background image

Mounting the Range Hood

1.  Mark hood center on Center hood on wall.

2. Mark and Install Wall Mount Bracket to 

Wall.  (For hollow drywall, use E-Z 
Anchors, please see next page)

3. Fasten hood onto Wall Mount Bracket 

with screws provided.

INSTALLATION

INSTALLATION

33-7/8"

31-7/8"

27-7/8"

Wall Mount Bracket

Wall Mount Bracket

EZ ANCHORS (See next page)

5

Содержание ZTO-M79S

Страница 1: ...en the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust cigarette ashes hazardous or explosive materials and vapors WARNING TO REDUCE THE RISK OF RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spil...

Страница 2: ... damage electrical wiring and other hidden utilities d Ducted fans must always vent to the outdoors WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK CAUTION To reduce risk of fire and to proerly exhaust air outside Do not vent exhaust air into soaces within walls ceilings attics crawl spaces or garages WARNING TO REDUCE THE RISK OF SHOCK THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL ...

Страница 3: ...ing the hood EZ Anchors Ductless Conversion Carbon Filters 1 1 2 3 4 4 5 6 6 7 7 8 8 8 9 8 10 11 12 13 FEATURES CONTROLS Touch controls features Advance display functions Filter change indicator Filter clean indicator MAINTENANCE Cleaning Lights replacement WARRANTY Coverage exceptions ...

Страница 4: ...2ECTANGULAR X MINIMUM REQUIRES A TO X ADAPTOR NOT SUPPLIED UCT 2UN ALCULATION AXIMUM RUN OR X DUCT 4 4 4 4 4 4 4 EDUCT EACH LBOW USED EACH ELBOW USED EACH TO X TRANSITION USED EACH X TO TRANSITION USED 3IDE 7ALL AP W DAMPER 2OOF AP E G ROOF CAP X ELBOWS ELBOW USED g g g g USED g AVAILABLE FOR STRAIGHT DUCT RUNS INIMUM MOUNT HEIGHT BETWEEN RANGE TOP TO HOOD BOTTOM SHOULD BE NO LESS THAN AXIMUM MOUN...

Страница 5: ...utside Use Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options WARNING FIRE HAZARD side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap side wall cap w gravity damper Soffit 6 to 3 1 4 x 10 elbow adaptor Air register Ductless Re circulating option ...

Страница 6: ...INSTALLATION DUCTING 6 to 3 1 4 x 10 elbow adaptor Air Diverting Kit Air register Ductless Re circulating option Ductless Re circulating option Crawl space 3 ...

Страница 7: ...local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A cable locking connector not supplied might also required by local codes...

Страница 8: ...Mark and Install Wall Mount Bracket to Wall For hollow drywall use E Z Anchors please see next page 3 Fasten hood onto Wall Mount Bracket with screws provided INSTALLATION INSTALLATION 33 7 8 31 7 8 27 7 8 Wall Mount Bracket Wall Mount Bracket EZ ANCHORS See next page 5 ...

Страница 9: ...te Whenever possible the hood should be secured to wall studs Use EZ anchors provided only on hollow drywall applications minimum drywall thickness If a stud or wood surface is present fasten anchors with screws directly into stud or plywood For all other wall types concrete brick tiles etc use appropriate anchors for mounting 6 ...

Страница 10: ... INSTALLED 7HEN CONVERTED THE HOOD FUNCTIONS AS A PURIFYING HOOD RATHER THAN AN EXHAUST HOOD UMES AND EXHAUST FROM COOKING IS DRAWN AND FILTERED BY A SET OF OPTIONAL ARBON ILTERS 4HE AIR IS THEN PURIFIED AND RE CIRCULATED BACK WITHIN THE HOME 7E RECOMMEND TO 7 93 EXHAUST AIR OUTSIDE OF THE HOME BY EMPLOYING EXISTING OR INSTALLING NEW DUCT WORK IF POSSIBLE 4HE HOOD IS MOST EFFECTIVE AND EFFICIENT A...

Страница 11: ...itted are required to be cleaned frequently and as recommended in order to maintain blower efficiency If improperly maintained residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components and possibly clog duct work and creates fire hazard Filters Change Reminder Carbon if fitted When your hood is installed as a Purifying Ductless Recirculating uni...

Страница 12: ...n carbon filter replacement is needed every 120 hrs Setting the Filter Change Reminder When Off hold for approx 5 seconds The display will change from exhaust mode to purifying mode carbon filters used this indicates that the elapse timer function is switched on and Carbon Filters are used Filter Replace Indicator When the display starts flashing the Carbon Filters requires replacement after 120 h...

Страница 13: ...rs of use Filters can be cleaned by hand or in a dishwasher with non abrasive soap Heavily soiled filters should also be soaked in grease cutting detergent such as 409 or its equivalent prior to cleaning Filter Clean Reminder When flashes on display the metal filters installed are required to be cleaned This will occur after every 30 hours of use Re setting Function Reset the Filter Clean Reminder...

Страница 14: ... 4HE ETAL ILTERS FITTED BY THE FACTORY ARE INTENDED TO FILTER OUT RESIDUE AND GREASE FROM COOKING T NEED NOT BE REPLACED ON A REGULAR BASIS BUT ARE REQUIRED TO BE KEPT CLEAN ILTERS SHOULD BE CLEANED AFTER EVERY HOURS OF USE 5SE THE ILTER LEAN 2EMINDER FUNCTION ON THE CONTROLS TO DETERMINE WHEN FILTERS REQUIRE CLEANING REF PAGE 2EMOVE AND CLEAN BY HAND OR IN DISHWASHER 3PRAY g ORMULA g OR EQUIVALEN...

Страница 15: ...not hot Carefully pry trim w glass off the socket module Replacement bulb w 12V 20W type bulbs Replacing Light Bulbs CAUTION Light bulb becomes extremely hot when turned on DO NOT touch bulb until switched off and cooled Touching hot bulbs could cause serious burns 12 ...

Страница 16: ...e you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING S...

Страница 17: ...5 2 7 22 49 OR ANY 3ERVICE 2ELATED 1UESTIONS PLEASE CALL AVE YOUR PRODUCT PROOF OF PURCHASE WITH DATE READY FOR WARRANTY ISSUES R WRITE TO EPHYR ORPORATION 3ERVICE AND 7ARRANTY DEPARTMENT ENDELL 3T 3AN RANCISCO ...

Отзывы: