extinguish, restart power switch. (Voltage adjustment knob must be
turned to the minimum or output voltage less than the limited
voltage.)
(9)
Attention:
Don't start power switch with the load. Otherwise, easy
to damage DC Power Supply and the load. When the load current
more than 10A,Please use the rear output terminal. When use large
current, wiring terminal and output line must tighten. Otherwise,
wiring terminal will be damaged caused by connecting the big
resistance leading to fever.
4
、
Repair
4-1 Fuse replacement:
If fuse is burnt out, the power supply will stop working. If such
case occurs, its cause must be found and corrected. Use same type
fuse replacement. Do not open the fuse box, unless problem occurs.
4-2 Repair:
If the interior of the power supply is burn out, it must be repaired by
professional maintenance personnel or by the manufacturer through
the distributor. Do not repair it by yourself for the safety reason.
1
、
Summary
RXN-3020D
、
JPS-3020D
、
RXN-3030D
、
JPS-3030D are single output
power supply.RXN-302D(A)-
II、
JPS-302D-II
、
MPS-3002L-3
、
RXN-303D(A)-
II、
JPS-303D-II
、
MPS-3003L-3
、
RXN-305D(A)-
II、
JPS-305D-II
、
MPS-3005L-3
、
RXN-3010D(A)-I
I、
JPS-3010D-II
、
MPS-3010L-3 are three-output power supply, collectively referred to as
high precision constant current, constant voltage DC Linear Power
Supply .Characterized by high precision and strong reliability. And the
three-output power supply with auto tracing, auto series and parallel
operation.
KXN-3050D
、
KXN-3060D
、
…KXN-30010D are high efficiency
constant current, constant voltage DC Switching Power Supply. This
series DC Power Supply feature is strong ability to load and work for
low failure rate. Also they with the over-voltage protection,
over-temperature protection, over-load protection, over-current
protection functions.(work efficiency
≥
86%)
RXN
、
JPS
、
MPS
、
KXN series constant voltage constant current DC
Power Supply design for technology product development, laboratory,
junior college, electronic production line and communications industry.
The technical parameters please see the table.
Caution:
KXN Series are Switching Power Supply. Internal
have high-pressure circuit. Not professional
maintenance personnel must not repair, lest produce
danger.
1