19
unless constant supervision is provided.
• WARNING: To reduce the risk of fire, keep textiles, curtains, or
any other flammable material a minimum distance of 1 m from the
air outlet.
2. W
all
Mounting
•
Fix the convector in horizontal position with the air outlet grid upward;
•
This convector is fitted with a double electrical insulation circuit (class II) and therefore does not require earth
connection.
•
This heater must be correctly installed in compliance with the regulations in force in the country of installation.
•
In wet spaces like bathrooms or kitchens, the connection terminal must be installed at least 25 cm above the
floor. The electrical connection to the power supply must also be fitted with a two-pole switch with a minimum
gap between the contacts that allows complete disconnection according to excess voltage III category conditions.
•
The device must be wall-mounted respecting the minimum distances from ceiling, floor and side walls shown in
figure 2. The support bracket must be fixed to the wall respecting the distances indicated in figure 3 and specified
in the following table. Always observe the minimum distances from walls, furniture and/or objects, as indicated
in picture 3.
•
To proceed with the installation:
-
Remove the bracket from the product;
-
Drill 4 holes in the wall respecting the distances indicated in figure 3 and specified in the following table:
MODEL
A
B
C
SIRIO 5
205mm
180mm
357mm
SIRIO 10
290mm
260mm
400mm
SIRIO 15
270mm
480mm
400mm
SIRIO 20
250mm
700mm
400mm
-
Fix the bracket using the wall plugs and screws suitable for the wall type;
-
Verify that the minimum distances previously described are satisfied;
-
Approach the product to the bracket until the lower hooks of the bracket are inserted in the slots on the
rear panel as shown in figure 4;
-
Rotate the upper part of the product towards the wall until it locks, making sure to snap the 2 upper hooks
of the bracket as shown in figure 5;
-
Lock the 2 upper hooks of the bracket using the supplied screws as shown in figure 6.
3. W
heel
Fastening
(
oPtional
)
•
The convector can also be used as a portable product by purchasing the wheels supplied separately.
•
To fix the wheels:
-
check the correct orientation as shown in figure 7;
-
fix each of the 2 supports with the wheels using the screws provided as shown in figure 8. The screws can
be fixed by hand and do not require any tool.
4. c
oMMands
descriPtion
•
The convector is equipped with an on / off button on the right side. When the product is switched off, the internal
electrical components will no longer be under tension.
•
The following controls are integrated on the front of the product (figure 10):