...ry or equipment damage caused by incorrect cable connection z Power interruption may cause hard disk damage or abnormal functions To shut down the device strictly follow the instructions If power inte...

Страница 4: ...moisture z This installation should be made by a qualified service person and should conform to all the local codes z Please install blackouts equipment into the power supply circuit for convenient s...

Страница 5: ...protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in...

Страница 6: ...uropean Low Voltage Directive 2006 95 EC and EMC Directive 2004 108 EC WEEE Directive 2002 96 EC The product this manual refers to is covered by the Waste Electrical Electronic Equipment WEEE Directiv...

Страница 7: ...the DVS4016 IN to the Rack 11 Verifying Installation 11 Installing the DVS4016 IN on a Workbench 12 Preparing for the Installation 12 Installation Procedure 13 Connecting Cables 13 Cabling Requirement...

Страница 8: ...ii Verifying Installation 21 Starting Up the DVS4016 IN 22 3 Logging In to and Logging Out of the DVS4016 IN 22 4 Technical Specifications 23...

Страница 9: ...o video encoding and compression and data transmission They are applicable to monitoring and listening to remote sites in real time and can be widely applied to real time surveillance applications in...

Страница 10: ...x contact 6 Alarm in port 7 Alarm out port 8 RS 485 port RJ 45 9 Active LED 10 Link LED 11 RS 232 port 12 Ethernet port 13 USB port 14 Grounding screw 15 AC power input 16 Power switch LEDs Table 1 1...

Страница 11: ...being encoded Blinking are input ls a y a There signa nd the re being encoded Off input There are no signals ACT Blinking ce or The devi is transmitting receiving traffic Off The device is transmittin...

Страница 12: ...kohm 2V For more informatio see Figure 2 7 Inputs audio signals AUDIO OUT 2 Phoenix contact single channel 10 kohm 2V P P For more information see Figure 2 7 Outpu s audio signals Note Currently the...

Страница 13: ...gnals RS 485 2 RJ 45 contact Provides interactive device for example PTZ cameras connector Phoenix control with the connected RS 232 1 RJ 45 co Commissions nnector and maintains the device Ethernet po...

Страница 14: ...hree s s the device r ts z If yo and hold then release it the device will reboot and restore the factory defa configur n USB 1 for local buffering USB2 0 storage device For more information see Local...

Страница 15: ...age device is 5 Mbps by z Hot plugging is not recommended after you insert a USB storage device into the device If you pull out the USB storage device accident you need to restart the device otherwise...

Страница 16: ...e seal from the chassis cover of an DVS4016 IN without permission If you want to op WARNING chassis contact th shall not be held liable hecking the Ins C tallation Environment The device can be instal...

Страница 17: ...lling the DVS4016 IN in a Rack You can install your DVS4016 IN into a standard 19 inch rack in one of the following two modes z Forward installation of mounting brackets Mounting brackets are installe...

Страница 18: ...that the DVS4016 IN is to be installed to and make sure there is no obstacle inside or near the rack which may hamper the installation z Move the DVS4016 IN to a place near the rack Installing the Mou...

Страница 19: ...IN horizontally to an appropriate position in the rack Fix the two mounting brackets on the DVS4016 IN to the rack posts as shown in Figure 2 3 Figure 2 3 Install the DVS4016 IN to the rack Verifying...

Страница 20: ...tly Installing the DVS4016 IN on a Workbench If you do not have a standard 19 inch rack you can install your DVS4016 IN on a workbench Preparing for the Installation z Make sure the workbench is sturd...

Страница 21: ...n the DVS4016 IN Connecting Cables Cabling Requirements Route and bundle different types of cables power cables signal cables and ground wires separately You can bundle the long cables with cable ties...

Страница 22: ...dards For details about cable selection refer to DVS DC Cable Connection Guide z Do not bundle cables near the heat dissipation hole for fear of premature aging of cables z Fasten the cables near the...

Страница 23: ...ting to a serial device such as a PC through a serial cable 8 Ground 9 Connecting to a network through a network cable 1 2 3 8 1 5 6 7 4 9 Connecting the Ground Wire WARNING To prevent bodily injury a...

Страница 24: ...end of the ground wire to a grounding bar NOTE Generally a rack has a set of grounding bars where you can connect the ground wire In the actual installation you may connect the ground wire properly d...

Страница 25: ...ple speaker 5 Ground wire AUDIO OUT 1 1 G 2 2 1 2 G 3 4 5 6 G 7 8 1 2 G 3 4 5 6 G 7 8 ALARM IN ALARM OUT 1 1 G 2 2 1 2 G A B RS485 3 AUDIO IN 1 2 G 3 4 5 6 G 7 8 1 2 G 3 4 9 10 G 11 12 5 6 G 7 8 13 14...

Страница 26: ...e two pairs of alarm output terminals 1 1 through 2 2 of the phoenix contact port to four alarm output channels The positive negative symbols are for distinction instead of for representing the polari...

Страница 27: ...LED The alarm LED supports multiple connection modes Here only one connection mode is shown as an example 1 1 G 2 2 AUDIO OUT 2 1 1 2 G 3 4 5 6 G 7 8 1 2 G 3 4 5 6 G 7 8 ALARM IN ALARM OUT 1 1 G 2 2...

Страница 28: ...damage caused by electric power 1 Take out the power cable retention clip from the package and install it on the DVS4016 IN as shown inFigure 2 9 Figure 2 9 Installing the power cable retention clip...

Страница 29: ...n connect a third party device through the RS 485 port in transparent mode on the DVS4016 IN For details about how to connect the serial cable refer to DVS DC Cable Connection Guide RS 232 Serial Cabl...

Страница 30: ...ge and maintain your DVS4016 IN very conveniently through web interfaces Before you log onto the DVS4016 IN through the web interface make sure that z The DVS4016 IN is operating normally z The client...

Страница 31: ...on tree For your first login use admin as both the username and password We recommend you to change the default password by selecting Device Password after your first login To log out of the device cl...

Страница 32: ...196 85 to 13123 36 ft actually selected nnel number and stream relation For more information see the ding Web configuration page on the device CAUTION The video encoding rate and resolution depend on...

Страница 33: ...BOM 3101C03F...

Отзывы: