SWITCH 6 USER GUIDE   

 

 

Zero88 Lighting Ltd, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K 

Tel: +44 (0) 1633 838088 (24hr Answer Phone) Fax: +44 (0) 1633 867880 

73-877-00                                                       Email: 

[email protected]

 

IM7804Switch6ManualIssue1_3.doc 

www.zero88.com

 

Page 1 of 4 

 
 
 
 
 
 

To Remove The Cover: 

 
Isolate and disconnect the Switch 6 from the mains supply. 
The mains supply terminals are located under the top cover.   
Remove the four screws from the side end plates to lift off the cover. 
 

Connecting The Mains: 

 
The  Switch  6  is  supplied  configured  for  three-phase  operation.  As  shown  in  the  diagram 
below; 
 

 

 

Single Pole Breakers 

 

 

 

Neutral Disconnect Breakers 

 
 
 
A linking bar (part 00-380-00) can be supplied to order, for single-phase operation 
 

Mounting/Installation: 

 
The Switch 6 has side brackets for mounting in a standard 19” rack/case. 
 

Ventilation: 

 
The Switch 6 is cooled by natural convection. In order to prevent the unit from overheating, 
DO NOT block the vents located on either side of the unit. 

WARNING! 

DO NOT REMOVE THE COVER WITHOUT FIRST 

COMPLETLEY DISCONNECTING THE SWITCH 6 FROM THE 

MAINS SUPPLY 