7
Select a well-ventilated location sheltered from direct sunlight.
Install vertically or tilted backward by a maximum of 15°. The device must
not be installed with a sideways tilt. The connection area must point
downwards. Refer to Figure 3.3-1.
Figure 3.3-1
15¡ ã
In order to achieve optimal performance, the ambient temperature should
be less than 45 °C.
For the accessibility of monitoring the LED lights and possible
maintenance activities, please install the inverter at eye level.
Inverters should NOT be installed near flammable and explosive items.
Any strong electro-magnetic equipment should be kept away from the
installation site.
The product label and the warning symbol must be visible after installation.
Please avoid direct sunlight, rain exposure, or snow accumulation when
locating the installation point.
direct sunlight
rain exposure
snow lay up
Figure 3.3-2
no direct sunlight no rain exposure no snow lay up