Description of minor errors of the EHR-B electro-hydraulic system
F18N109
Flashing combination of
the diagnostic LED (7).
Error location
Possible cause of the error
Long
pause
No.
of
flashes
Short
pause
No.
of
flashes
3x
1x
Right dynamometric pin
(A)
Faulty dynamometric pin
3x
2x
Left dynamometric pin (A) Faulty contact or interrupted conductor of the
dynamometric pin
Short-circuit of the dynamometric pin
conductor
Possible overloading of the dynamometric
pin
3x
4x
Lowering speed control
(3)
Faulty potentiometer of the control (3)
Faulty contact or interrupted conductor of the
control
3x
6x
Control setting switch (6) Faulty potentiometer of the switch (6)
Faulty contact or interrupted conductor of the
switch
ELECTRO-HYDRAULIC SYSTEM
156
Содержание FORTERRA HSX 120
Страница 1: ...FORTERRA HSX 120 130 Tractor is Zetor Since 1946 140 OPERATOR S MANUAL 04 2020...
Страница 3: ...2...
Страница 93: ...NOTES 92...
Страница 125: ...NOTES 124...
Страница 131: ...NOTES 130...
Страница 163: ...NOTES 162...
Страница 179: ...Fuse panel B Tractors without light controller only FHSXS5N010 ELECTRIC INSTALLATION 178...
Страница 181: ...Fuse panel B Tractors with light controller only FHSXS5N008 ELECTRIC INSTALLATION 180...
Страница 195: ...NOTES 194...
Страница 225: ...NOTES 224...
Страница 230: ...229...
Страница 232: ...www zetor com zetor zetor com Made in EU...