background image

A. Please study the user guidance of hydrogen peroxide and do not immerse in solution for a long

time.

B. Do not use strong oxidizing agents such as perchlorate or disinfectants that are corrosive to metals,

polymer compounds or polymers.

2) Ethanol disinfection

Place the liquid cup components (including spray nozzle, medication cover), mask and mouthpiece

in 75% medical ethanol for 5~10 minutes for disinfection, or wipe and disinfect the medication cup

component (including spray nozzle, medication cover), mask and mouthpiece. After disinfection,

rinse all the parts with distilled water, then wipe with clean and sterile medical gauze or air-dry

naturally to keep all parts dry.

Notes: Disinfectants remaining on components need to be wiped with sterile medical gauze to

ensure safe use next time. Do not touch the central area of the mesh diaphragm when washing

or cleaning the spray nozzle, so as to avoid damaging the mesh diaphragm.

5. Technical Data

Product name

Type of battery

Product Item code

Charging time
Usage time
Charger/Adaptor input
Charger/Adaptor output
Country of origin

Portable Mesh Nebulizer
NEB-01-C
Li-ion battery, DC2.4V, 2x500mAh, 1.2 Wh

Approx. 2 hrs

60 minutes continual use after full charge

100-240V~, 50/60Hz, 0.5 A

5V 1.5 A
China

11

Содержание NEB-01-C

Страница 1: ...Instruction for Use Portable Mesh Nebulizer NEB 01 C...

Страница 2: ...Instruction for Use 5 Cleaning and Disinfection Method 6 Technical Data 7 Trouble Shooting Guideline 8 Declaration of Conformity 9 Warranty 4 1 Before First Use 4 2 Installation 4 3 Charging 4 4 Inst...

Страница 3: ...d by persons with reduced physical sensory or mental capabilities or by persons with little or no knowledge of the appliance as long as they are under proper supervision and have received instructions...

Страница 4: ...ck or malfunction Do not touch the center of spray mesh by hand or other sharp objects It may cause damage so you will not be able to use it The nebulizer has no moisture and dust function and the pro...

Страница 5: ...erous and prohibited For your own safety don t remove the battery from the product and please contact only authorized Zepter Service Centre 5 3 Item Description 3 1 Content of Packaging 3 2 Device des...

Страница 6: ...apter with rated output DC 5 0 V 1A 3 While the device is charging the green indicator ashes continually 4 The LED indicator is lit steadily when the battery is fully charged 5 The appliance can be us...

Страница 7: ...ight ashes ten times While the orange light is ashing press switch key once to continue work Long press for 3 seconds to switch the atomization mode Blue light keeps on uniform nebulization mode Blue...

Страница 8: ...an t be shared to avoid cross infection 4 5 Nebulization 1 Connect mask or mouthpiece click to switch power on start nebulization 2 It starts with a medium spray rate and spray rate can be adjusted by...

Страница 9: ...l liquid in the medication cup and do not reuse 9 Use clean water to clean the medication cup spray nozzle lid threaded assemblies and accessories and then follow the recommended method of disinfectio...

Страница 10: ...clean it with wet sterile medical gauze After cleaning keep the main unit dry 4 Store all the parts in a dry and clean place to avoid contamination 10 2 Disinfection After each use it is necessary to...

Страница 11: ...r disinfection rinse all the parts with distilled water then wipe with clean and sterile medical gauze or air dry naturally to keep all parts dry Notes Disinfectants remaining on components need to be...

Страница 12: ...4 The spray mesh may be blocked you can drop 2 or 3 drops of white vinegar into the medication cup with 3 6 ml of water Clean the medication cup to disinfect for next nebulization 1 Please refer to a...

Страница 13: ...er cannot be held responsible for any damage deriving from improper incorrect or unreasonable use All our appliances have undergone strict inspection test and are guaranteed against manufacturing defe...