ZT MK2
36
Connection of controller and warning lights
www.zepro.com
6.3
Connection
The connection of warning lights and the most commonly occurring controller (CD (Control Device)) mod-
els is shown below. Possible control device models vary depending on lift model, configuration and the market
concerned.
m
WARNING!
Make sure that the control card is disconnected from the power before connecting. Connecting more
than one controller to each connection is not permitted. Risk of physical damage.
Picture 51. Connection of controller and warning lights
WL1 U7 U6 U5 U5 U4 U4 U3 U2 U1 U0
+
+
WL2
PA+
S5
S1+
S4
S3
S2
S1
S5+
S4+
S3+
S2+
PA-
CS
CS+
Down
2H
Out
Down
Down
C1+
C1+
Up
Tilt
In
C2+
Up
Tilt
C3+
Up
Ctrl 3
Ctrl 2
Ctrl 1
CD3
CD10
CD14
+
U1
U2
U3
U0
+
CD11
CD18*
CD9
CD19
Black
C1+
White
( ), if available)
Brown
Up
Yellow
Down
Blue
Tilt
Green
In
Grey
Out
Black
C3+
White
( ), if available)
Brown
Up
Yellow
Down
Black
C3+
Brown
Up
Yellow
Down
Warning lights
Blue
WL1
Black (+)
White (-)
Brown
Up
Yellow
Down
Blue
Tilt
Grey
Not used
* In some cases there may
also be a blue cable on the
CD18. It must NOT be con-
nected in this case.
Black
C2+
White
( ), if available)
Brown
Up
Yellow
Down
Blue
Tilt