background image

DEMUX24 USER GUIDE 

 

 

Zero88 Lighting Ltd, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K      

www.zero88.com

 

Tel: +44 (0) 1633 838088 (24hr Answer Phone)      Fax: +44 (0) 1633 867880      Email: 

[email protected]

 

73-402-00    IM7752Demux24ManualIssue2.doc 

 

Page 3 of 3 

Resetting The Demux24:  
 
Press  the  ‘Up  &  Down’  Arrows  until  the  display  shows 

“rset”

.    Press  ‘Enter’  to  confirm.  The  display  will  flash 

briefly to confirm this action.  The Demux24 will be reset 
to its default settings, shown in the table below: 
 

Set Up Parameter 

State  

Manual Control 

Levels 

All Off 

DMX Addresses 

Block patch at 001 

DMX Fail Mode 

Hold Last State 

Memory 

Memory Cleared 

Preheat 

Off (0%) for all 

channels 

Law 

Normal law for all 

channels 

Polarity 

Positive for all output 

sockets 

DMX termination 

Disabled 

 
 
Firmware Version: 
 
To  identify  which  version  of  firmware  is  loaded  in  the 
Demux24

,  press  the  ‘Up  &  Down’  Arrows  until  the 

firmware  version  is  shown  in  the  display 

(e.g.  01.02)

 

Press  and  hold  the  ‘Enter’  button  for  1s,  and  the 
Demux24

’s CPU serial number will be displayed. Press 

the ‘Enter’ button again to return to the version display. 
Note that the firmware version will also be shown briefly 
on start up. 
 
 

Technical: 
 

 

 
 
 
 
 
 

Electrical: 
The  Demux24  is  designed  to  operate  on  the  following 
mains  input  specification.  The  Demux24  may  not 
operate satisfactorily outside this specification. 
 
 - Mains Supply Voltage: 85-264V AC 
 - Frequency: 47 

– 63 Hz 

 - Single Phase CEE22 inlet connector 
 
 
Mechanical: 
 
 - Height: 44mm 
 - Width: 483mm 
 - Depth: 128mm 
 - Weight: 3.0kg (6.6lb) 
 
 

Analogue Output Connections 
 
 -  Four  8-pin  ring-locking  DIN connectors,  six  channels 
each. 
 -    Short  circuit  proof,  all  channels  capable  of  5mA, 
diode output. 
 - Positive / Negative polarity by software selection. 
 - Any dimmer supply not used. 
 - Pin assignment is: 
 
Pin 1 

Channel 1   (7,  13,  19) 

Pin 2 

Channel 2   (8,  14,  20) 

Pin 3 

Channel 3   (9,  15,  21) 

Pin 4 

Channel 4   (10, 16, 22) 

Pin 5 

Channel 5   (11, 17, 23) 

Pin 6 

Channel 6   (12, 18, 24) 

Pin 7 

Not connected 

Pin 8 

0V 

 
 
DMX Connections 
 
One  male  and  one  female  5 pin  XLR connector.  Opto-
isolated. Pin assignment is: 
 
Pin 1 

0V 

Pin 2 

DMX- (RS485 B line) 

Pin 3 

DMX+ (RS485 A line) 

Pin 4 

Reserved 

Pin 5 

Reserved 

 
 
DMX Indication: 
 

On 

DMX dimmer data (start byte of 
00) being received OK. 

Flash 

Fast 

DMX data being received, but 
not dimmer data (start byte of 
00) 

Flash 

Slow 

DMX data errors occurring. 

Off 

No DMX data being received. 

 
 
 
 
 

Notes: 

 
Zero 88 Lighting Ltd reserves the right to make changes to the 
equipment described in this manual without prior notice. 
 
This  equipment  is  designed  for  professional  stage  lighting 
control, and is unsuitable for any other purpose. 
 
It  should  be  used  by,  or  under  the  supervision  of,  an 
appropriately qualified or trained person. 
 
E&OE.  Zero88  Lighting  Ltd  reserves  the  right  to  change  the 
specification without prior notice. 
 
Manual Stock Number: 7340200 
 
Issue 2.0: September 2006  
 
© Zero 88 Lighting Ltd 2006 

WARNING 

DO NOT REMOVE COVERS WITHOUT FIRST 

COMPLETELY DISCONNECTING THE 

DEMUX24 FROM THE MAINS SUPPLY. 

 