background image

PG5

ZCOMV2 |CONTROL PANEL | COMANDO 24V

DIP 1 - ON

 and 

DIP 2  - OFF

Condominium function with automatic closing:

Transmitters aren’t accepted during opening and during clo

-

sing  it  reverses  direction  and  stops  only  at  the  gate’s  end. 

Transmitters are not accepted during the pause time.

DIP 1 - OFF

 and 

DIP 2  - OFF

Normal Step-by-step function with automatic closure.

Gate opens or closes only if it receives transmitter signals.

The behavior will be open-stop-close-stop-open.

DIP 3  - ON

Programing  pause  time  before  automatic  closing  to  60  se

-

conds

DIP 3 - OFF

Programing  pause  time  before  automatic  closing  to  15  se

-

conds

DIP 4  - ON 

Enables the SOFT STOP function. 

The SOFT STOP function is triggered 3 seconds after the con

-

trol board receives the limit-switch signal. When it receives, it 

immediately starts soft automation  stopping.

DIP 4 - OFF

Disables the SOFT STOP function and stops the gate immedia

-

tely on limit-switch position.

DIP 5 - ON 

Enables  blink  function  2  seconds  before  opening  commen

-

ces.. 

DIP 5  - OFF

Disables blink function 2 seconds before start opening com

-

mences. 

DIP 6  - ON

Enables  more  force/torque  during  the  opening  operation.  

The  motor  force  will  be  double  and  sensitivity  less  during 

opening of that set by TR11 and during closing will be as per 

the setting of TR11.

NOTE:  USED ONLY FOR OVERHEAD GARAGE DOORS APPLI-

CATION

DIP 6 - OFF

Enables  anti-crushing  function  during  opening  and  closing,  

has the same obstacole sensitive function.

DIP 7 - ON

Enables automatic closing 3 seconds after photocells  are in

-

terrupted

DIP 7 - OFF

Disables automatic closing 3 seconds after photocells  are in

-

terrupted.

DIP 8  - ON

Disables the M2/11 safety device (PHOTOCELLS) reading.

DIP 8 - OFF

Enables the M2/11 safety device (PHOTOCELLS) reading.

NOTE: The DIP SWITCH 8 puts a link across the safety device 

and common, instead of using a link wire.

DIP 9  - ON

Disables the M2/12 safety device (STOP BUTTON) reading.

DIP 9 - OFF

Enables the M2/12 safety device (STOP BUTTON) reading.

NOTE: The DIP SWITCH 9 puts a link across the safety device 

and common, instead of using a link wire.

DIP 10  - ON

Disables the M2/13 safety EDGE device reading.

DIP 10 - OFF

Enables the M2/13 safety EDGE device reading.

NOTE: The DIP SWITCH 10 puts a link across the safety device 

and common, instead of using a link wire.

Содержание COMANDO 24

Страница 1: ...PG1 ZCOMV2 CONTROL PANEL COMANDO 24V USER MANUAL AND CONFIGURATION ZCOM24 VER1 0 01012018_REV1 IT EN FR COMANDO 24 CONTROL UNIT SLIDING GATES AND GARAGE DOORS 24V made in italy ...

Страница 2: ...PG2 ZCOMV24 CONTROL PANEL COMANDO 24V ...

Страница 3: ...mains power supply The installer must inform the client how to handle the product in case of emergency and provide this manual to the user Keep remote controls away from children to prevent the au tomated system from being activated involuntarily The customer shall not under any circumstances attempt to repair or tune the automation and must call a qualified techni cian only Connect the automation...

Страница 4: ...losing swap the wires from 14 and 15 terminals Close the gate and re lock the motor 04 When the gate arrives at the closed position press the SW1 PROGRAM button located on the control board for 2 se conds until the CODE LED see connection diagram page stays illuminated immediately press the transmitter button you want to be the total opening key NOTE When the transmitter button is pressed the CODE...

Страница 5: ...ds before start opening com mences DIP 6 ON Enables more force torque during the opening operation The motor force will be double and sensitivity less during opening of that set by TR11 and during closing will be as per the setting of TR11 NOTE USED ONLY FOR OVERHEAD GARAGE DOORS APPLI CATION DIP 6 OFF Enables anti crushing function during opening and closing has the same obstacole sensitive funct...

Страница 6: ...cept wire safety edges USE DIP 10 to set function ON BOARD MAGNETIC LIMIT SWITCH FUNCTION the control unit is equipped with a CN2 connector to accommodate a ma gnetic limit switch module directly welded on control panel on demand and just for Z01 model BATTERY EMERGENCY FUNCTION BLACK START The control board is equipped to operate in emergency with a single 12v battery and with a battery rechargin...

Страница 7: ...PG7 ZCOMV2 CONTROL PANEL COMANDO 24V CONNECTIONS ...

Страница 8: ... CLOSURE for other configuration see the DIP SWICH paragraph OFF DIP 2 ON OFF DIP 3 ON GATE PAUSE BEFORE CLOSING 60 SECOND OFF GATE PAUSE BEFORE CLOSING 15 SECOND DIP 4 ON SOFT STOP ENABLED OFF SOFT STOP DISABLED DIP 5 ON BLINK 2 SECONDOS BEFORE OPENING ENABLED OFF BLINK 2 SECONDOS BEFORE OPENING DISABLED DIP 6 ON ANTI CRUSHING FUNCTION DIFFERENT SENSIVITY WHILE OPENING AND CLOSING GARAGE DOORS OF...

Страница 9: ...PG9 ZCOMV2 CONTROL PANEL COMANDO 24V FOTO FOTO 180 PHOTOCELLS CONNECTIONS ...

Страница 10: ...PG10 ZCOMV24 CONTROL PANEL COMANDO 24V FOTO IN FOTO BATTERY ...

Страница 11: ...EN CLOSE POSITION CONNECTION NOTE ON BOARD MAGNETIC LIMIT SWITCH FUNCTION the control unit is equipped with a CN2 connector to accommodate a magnetic limit switch module directly welded on control panel on demand and just for Z01 model will be also provided two magnetic stoppers for end limit switch positions ...

Страница 12: ...d posi tion Lock motor again and turn off power supply for 5 seconds Reconnect it and send start si gnal using transmitter Gate opened but didn t close again Check if there is any obstacle in front of the photocells Check if any of the control devices key selector push button video intercom etc of the gate are jammed and sending permanent signal to control unit Consult a qualified ZERO tech nician ...

Страница 13: ...ere is some security system malfunction photocells safety edges etc 1 Close with a link wire all safety systems on the control board check manual of the control board in question If the automated system starts working normally check for the problematic device 2 Remove one link wire at a time until you find the malfunction device 3 Replace it for a functional device and check if the motor works cor...

Страница 14: ...CE Directive and that all the rules and or technical specifications shown below have been applied EN 60335 1 EN 60204 1 EN 55014 EN 6100 3 2 EN 6100 3 3 EN 6100 4 2 EN 6100 4 4 ENV50140 EN50081 1 EN50082 1 ALTAVILLA VICENTINA VI Italia 01 07 2016 and he also declares that it is not allowed to commission the device until the machinery where it will be incorporated or who se it will become a compone...

Страница 15: ...PG15 ZCOMV2 CONTROL PANEL COMANDO 24V ...

Страница 16: ...PG16 ZCOMV24 CONTROL PANEL COMANDO 24V ZERO SRLS Via Olona 110 Gallarate VA ITALIA info miozero it www miozero it ...

Отзывы: