background image

19

unless constant supervision is provided.

•  WARNING: To reduce the risk of fire, keep textiles, curtains, or 

any other flammable material a minimum distance of 1 m from the 

air outlet.

2.  W

all

 

Mounting

• 

Fix the convector in horizontal position with the air outlet grid upward;

• 

This convector is fitted with a double electrical insulation circuit (class II) and therefore does not require earth 

connection.

• 

This heater must be correctly installed in compliance with the regulations in force in the country of installation.

• 

In wet spaces like bathrooms or kitchens, the connection terminal must be installed at least 25 cm above the 

floor.  The electrical connection to the power supply must also be fitted with a two-pole switch with a minimum 

gap between the contacts that allows complete disconnection according to excess voltage III category conditions. 

• 

The device must be wall-mounted respecting the minimum distances from ceiling, floor and side walls shown in 

figure 2. The support bracket must be fixed to the wall respecting the distances indicated in figure 3 and specified 

in the following table. Always observe the minimum distances from walls, furniture and/or objects, as indicated 

in picture 3. 

• 

To proceed with the installation:

 -

Remove the bracket from the product;

 -

Drill 4 holes in the wall respecting the distances indicated in figure 3 and specified in the following table:

 

MODEL

A

B

C

SIRIO 5

205mm

180mm

357mm

SIRIO 10

290mm

260mm

400mm

SIRIO 15

270mm

480mm

400mm

SIRIO 20

250mm

700mm

400mm

 

 

 -

Fix the bracket using the wall plugs and screws suitable for the wall type;

 -

Verify that the minimum distances previously described are satisfied;

 -

Approach the product to the bracket until the lower hooks of the bracket are inserted in the slots on the 

rear panel as shown in figure 4;

 -

Rotate the upper part of the product towards the wall until it locks, making sure to snap the 2 upper hooks 

of the bracket as shown in figure 5;

 -

Lock the 2 upper hooks of the bracket using the supplied screws as shown in figure 6.

3.  W

heel

 

Fastening

 (

oPtional

)

 

• 

The convector can also be used as a portable product by purchasing the wheels supplied separately. 

• 

To fix the wheels:

 -

check the correct orientation as shown in figure 7; 

 -

fix each of the 2 supports with the wheels using the screws provided as shown in figure 8. The screws can 

be fixed by hand and do not require any tool.  

4.  c

oMMands

 

descriPtion

 

• 

The convector is equipped with an on / off button on the right side. When the product is switched off, the internal 

electrical components will no longer be under tension.

• 

The following controls are integrated on the front of the product (figure 10):

Содержание SIRIO 5

Страница 1: ...zitor portabil se recomanda folosirea ocazionala si numai in spatii bine izolate PL Kiedy jest u ywany jako przeno ny Ten produkt jest odpowiedni tylko do sporadycznego u ytku lub do stosowania w dobr...

Страница 2: ...2 min 15cm min 15cm min 15cm min 50cm min 15cm Volume 3 Volume 1 Volume 2 60cm 60cm 2 25m 60cm 1 190mm min 295mm B A min C min 2 3 4...

Страница 3: ...3 click 6 5 7 8...

Страница 4: ...4 9 W 110 5mm 420mm 10 W SIRIO 5 450mm SIRIO 10 650mm SIRIO 15 850mm SIRIO 20 1050mm...

Страница 5: ...ial industrial enviroment in vehicles or on board ships or aircrafts This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental ca pabilitie...

Страница 6: ...attention The air outlet grille gets hot during operation more than 90 C WARNING In order to avoid overheating do not cover the heater Do not hang anything on the heater and do not cover it while it...

Страница 7: ...the installation Remove the bracket from the product Drill 4 holes in the wall respecting the distances indicated in figure 3 and specified in the following table MODEL A B C SIRIO 5 205mm 180mm 357mm...

Страница 8: ...activation status of the functions Comfort Comfort 1 C Comfort 2 C Eco Anti freeze Keypad lock Open window detection Heating in progress Operation mode selection button Special functions button Naviga...

Страница 9: ...use the product for a long time and instead use the on stand by button on the control panel in the event of a short operating interruption of the device This way you will not lose the adjustment setti...

Страница 10: ...s up when the heating element is operating In this mode the open window detection function is available see the FUNCTIONS button ECO mode The convector operates to achieve and maintain the set comfort...

Страница 11: ...ically set the Antifreeze operation mode If a sharp reduction of the ambient temperature is detected during the normal operation of the product the antifreeze mode is automatically activated to reduce...

Страница 12: ...ediate vicinity of the product and may differ from the temperature measured with other instruments in other areas of the room This difference may depend on various factors such as The installation pos...

Страница 13: ...een day setting to time setting Use and buttons to select the current time Press the button to switch between hour setting and minutes set ting Use and buttons to select the current minutes Press the...

Страница 14: ...freeze Press the button to view edit the following day If you wish to copy the settings for one day to another following proceed as follows Select the day you want to copy the settings from and press...

Страница 15: ...nical service centre When replacing the power cable use a 2x0 75mm2 H05RR F or 2x1 00 mm2 H05RR F HAR type This ope ration must be performed by qualified personnel and never by the end user in order t...

Страница 16: ...0 000 kW single stage heat output and no room temperature control no In standby mode elSB 0 162 W Two or more manual stages no room temperature control no with mechanic thermostat room temperature co...

Отзывы: