background image

10

ASSEMBLY GUIDE

6. Programmable Remote Control Operating Instructions

The following actions should only be performed by properly trained personnel.

If one or more motors are changed in a system, the control box must be reset to factory settings and a manual reset 

has to be performed!

6.8 Lock or unlock the programmable remote control

Follow the instruction below to lock or unlock the programmable remote control.
• 

Press the “S” and up button (▲) and hold for five seconds.

• 

The display will show “Loc” which means the remote control is now locked.

• 

Press the “S” and down button (▼) and hold for five seconds.

• 

The display will show the height which means the remote control is now unlocked.

6.9 Reset control unit to factory settings

Follow the instructions below to use a configured control unit on another identical electric height adjustable frame or to reset the control 
unit to its original factory settings.
• 

Press the up and down button (▼ and ▲) and hold for ten seconds.

• 

The control unit will “bi” and flash “000”.

• 

Press the down button (▼) until the display shows the height of the desktop. The control unit has now been reset to the original 
factory settings.

6.7 Run automatically with memory position.

Follow the instructions below to change the run automatically with memory position function on or off.
• 

Within the setting menu choose “S – 6”.

• 

Press the “S” button to enter the setup menu.

• 

Press the up or down button (▼ or ▲) to choose the desired setting. “0” means on , “1” means off. 

• 

Press the “S” button to finish the setup.

Содержание e-ZGO 20 Series

Страница 1: ...1 ASSEMBLY GUIDE Rev 01 2021 04 27 ENGLISH e ZGO Series 20 21...

Страница 2: ...ge the displayed desktop position cm or inch 5 5 Saving a desktop position 5 6 Adjusting the desktop to a saved position 5 7 Reset control unit to factory settings 5 8 Changing the desktop height disp...

Страница 3: ...face or it will not be steady Never exceed the maximum load capacity on the adjustable frame Please check the load capacity in Section 7 Specification The control unit is only used for specified linea...

Страница 4: ...on End Pipe 2 Pcs Gear Connection 1Pcs Connection Cable 1 Pcs Left Leg 1 Pcs Leg with Motor 1Pcs Power Cable 1 Pcs Feet 2 Pcs Frame 1 Pcs Remote Control 1 Pcs M6x12 4 Pcs M6x8 4 Pcs ST 4 8x16 6 Pcs M3...

Страница 5: ...ue 6nm M10 Screw s max torque 6nm Tapping screws is hand tightening only 4 2 Assembly Step by Step M6x12 Step 3 Mount the End Pipe to leg as illustrated above M6X8 M6X25 Step 2 Assemble the Leg and Fr...

Страница 6: ...ve Step 5 Loosen the Gear Connection rotating nut as illustrated above ST 4 2X16 Step 9 Mount the Control Unit as illustrated above ST 4 8x16 Step 7 Mount the Frame and End Pipe to the Table top as il...

Страница 7: ...the desk to the lowest height as explained below before proceeding Press button and keep pressing the button until the desktop has reached the lowest position programmed desktop position Press button...

Страница 8: ...frame to any position in the lower half to deactivate the container stop Move the frame to any position in the upper half to deactivate the shelf stop Do so by pressing the or button until you reach t...

Страница 9: ...ress the up or down button or to choose the desired setting 0 means G sensor close 1 means G sensor least sensi tive 8 means G sensor most sensitive Press the S button to finish the setup 6 6 Changing...

Страница 10: ...remote control is now unlocked 6 9 Reset control unit to factory settings Follow the instructions below to use a configured control unit on another identical electric height adjustable frame or to re...

Страница 11: ...f movement is only possible downwards Replace Control Unit Replace the Remote Control Replace the Leg Legs only operating in one direction Possible Cause Remedy Power Cable is not connected Remote Con...

Страница 12: ...again E06 Main power start did not succeed lower than 20V Replace the main power supply or check the main power cable E07 Protect when the main power supply is running lower than 20V Power up again E0...

Страница 13: ...duce load E40 Controller drop line in series Check the cable E41 Error in the series signal Check the cable or replace the controller E42 Memory error Replacing the controller E43 Disable sensor error...

Отзывы: