EN
16
3
4
5
1
2
9.2 siMPLY sYsTEM
TM
No need to store up on bags or filters thanks to the
siMPLY sYsTEM
TM
.
Cleaning the purification tank is all that is required for top TUTTOLUXO 2S
efficiency. At the end of your work, empty the liquid waste of the purification
tank as shown in (Pict. 3). To make this operation easier, the divider inside the
tank can be taken off (Pict. 4) and it is also advisable to remove the nebulizers
(Pict. 5). Rinse tank, divider and nebulisers with abundant hot water and neutral
detergent until all residues and stains on the tank walls have been removed.
WArNiNG!
We strongly advise, after aspirating liquids or solids, to rinse the water bucket
inside and any accessory used, by emptying the tank and aspirating 1 litre of
cold, clean tap water, repeat this twice. Also, please do not leave any aspirated
liquid inside the tank, to prevent the formation of limescale or moulds, and
consequently bad odours.
WArNiNG!
When you take off the divider, make sure that it is put back correctly into the proper
guides with its curved side facing forwards and upwards and that it touches the
bottom (otherwise it won’t slide in). Please be careful, these are delicate pieces.
In case one gets broken or lost, immediately ask for a spare part from your Zepter
Service Centre. Do not use the TUTTOLUXO 2S without it. Allow all pieces to dry
or dry them yourself before replacing them in the machine and closing the cover.
Moisture left inside could create mildew and unpleasant odours.
rEPLACEMENT oF FiLTErs:
Floater Filter (PWC-700-4):
Replace yearly or earlier according to condition.
Air intake Filter (PWC-700-2):
Replace yearly or earlier according to condition.
Polyester Filter (PWC-700-1):
Replace yearly or earlier according to condition.
Motor intake Filter (PWC-700-3):
Replace yearly or earlier according to condition.
Hepa Filter (PWC-700-5):
Replace every 6-12 months.
To inspect the filter, proceed as for replacing the Polyester Filter
1) Remove the grilled cover on the back of the TUTTOLUXO 2S.
The HEPA filter is fitted inside. Place the grilled cover on the floor and
extract the filter as shown.
2) Check the filter state; if there are traces of dust or dirt, replace it.
3) Put the new HEPA filter into place and reassemble the cover,
making sure to properly fit the grilled cover hooks onto the slits on the
appliance body. Once the grilled cover is in place, rotate it upwards for the
final fixing with the stopping tongue.
After some periods of use, should the HEPA filter be torn or damaged, it should
be replaced with a new one from a Zepter Service Centre.
TANK LiD WiTH FLoAT
Also check efficacy of the Safety Float located on the tank lid. If encrusted
with dirt or mould, this may not function correctly. Check that the float can
move freely within its cage. Rinse the lid with plenty of hot water and neutral
detergent.