PG5
ZCOMV2 |CONTROL PANEL | COMANDO 24V
DIP 1 - ON
and
DIP 2 - OFF
Condominium function with automatic closing:
Transmitters aren’t accepted during opening and during clo
-
sing it reverses direction and stops only at the gate’s end.
Transmitters are not accepted during the pause time.
DIP 1 - OFF
and
DIP 2 - OFF
Normal Step-by-step function with automatic closure.
Gate opens or closes only if it receives transmitter signals.
The behavior will be open-stop-close-stop-open.
DIP 3 - ON
Programing pause time before automatic closing to 60 se
-
conds
DIP 3 - OFF
Programing pause time before automatic closing to 15 se
-
conds
DIP 4 - ON
Enables the SOFT STOP function.
The SOFT STOP function is triggered 3 seconds after the con
-
trol board receives the limit-switch signal. When it receives, it
immediately starts soft automation stopping.
DIP 4 - OFF
Disables the SOFT STOP function and stops the gate immedia
-
tely on limit-switch position.
DIP 5 - ON
Enables blink function 2 seconds before opening commen
-
ces..
DIP 5 - OFF
Disables blink function 2 seconds before start opening com
-
mences.
DIP 6 - ON
Enables more force/torque during the opening operation.
The motor force will be double and sensitivity less during
opening of that set by TR11 and during closing will be as per
the setting of TR11.
NOTE: USED ONLY FOR OVERHEAD GARAGE DOORS APPLI-
CATION
DIP 6 - OFF
Enables anti-crushing function during opening and closing,
has the same obstacole sensitive function.
DIP 7 - ON
Enables automatic closing 3 seconds after photocells are in
-
terrupted
DIP 7 - OFF
Disables automatic closing 3 seconds after photocells are in
-
terrupted.
DIP 8 - ON
Disables the M2/11 safety device (PHOTOCELLS) reading.
DIP 8 - OFF
Enables the M2/11 safety device (PHOTOCELLS) reading.
NOTE: The DIP SWITCH 8 puts a link across the safety device
and common, instead of using a link wire.
DIP 9 - ON
Disables the M2/12 safety device (STOP BUTTON) reading.
DIP 9 - OFF
Enables the M2/12 safety device (STOP BUTTON) reading.
NOTE: The DIP SWITCH 9 puts a link across the safety device
and common, instead of using a link wire.
DIP 10 - ON
Disables the M2/13 safety EDGE device reading.
DIP 10 - OFF
Enables the M2/13 safety EDGE device reading.
NOTE: The DIP SWITCH 10 puts a link across the safety device
and common, instead of using a link wire.
Содержание COMANDO 24
Страница 2: ...PG2 ZCOMV24 CONTROL PANEL COMANDO 24V ...
Страница 7: ...PG7 ZCOMV2 CONTROL PANEL COMANDO 24V CONNECTIONS ...
Страница 9: ...PG9 ZCOMV2 CONTROL PANEL COMANDO 24V FOTO FOTO 180 PHOTOCELLS CONNECTIONS ...
Страница 10: ...PG10 ZCOMV24 CONTROL PANEL COMANDO 24V FOTO IN FOTO BATTERY ...
Страница 15: ...PG15 ZCOMV2 CONTROL PANEL COMANDO 24V ...