background image

 
 
 
 
 
 
 

Содержание GR250BC

Страница 1: ...INSTRUCTIONS ZERO MODEL GR250BC L P Gas Double Lid Bottle Cooler ZERO APPLIANCES PTY LTD Cat I3 28 30 37 I3B P 30 WARNING THIS APPLIANCE MUST BE EARTHED ENSURE THAT THE GAS SUPPLY HOSE IS NOT IN CONTA...

Страница 2: ...pane mixtures at 3 0 kPa Declared Rate Injector size 0 42mm diameter marked 13 or 0 Gas consumption 34 2 g h Electrical Supply optional 230V 0 320kW WARNING THIS APPLIANCE MUST BE EARTHED ENSURE THAT...

Страница 3: ...be installed in accordance with the requirements of SANS 10087 1 and any fire department regulations and or local bylaws applicable to the area If in doubt check with the relevant authority before und...

Страница 4: ...n 15 seconds see Users note BURN BACK FIRE IN BURNER TUBE OR CHAMBER In the event of a burn back where the flame burns back to the jet immediately turn off the gas supply at the control valve on the p...

Страница 5: ...e Press A again 5 Keep the knob A pressed in for a further 15 seconds then release it If the flame goes out repeat steps 2 3 and 4 until the flame stays alight To terminate the gas operation turn off...

Страница 6: ...l is defective 7 The baffle has not been inserted into the chimney factory fitted 8 The absorption unit is leaking A leak can be determined in the case of a visible leak by traces of yellow deposit at...

Страница 7: ...hich the lid is opened and the volume and concentration of products stored in it 10 You avoid packing products in too tightly air must be able to circulate freely 11 For the safety of children keep th...

Страница 8: ...w used for admitting the ammonia hydrogen filling charge to an absorption unit is fitted to the unit s reservoir It is a strictly applied provision of the guarantee extended on the unit to the custome...

Страница 9: ...burner will not stay alight check position of the flame detector head and the functioning of the safety valve If not cold enough Check through points listed under Troubleshooting In the unlikely event...

Страница 10: ...SUPPLY HOSE IS NOT IN CONTACT WITH OR NEAR THE BURNER BOX 1 SANS BRASS HOSE TAIL 2 GAS THERMOSTAT 3 CAPILLARY WIRE 4 FLAME FAILURE DEVICE 5 M10 NUTS 6 M10 x 3 8 UNF JET HOLDER 7 M10 x 1 JET RETAINER...

Страница 11: ...Made in South Africa Pty Ltd...

Страница 12: ......

Отзывы: