FYREYE MKII ADDRESSABLE SOUNDER CONTROL MODULE WITH ISOLATOR - INSTALLATION GUIDE

Faultfinding

Problem

Possible Cause

No response or missing

Incorrect address setting
Incorrect loop wiring

Fault condition reported

IIncorrect address setting
Incorrect wiring of sounder zone or fault input
Faulty sounder
Local supply faulty or polarity incorrect
Fuse blown on sounder PCB

Sounders do not operate

Incorrect wiring
Fuse blown on sounder PCB

Incorrect cause and effect programming

Faulty sounder
Panel Fault

Sounders operate continuously

Incorrect sounder zone wiring

Analogue value unstable

Dual address
Loop data fault, data corruption

 

0905

Zeta Alarms Limited,

72-78 Morfa Road, Swansea SA1 2EN

14

GLT-234-DoP-1

EN54-18: 2005

EN54-17: 2005

Fire detection and fire alarm systems – Input/Output Devices

Fire detection and fire alarm systems – Short Circuit Isolators

Zeta Addressable Sounder Control Module with Isolator

ZASC-MI

Intended for use in fire detection and fire alarm systems in and around buildings

Response delay (response time) - PASS

Performance under fire conditions - PASS

Operational reliability - PASS

Durability of operational reliability: temperature resistance - PASS

Durability of operational reliability; vibration resistance - PASS

Durability of operational reliability; humidity resistance - PASS

Durability of operational reliability; corrosion resistance - PASS

Durability of operational reliability; electrical stability - PASS

Содержание FYREYE MKII ZASC-MI

Страница 1: ...up Note the input voltage should provide adequate current to operate the ZASC MI in addition to operating the connected alarm load Model No ZASC MI Fyreye MkII Addressable Sounder Control Module With...

Страница 2: ...o 012 Author NRP Jones Date 10 05 2021 Page 2 FYREYE MKII ADDRESSABLE SOUNDER CONTROL MODULE WITH ISOLATOR INSTALLATION GUIDE Wiring Details All wiring terminals will accept solid or stranded cables u...

Страница 3: ...On Current Ext 32V 9 5mA Plus Sounder Load Sounder Output Rating 500 mA Isolating Current 7 3mA Sounder End of Line 10K tolerance 7 5K to 15K Operating Temperature 10 C to 55 C Max Humidity 95 RH Non...

Страница 4: ...OFF OFF OFF ON ON 61 OFF ON OFF OFF OFF OFF ON ON 62 ON OFF OFF OFF OFF OFF ON ON 63 OFF OFF OFF OFF OFF OFF ON ON ADDRESS SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 64 ON ON ON ON ON ON OFF ON 65 OFF ON ON ON...

Страница 5: ...OFF OFF OFF 248 ON ON ON OFF OFF OFF OFF OFF 249 OFF ON ON OFF OFF OFF OFF OFF 250 ON OFF ON OFF OFF OFF OFF OFF 251 252 253 254 255 ADDRESS SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 128 ON ON ON ON ON ON ON OF...

Страница 6: ...000000 Step 2 Connect leads to LOOP IN and LOOP IN as shown below Step 3 Follow the procedure as described in the handheld programmer manual NOTE When a device is soft addressed as above the address C...

Страница 7: ...er is connected correctly Input Illuminated when no external fault signal present Functional Test Data Command Bit Function Input Bit Function 3 Not Used 3 Not Used 2 Not Used 2 Not Used 1 PULSED MODE...

Страница 8: ...value unstable Dual address Loop data fault data corruption 0905 Zeta Alarms Limited 72 78 Morfa Road Swansea SA1 2EN 14 GLT 234 DoP 1 EN54 18 2005 EN54 17 2005 Fire detection and fire alarm systems I...

Отзывы: