Dismantle the cooling unit cover.
Dismantle the base of the burner (
A
): undo the screw and pull down the base of the burner.
Remove the safety plate (
B
).
Pull the burner (
C
) forwards out of the burner.
Unscrew the union nut (
F
).
Unscrew the lock nut (
G
) and take out the burner jet (
H
).
Clean the burner jet (
H
) and burner tube (
C
) with a soft brush. Remove dust particles.
The jet has a very small opening, which may be washed out using benzene only. After washing out,
blow it extensively. Hold the jet against the light to make sure it is clean. Under no circumstance
should hard objects, such as wire or needles, be used for cleaning.
To install, proceed in reverse order. Ensure the burner tube (
C
) is positioned correctly – slot facing
upwards. Then check all screw connections for imperviousness.
Page 14
Dismantle the unit cover.
Unscrew the evaporator cover’s (
A
) two fastening
screws on the inside of the appliance.
Pull the evaporator cover (
A
) up carefully.
The capillary tubes for the electrical and gas
thermostat are under the evaporator cover.
Straighten the capillary tubes carefully and pull
them backwards through the back wall of the
appliance.
NB: the capillary tubes may not be bent with
sharp edges.
Unscrew the evaporator’s (
B
) fastening screw
from the bottom of the container and lift the
evaporator upwards out of the container.
Page 11
C
LEANING / REPLACING THE BURNER JET
R
EPLACING THE COOLING UNIT