98
ELECTRO-HYDRAULIC SYSTEM
F_02_174
DESCRIPTION OF MINOR ERRORS OF THE EHR-B ELECTRO-HYDRAULIC SYSTEM
Flashing combination of
the diagnostic LED (7).
Long pause
No. of
flashes
Short pause
No. of
flashes
Error location
Possible cause of the error
3x
1x Right dynamometric pin (A)
Faulty dynamometric pin
3x
2x Left dynamometric pin (A)
Faulty contact or interrupted conductor of the dynamometric
pin
Short-circuit of the dynamometric pin conductor
Possible overloading of the dynamometric pin
Faulty potentiometer of the control (3)
3x
4x Lowering speed control (3)
Faulty contact or interrupted conductor of the control
Faulty potentiometer of the switch (6)
3x
6x Control setting switch (6)
Faulty contact or interrupted conductor of the switch