background image

 

1.5

 

Delivery scope  

Delivery scope of digital inclinometers is specified in

 Table 1.4

Table 1.4 Delivery scope of ZET 7x54

 

#

 

Item 

 

Quantity

 

Tiltmeter ZET 7х54 

1 pc 

Adjusting plate for ZET 7х54 

1 pc 

Plug for the cable FQ14-4TJ-7 

2 pcs 

CD with ZETLAB SENSOR software 

1 pc 

Product certificate 

1 pc 

User manual

2

 

1 pc 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

a set of Products can be provided with a single copy of the Document 

Содержание ZET 7054

Страница 1: ...DIGITAL INCLINOMETER ZET 7054 ZET 7154 USER MANUAL LLC ETMS...

Страница 2: ...ntacts labelling 9 2 4 Digital inclinometers mounting 10 2 5 Establishing measuring network connection diagram 11 3 PARAMETERS CONFIGURATION PREPARATION 12 3 1 Connection of digital inclinometers 12 3...

Страница 3: ...ng installation start up and pre starting procedure can be conducted by the User or by a representative of the organization performing technical maintenance of the equipment as per provisions of the A...

Страница 4: ...tilt angle of industrial residential and municipal facilities The inclinometers can be easily installed on the controlled facility without the need to connect any external primary transducers 1 3 Ope...

Страница 5: ...acitance transducer Data refresh rate Hz 1 Data interface RS 485 CAN 2 0 Power supply voltage V 9 24 Consumed power W 0 5 Protections class Industrial version Explosion proof version IP65 IP67 Dimensi...

Страница 6: ...Delivery scope of ZET 7x54 Item Quantity 1 Tiltmeter ZET 7 54 1 pc 2 Adjusting plate for ZET 7 54 1 pc 3 Plug for the cable FQ14 4TJ 7 2 pcs 4 CD with ZETLAB SENSOR software 1 pc 5 Product certificate...

Страница 7: ...digital inclinometer industrial version General dimensions and mounting dimensions of inclinometer industrial version are specified in Figure 2 2 Figure 2 2 Mounting dimensions of digital inclinomete...

Страница 8: ...rnal view of explosion proof product version of the inclinometer is shown in Figure 2 3 Figure 2 3 External view of explosion proof product version of the inclinometer Mounting dimensions of the incli...

Страница 9: ...4 V 2 RS 485 line B or DATA CAN 2 0 line H 3 RS 485 line A or DATA CAN 2 0 line L 4 GND Figure 2 5 Contacts labelling for connection to measuring network Connectors FQ14 4ZK S are intended for connect...

Страница 10: ...te has four holes with 5 5 mm diameter for mounting on the controlled surface Figure 2 6 Mounting of ZET7x54 with the use of adjustment plate The selected range of tilt angle measurements for measurin...

Страница 11: ...connected to the PC by means of interface converter Table 3 1 Figure 2 7 displays the measuring network based on digital transducers ZET 7154 Figure 2 7 Variants of establishing measuring lines with...

Страница 12: ...rogram Device manager Configuration of digital transducers is conducted in the program Device manager available in the Service menu of ZETLAB control panel Figure3 1 Figure 3 1 ZETLAB panel The left s...

Страница 13: ...Please note that it is necessary to set unique address for every device in the measuring network in the section Address node from 2 up to 63 of the Information tab In order to secure normal operation...

Страница 14: ...splays the measured value of the channel at the moment of tab activation Refresh rate Hz Depends on the value selected for the parameter Conversion frequency of the Sensor tab Measurement unit Corresp...

Страница 15: ...15 Figure 4 1 shows an example of the tab Axis Figure 4 1 The tab Axis X...

Страница 16: ...Exponential moving average order No 256 Number of averaged counts Exponential moving average Yes 0 001 1 Ratio for EMA filter which is calculated by the formula DMAt EMAt 1 DMAt 1 The more is the valu...

Страница 17: ...17 Figure 4 2 shows an example of Settings tab Figure 4 2 Settings tab...

Страница 18: ...tatus Yes off on If the Offset option is disabled the values by X and Y axes are set to zero The offset value is displayed in the field Displacement by axis of the Settings tab As the Offset function...

Страница 19: ...you can visually control the stabilization process with the use of the program multichannel oscilloscope from the scope of ZETLab software Then select the option On and save the settings again The dig...

Страница 20: ...nometers 5 1 Checksum control The Metrology tab contains digital ID of the software The field Digital ID should have the value 81964459B471A73B777AD09E1FD45773 Figure 5 1 shows an example of Metrology...

Страница 21: ...hronization quality while inclinometers ZET 7054 have only the function of data quality control Figure 5 2 shows an example of the program Synchronization control Figure 5 2 Example of the program Syn...

Страница 22: ...5 times The tab Testing Figure 5 3 is used for metrological self check performance Figure 5 3 Testing tab Self check procedure sequence 1 Mount the inclinometer at a horizontal surface 2 Enter the me...

Отзывы: