Maintenance – 

Cleaning and Installing Filters

SURFACE MAINTENANCE:

clean periodically with hot soapy water and clean cotton cloth. do not use corrosive or abrasive detergent, 

or steel wool/ scoring pads which will scratch and damage surface.  do not use products containing chlorine 

bleach or orange cleaners.

for heavier soil use liquid degreaser.

After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless 

luster and grain. Always scrub lightly using a micro fiber or clean cotton cloth and with the grain.

Baffle Filters

The filters are intended to trap residue and grease from cooking. Although the filters should never need 

replacing, they are required to be cleaned every 30 days or more often depending on cooking habits.

Filters may be placed in dishwasher at low heat or soaked in hot soapy water  Dry filters and re-install before 

using hood.

Installing Baffle Filters (FIG 4):

1.   Place filter into top groove of the power pack as shown and 

      pull towards front of power pack using handles.

2.   Pivot back of filter upwards so it is angled in the power pack.
3.   Push filter into channel on back of power pack to lock into place.

Replacing/Ordering Baffle Filters:

Hood Model: 

Part No.  

Qty. to Order  

AK8800Ax 

50210010 

        2

1

2

FIG 4

3

CAUTION: If this hood is installed in a salt water area (example: coast),

rinse all surfaces once a week with clear water (even if the hood is not used), and wipe dry completely.

!

Содержание Willow AK8800AS

Страница 1: ... Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer APR14 0201 2014 Zephyr Corporation Willow AK8800AS AK8800AG READ AND SAVE THESE INSTRUCTIONS Intended for outdoor covered patio or lanai area ...

Страница 2: ...www zephyronline com ...

Страница 3: ...Sheet 5 Mounting Height Clearance 6 Ducting Options 7 Specifications 8 Electrical 9 Installing the Power Pack 10 CONTROLS Rocker Switch Controls 11 MAINTENANCE Cleaning and Installing Filters 12 Lights 13 TROUBLESHOOTING 14 LIST OF PARTS AND ACCESSORIES 15 Table of Contents ...

Страница 4: ...unattended when cooking h Always use cookware and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND C...

Страница 5: ...ark Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Diagram on product AK8800Ax 710W 6 Amps A ca...

Страница 6: ...Power Pack AK8800AG 2 Baffle filters 2 Halogen light bulbs pre installed 1 Dual internal blower pre installed 1 8 round adapter 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Optional stainless steel hood liner AK08xxAS Suction Cup 1 M4 x 8 4 Wire Caps 3 M4 x 1 6 ...

Страница 7: ... Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15 Ft x Ft 7 10 7 10 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 Round roof cap 30 Ft x Ft 7 10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork 6 roundto 3 1 4 x 10 rect transitio...

Страница 8: ...tions are required install as far away from hood duct output and as far apart between the two as possible Minimum mount height between range top to hood bottom should be no less than 30 Maximum mount height should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will...

Страница 9: ...ll exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ...

Страница 10: ...s top side front CL 11 7 16 13 16 2 5 8 14 11 16 15 13 16 2 3 8 14 3 4 24 5 8 25 15 16 29 13 16 1 5 16 1 1 2 CL elec k o 5 7 3 4 4 3 8 1 1 2 1 3 4 elec k o 6 1 2 15 13 16 14 11 16 11 7 16 11 7 16 4 3 4 316 High Class Stainless Steel Body for AK8800AS ...

Страница 11: ...Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A cable locking connector not supplied might also be required by local codes Check with local requir...

Страница 12: ...ood blocking may need to be added to cabinet base if additional support is needed 6 Install 8 round duct work and seal with duct tape Depending on the contruction of the custom hood the duct work may need to be installed on top of the Power Pack prior to mounting the Power Pack inside your custom hood 7 Install electrical 8 Remove all packing materials before using Power Pack Switch power on and c...

Страница 13: ... is on is off Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two Lights On Off Adjust Blower Level 2 Speeds 1 1 2 2 Switching the rocker switch to middle will turn off the blower Controls Rocker Switch Controls ...

Страница 14: ...e and grease from cooking Although the filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry filters and re install before using hood Installing Baffle Filters FIG 4 1 Place filter into top groove of the power pack as shown and pull towards front of ...

Страница 15: ...ve by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type MR16 GU 10 35W halogen For Zephyr part nu...

Страница 16: ...od is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb is loose 2 Tighten the light bulb 3 The wires on the control board are loose 3 Make sure the wires on control board are connected properly The hood is not venting out properly 1 The hood might be hanging too high from the co...

Страница 17: ... Light Bulb MR16 GU10 35W each Z0B 0023 Baffle Filter each 50210010 Optional Accessories Liner 36 AK0886AS Liner 42 AK0882AS Liner 48 AK0888AS Liner 54 AK0884AS Liner 60 AK0880AS To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 ...

Страница 18: ...irst year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PR...

Отзывы: