background image

 

17 

Appendix 5 Cybersecurity Recommendations 

Mandatory actions to be taken for basic equipment network security:

 

1. 

Use Strong Passwords

 

Please refer to the following suggestions to set passwords: 

  The length should not be less than 8 characters. 

  Include at least two types of characters; character types include upper and lower case letters, 

numbers and symbols. 

  Do not contain the account name or the account name in reverse order. 

  Do not use continuous characters, such as 123, abc, etc. 

  Do not use overlapped characters, such as 111, aaa, etc. 

2. 

Update Firmware and Client Software in Time

 

  According to the standard procedure in Tech-industry, we recommend to keep your 

equipment (such as NVR, DVR, IP camera, etc.) firmware up-to-date to ensure the system is 

equipped with the latest security patches and fixes. When the equipment is connected to the 

public network, it is recommended to enable the“auto-check for updates” function to obtain 

timely information of firmware updates released by the manufacturer. 

  We suggest that you download and use the latest version of client software. 

"Nice to have" recommendations to improve your equipment network security:

 

1. 

Physical Protection

 

We suggest that you perform physical protection to equipment, especially storage devices. For 

example, place the equipment in a special computer room and cabinet, and implement well-

done access control permission and key management to prevent unauthorized personnel from 

carrying out physical contacts such as damaging hardware, unauthorized connection of 

removable equipment (such as USB flash disk, serial port), etc. 

2. 

Change Passwords Regularly

 

We suggest that you change passwords regularly to reduce the risk of being guessed or cracked. 

3. 

Set and Update Passwords Reset Information Timely

 

The device supports password reset function. Please set up related information for password 

reset in time, including the end user’s mailbox and password protection questions. If the 

information changes, please modify it in time. When setting password protection questions, it is 

suggested not to use those that can be easily guessed. 

4. 

Enable Account Lock

 

The account lock feature is enabled by default, and we recommend you to keep it on to 

guarantee the account security. If an attacker attempts to log in with the wrong password several 

times, the corresponding account and the source IP address will be locked. 

5. 

Change Default HTTP and Other Service Ports

 

We suggest you to change default HTTP and other service ports into any set of numbers between 

1024–65535, reducing the risk of outsiders being able to guess which ports you are using. 

6. 

Enable HTTPS

 

We suggest you to enable HTTPS, so that you visit Web service through a secure communication 

channel. 

7. 

MAC Address Binding

 

We recommend you to bind the IP and MAC address of the gateway to the equipment, thus 

Содержание Face Recognition Access Controller

Страница 1: ...Face Recognition Access Controller User s Manual V1 0 1...

Страница 2: ...Release May 2022 Privacy Protection Notice As the device user or data controller you might collect the personal data of others such as their face fingerprints and license plate number You need to be...

Страница 3: ...the functions operations and technical data If there is any doubt or dispute we reserve the right of final explanation Upgrade the reader software or try other mainstream reader software if the manual...

Страница 4: ...ion Personnel working at heights must take all necessary measures to ensure personal safety including wearing a helmet and safety belts Do not place the Access Controller in a place exposed to sunligh...

Страница 5: ...ller under allowed humidity and temperature conditions Do not drop or splash liquid onto the Access Controller and make sure that there is no object filled with liquid on the Access Controller to prev...

Страница 6: ...Case Mount 5 3 Local Configurations 6 3 1 Initialization 6 3 2 Adding New Users 6 4 Web Configurations 9 4 1 Initialization 9 4 2 Logging In 10 Appendix 1 Important Points of Intercom Operation 11 App...

Страница 7: ...1 1 Structure The front appearance might differ depending on different models of the Access Controller Here we take the Wi Fi model as an example Figure 1 1 Structure Unit mm inch...

Страница 8: ...ffer depending on different models of Access Controller If you want to connect an external speaker an audio adapter cable is required The load capacity of type C port is 5 V 500 mA 2 2 Installation Re...

Страница 9: ...3 Installation Height Figure 2 2 Installation height requirement Ambient Illumination Requirements Figure 2 3 Ambient illumination requirements...

Страница 10: ...nt and turnstile mount please refer to user s manual of corresponding devices 2 3 1 Wall mount Step 1 According the hole s position of the bracket drill four holes and one cable outlet in the wall Put...

Страница 11: ...e bracket to the 86 case with two screws Step 3 Wire the Access Controller For details see 2 1 Wiring Step 4 Use two screws to fix the back cover to the Access Controller Step 5 Fix the Access Control...

Страница 12: ...et a password and email address for the admin account You can use the admin account to log in to the main menu screen of the Access Controller and the web interface Figure 3 1 Initialization If you fo...

Страница 13: ...3 2 New user Table 3 1 New user description Parameter Description User ID Enter the user ID The ID can be numbers letters and their combinations and the maximum length of the user ID is 32 characters...

Страница 14: ...rd and then the card information will be read by the Access Controller You can set the registered card as the duress card and then an alarm will be triggered when a duress card is used to unlock the d...

Страница 15: ...nd an email address before logging in to the web interface for the first time Step 1 Open a web browser and go to the IP address the default address is 192 168 1 108 of the Access Controller You can l...

Страница 16: ...o to the IP address of the Access Controller Figure 4 2 Login Step 2 Enter the user name and password The default username of administrator is admin and the password is the one you set during initiali...

Страница 17: ...peration The Access Controller can function as VTO to realize intercom function Prerequisites The intercom function is configured on the Access Controller and VTO Procedure Step 1 On the standby scree...

Страница 18: ...ode that is 2 cm 2 cm 5 cm 5 cm and less than 512 bytes in size Access Controller without QR code scanning module Place the printed QR code at a distance of 30 cm 50 cm away from the lens of the Acces...

Страница 19: ...fingerprint scanner Do not put the fingerprint sensor in a place with intense light high temperature and high humidity If your fingerprints are unclear use other unlocking methods Fingers Recommended...

Страница 20: ...14 Appendix Figure 3 3 Wrong placement...

Страница 21: ...wise backlight and direct sunlight might influence face recognition performance of the access controller During Registration You can register faces through the Access Controller or through the platfor...

Страница 22: ...nition do not keep your face too close to or too far from the camera Appendix Figure 4 2 Head position Appendix Figure 4 3 Face distance When importing face images through the management platform make...

Страница 23: ...room and cabinet and implement well done access control permission and key management to prevent unauthorized personnel from carrying out physical contacts such as damaging hardware unauthorized conn...

Страница 24: ...we suggest that you check online users regularly to see if the device is logged in without authorization Check equipment log By viewing the logs you can know the IP addresses that were used to log in...

Отзывы: