Memories: 
 
The  Demux24  will  store  12  memories  for  stand  alone 
operation,  these  can  only  be  re-called  if  there  is  no 
DMX present.   
 

1.  Set-

up  the  scene  using  the  ‘

Manual

’  control 

function or a DMX controller. 

 

2.  Select 

„Memory‟

 

using the ‘Mode’ button. 

 
Using  the  ‘Up  &  Down’  Arrows  select  the  required 
memory number and press the ‘Enter’ button to confirm.  
A ‘p’ should appear next to the memory to signify that it 
has been programmed. 
 
Holding both the ‘Up & Down’ Arrows for 1 second will 
clear the selected memory. If these buttons are held for 
5 seconds, ALL memories will be cleared. 
 
 
Preheats: 
 
Preheats  can  be  selected  on  a  per  channel  or  all 
channel  basis.  The  preheat  level  is  preset  to  5%  and 
cannot be adjusted. 
 
Select 

„Preheat‟

  by  cycling  through  the  modes  using 

the ‘Mode’ button. 
 
Select required channel or ‘A’ for all channels, using the 
‘Up & Down’ Arrows and press ‘Enter’, to confirm.   
 
Now select on/off using the ‘Up & Down’ Arrows.  Press 
‘Enter’ to confirm and return to the channel selection. 
 
 
Output Laws: 
 
Four  output  laws  are  available,  which  can  be  selected 
per channel. 
 
Select 

„Law

’ mode using the ‘Mode’ button.  Using the 

‘Up & Down’ Arrows select the channel required, or ‘A’ 
for  all  channels.  Press  ‘Enter’  to  confirm.    Now  select 
the  law  you  require,  again  using  the  ‘Up  &  Down’ 
Arrows  and  press  ‘Enter’  to  confirm  and  return  to  the 
channel selection. 
 

Output Law  

Main Display 

Normal 

Switch 

Linear 

Invert 

in 

 
Note  that  the  Invert  law  is  different  to  the  voltage 
polarity  option  described  below.  The  Invert  law  results 
in  the  output  being  at  full  scale  voltage  (either  positive 
or negative) for a DMX input value of 0%, and 0V for a 
DMX input value of 100%. 
 
 

Polarity: 
 
 
 
 
 
 
 
 
Each  output  socket  can  be  set  to  positive  or  negative 
voltage polarity.  
 
Select 

„Polarity‟

 

mode using the ‘Mode’ button.  Using 

the  ‘Up  &  Down’  Arrows  select  the  socket  required,  or 
‘A’ for all sockets. Press ‘Enter’ to confirm.  Now select 
the polarity (

„Pos‟

 or 

„Neg‟

) you require, again using the 

‘Up  &  Down’  Arrows  and  press  ‘Enter’  to  confirm  and 
return to the socket selection. 
 
 
 

Super User: 

 
The  Demux24  has  a  number  of  hidden  functions, 
located  in  the  Super  User  Menu.    The  super  user 
menu’s  can  only  be  accessed  from  the 

Default 

mode 

(No LEDs Lit).  To enter Super User press and hold the 
‘Up  &  Down’  Arrows  together  and  press  and  hold  the 
‘Mode’  button  for  5  seconds.    All  the  mode  LEDs  will 
flash to indicate the Demux24 is in super user mode. 
 
The ‘Up & Down’ Arrows are used to cycle through the 
various  super  user  functions.  Pressing  the  ‘Mode’ 
button at any point will revert to normal operation.  If no 
buttons are pressed after 20 seconds the Demux24 will 
automatically revert to normal operation. 
 
 
Lock/Unlock  
 
Press  the  ‘Up  &  Down’  Arrows  until  the  display  shows 

“LOC”. 

Press  ‘Enter’  to  confirm  this  action.    The 

Demux24  will revert to the Default mode. Pressing the 
‘Mode’  button  now  will  only  cycle  between 

Manual 

Control

 and 

Default 

Mode. 

 
If  Super  User  is  entered  when  the  Demux24  is  locked, 
only  the  unlock  function  will  be  available.    The  display 
will  show 

“UNL”.

  To  unlock  the  Demux24,  press  and 

hold the ‘Enter’ button for 5 seconds.  The Demux24 will 
unlock  and  exit  super  user  returning  to  the  Default 
mode. 
 
 
DMX Termination: 
 
Press  the  ‘Up  &  Down’  Arrows  until  the  display  shows 

“ter”

.  If the Demux24 is terminated a dot will appear at 

the  bottom  of  the  last  segment.    Pressing  the  ‘Enter’ 
button will toggle between the two states. 
 
 

CAUTION 

TO AVOID POSSIBLE DAMAGE TO EQUIPMENT, 

TAKE CARE TO MATCH THE POLARITY SETTING 

ON THE DEMUX24 TO THAT REQUIRED BY 

CONNECTED EQUIPMENT. 

 