Technical:
Electrical:
The Switch 6 range is designed to operate on 230V at
50Hz. The unit may not operate satisfactorily outside this
specification.
- Mains Supply Voltage: 230V +/- 10%
- Single or 3 Phase (Star Only)
- Frequency: 45 – 65 Hz
- Channel Rating: 10A
Mechanical:
- Height: 88mm
- Width: 483mm
- Depth: 360mm
- Weight: 7.0kg (15.4lb)
DMX Connections
One male and one female 5 pin XLR connector. Pin
assignment is:
Pin 1
0V
Pin 2
DMX- (RS485 B line)
Pin 3
DMX+ (RS485 A line)
Pin 4
Reserved
Pin 5
Reserved
DMX Indication:
On
DMX dimmer data (start byte of 00)
being received OK.
Flash Fast
DMX data being received, but not
dimmer data (start byte of 00)
Flash Slow
DMX data errors occurring.
Off
No DMX data being received.
Chillinet Connections:
Twin RJ12 connectors. Pin assignment is:
Pin 1
!! Factory use only. Do not connect !!
Pin 2
+12V
Pin 3
CAN-L
Pin 4
CAN-H
Pin 5
0V
Pin 6
!! Factory use only. Do not connect !!
Cooling:
Ambient Temperature: 0 to 40 Degrees Centigrade.
The Switch 6 is cooled by natural convection. An internal
temperature sensor monitors the temperature. A warning,
according to the table below, is shown on the display if the
internal temperature rises above the normal operating
level.
Notes:
Zero 88 Lighting Ltd reserves the right to make changes to
the equipment described in this manual without prior
notice.
This equipment is designed for professional stage lighting
control, and is unsuitable for any other purpose.
It should be used by, or under the supervision of, an
appropriately qualified or trained person.
E&OE. Zero88 Lighting Ltd reserves the right to change
the specification without prior notice.
Manual Stock Number: 7387700
Issue 1.3: March 2007
© Zero 88 Lighting Ltd 2005-2007
Temperature
Main display
<75C
normal
75C-95C
temperature
>95C
“hot”
sensor fault
“err”
WARNING – DO NOT REMOVE THE COVER
WITHOUT FIRST COMPLETELY
DISCONNECTING THE SWITCH 6 FROM THE
MAINS SUPPLY.