ZETA Light Sensor

Содержание OPZ1ZT92

Страница 1: ...OPZ1ZT92 1 ZETA Light Sensor...

Страница 2: ...e Disclaimer This specification is preliminary and is subject to change at any time without prior notice ZiFiSense assumes no responsibility for any errors contained herein ZiFiSense is not responsibl...

Страница 3: ...escription 4 2 Applications 4 3 Features 4 4 Specifications 5 5 Packing List 5 6 Installation 6 6 1 Screw 6 6 2 Adhesive 3M 8 6 3 Cable Ties 9 Use of Device 12 8 1 Steps for usage 12 8 2 Support funct...

Страница 4: ...e to quantify the illuminance value and provide alarm signals if the threshold values are exceeded 2 Applications Room lighting detection lamp aging detection 3 Features Wireless transmission Battery...

Страница 5: ...rical Features Power supply Battery 2 ER14505 Battery capacity 2 2700 mAh Stand by current 10 A Working current 70 mA Physical Features Size 66 55 36 mm Enclosure material ABS Waterproof level IP30 An...

Страница 6: ...g screw M3 20 2 device 2 4 expanded plastic pipe 2 3 Percussion drill 4 drill bit hammer 1 4 slotted screwdriver cross screwdriver 1 6 1 2 Installation instructions Open the device case Use a slotted...

Страница 7: ...re the device in the mounting position Power on Insert the power plug into the upper power socket install two 14505 batteries remove the insulation sheet for the existing battery and close the upper c...

Страница 8: ...2 2 Installation instructions Installation position Select a flat mounting position and clean it up Open the device case Use a slotted screwdriver to open the top cover from the bottom edge Power on I...

Страница 9: ...m of the 3M adhesive and install the device to the specified position 6 3 Cable Ties 6 3 1 Auxiliary material No Materials Quantity 1 Metal cable ties 5 300mm 2 2 Slotted screwdriver utility knife 6 3...

Страница 10: ...OPZ1ZT92 10 Fixation Pass the 2 cable ties through the device and secure to the installation rod opening Installation position...

Страница 11: ...OPZ1ZT92 11 Power on Insert the power plug into the upper power socket install two 14505 batteries remove the insulation sheet for the existing battery and close the upper cover power socket...

Страница 12: ...e 0 255 minutes default value 0 which means the alarm is reported only once Set Query Alarm Threshold Set the upper lower alarm threshold for alarms Once the detected value exceeds the set alarm thres...

Страница 13: ...rsion number of the current sensor 8 Common faults and handling Ensure ZETA signal coverage Ensure that the device is powered on and the ZETA network device management platform can observe that the ZE...

Страница 14: ...the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference...

Страница 15: ...OPZ1ZT92 14...