Temperature range:

   -10° to +40°C.   

Sensitivity:    

50ppm within 90 minutes

 

       100ppm 

within 

30 

minutes 

       300ppm 

within 

minutes 

 

Audible Alarm Outpu

t:  85dB at 3m 

 
All alarms are calibrated, tested and design to meet the stringent 
performance requirements of the latest European standard for 
domestic gas alarms - BS EN50291:2001 
 
The Alarm is calibrated at the factory and does not need 
recalibration. Do not tamper with the inside of the case or electric 
shock or malfunction may occur.   
 
No user maintenance or adjustment is required.   

 

WARNING AND LIMITATION 

This detector may not alarm at low carbon monoxide levels. The 
Occupational Safety and Health Association (OSHA) has 
established that continuous exposure levels of 30 ppm should not 
be exceeded in an 8 hours period. Individuals with a medical 
problem may consider more sensitive detection devices. 

The CO gas detector is not suitable as a smoke or fire detector. 
This detector is not suitable to install in a hazardous location, as 
defined in the National Electrical Code. 

This detector will not work without power. The Carbon Monoxide 
Detector will not work if the power supply is disconnected or cut off 
or remove the batteries for any reason. Additionally, carbon 
monoxide must reach the detector for the proper performance of 
CO gas detection. 
Carbon monoxide detectors may wear out because they contain 
electronic parts that fail at any time. Test your detector at least 
every week (see the section "TESTING YOUR DETECTOR"). 

SERVICE OR REPAIR INFORMATION 

For service or repair, return your Zeta CO 200 Carbon Monoxide 
Detector intact, stating the reason for return and details of any 
fault, to the distributor who supplied the product.   