13

MAINTAINING / 

TESTING YOUR 

DETECTOR

Maintenance

Your detector will alert you to potentially 

hazardous CO concentrations in your home 

when maintained properly. To maintain your 

Zeta detector in proper working order, and to 

ensure that the sensor will last for the lifetime of 

the product, it is recommended that you:

• Test the sounder, batteries and circuitry of 

your detector once per week by pressing 

and holding the Test/Reset button for 1 

second (see page 9)

• Perform the Sensor Test annually  

(see page 9)

• Keep the detector free of dust by gently 

vacuuming the case with a soft brush 

attachment when required.

To prevent the possibility of contaminating the 

sensor in your detector and thus affecting its 

reliability:

• Never use cleaning solutions on your 

detector. Simply wipe with a slightly damp 

cloth

• Do not paint the detector
• Do not spray aerosols on or near the 

detector

• Do not use any solvent based products 

near the detector

• Move the detector to a safe location and 

store in a plastic bag before painting, wall 

papering, or performing any other activities 

using substances that emit strong fumes. 

Remember to remove it from the bag and 

return the detector to its original location 

when these activities are finished

Failure of any test should be reported to 

the  technical  support  line  (see  page  19  for 

contact details).

Do not attempt to repair your CO detector. 

Do not remove any screws or open the main 

casing of your detector. Any attempt to do so 

may cause malfunction and will invalidate the 

warranty.

Содержание ZD-CO-9B

Страница 1: ...CARBON MONOXIDE POISONOUS GAS ALARM ZD CO 9B User Manual...

Страница 2: ...ATURES UNDERSTANDING THE PRODUCT S INDICATORS MAINTAINING TESTING YOUR DETECTOR WHAT TO DO IN THE EVENT OF AN ALARM USEFUL NUMBERS TECHNICAL INFORMATION DISPOSAL 7 YEAR WARRANTY RETURNS PRODUCT RANGE...

Страница 3: ...he latest additions to our product range Zeta Alarm Systems provide some of the most technologically advanced carbon monoxide detectors in the world FEATURES An advanced electrochemical sensor designe...

Страница 4: ...y be related to CO poisoning which all household members should be made aware of Mild Exposure Slight headache nausea vomiting fatigue often described as flu like symptoms Medium Exposure Severe throb...

Страница 5: ...o not use this carbon monoxide detector on an intermittent basis or as a portable detector for trying to trace one source of the spillage of combustion products from fuel burning appliances or from ch...

Страница 6: ...he detector be installed Ideally an apparatus should be installed in every room containing a fuel burning appliance Additional apparatus may be installed to ensure that adequate warning is given for o...

Страница 7: ...st be observed If the apparatus is located on a wall it should be located close to the ceiling it should be located at a height greater than the height of any door or window it should be at least 150m...

Страница 8: ...tector is installed on the wall To mount on a wall or ceiling Please ensure that you use the screws provided as they were chosen specifically for use with this product Use template below for guidance...

Страница 9: ...page 16 for recommended batteries making sure the batteries are the correct way round Use of batteries other than those recommended by Zeta Alarm Systems may have a detrimental effect on the detector...

Страница 10: ...tteries and circuitry Allow you to test the sensor by introducing a source of CO into the detector see Testing The Sensor below Silence the loud 85dB sounder during an alarm only possible when current...

Страница 11: ...nse sticks are used as they are cheap and readily available Read all steps thoroughly before attempting to test your the sensor Step 1 If the detector is wall or ceiling mounted unhook the detector fr...

Страница 12: ...Power LED will no longer flash green every second but will revert to flashing once every minute as the detector will go back to normal operating mode It may take up to two minutes of exposure to the s...

Страница 13: ...l flash red once every second The Alarm will sound Between 60 and 90 minutes when exposed to 50ppm of CO Between 10 and 40 minutes when exposed to 100ppm of CO Within 3 minutes when exposed to 300ppm...

Страница 14: ...he sensor in your detector and thus affecting its reliability Never use cleaning solutions on your detector Simply wipe with a slightly damp cloth Do not paint the detector Do not spray aerosols on or...

Страница 15: ...f possible that they are turned off Evacuate the property leaving the doors and windows open Ring your gas or other fuel supplier on their emergency number keep the number in a prominent place Write y...

Страница 16: ...solid fuel appliances HETAS Trade association for solid fuel engineers OFTEC Trade association for Oil Fired Appliance engineers NACS National Association of Chimney Sweeps IPHE Institute of Plumbing...

Страница 17: ...dity Range 30 90 RH Weight inc batteries 125 grams 4 4oz Certified to BS EN 50291 2001 WARNING Prolonged exposure to temperatures and humidity outside those stated above will reduce battery and sensor...

Страница 18: ...ide detector to us for disposal For return address see the section on Returns Please include a note confirming the product is being returned for disposal WARNING DO NOT ATTEMPT TO OPEN DO NOT BURN WAR...

Страница 19: ...te of original retail purchase and is not transferable Proof of purchase is required Warranty disclaimers This warranty does not cover damage resulting from accident misuse disassembly abuse or lack o...

Страница 20: ...e phone this is to prevent unnecessary returns that take a longer time to process Alternatively e mail support zetaalarmsystems com If there is a fault that we are unable to resolve then our technical...

Страница 21: ...20 Ref GN0501 R2 NOTES...

Страница 22: ...m Systems Detection House 72 78 Morfa Road Swansea SA1 2EN BS EN 50291 2001 KM 551504 ZD CO 9B GN0501 R2 Technical Support Line 44 0 1792 455 175 Email support zetaalarmsystems com Web www zetaalarmsy...

Отзывы: