TROUBLESHOOTING PROCEDURES FOR VENEZIA WALL

Issue

Cause

What to do

After installation, 
the unit doesn’t 
work.

1.  The power source is not turned ON.

1.  Make sure the circuit breaker and the unit’s 

power is ON.

2.  The power line and the cable locking connector 

is not connecting properly.

2.  Check the power connection with the unit is 

connected properly.

3.   The wires on the control board are loose.

3.   Make sure the wires on the control board are 

connected properly.

4.  The switch board and control board wirings are 

disconnected.

4.  Make sure the wirings between the switch 

board and control board are connected 
properly.

5.  The switch board or control board is defective.

5.  Change the switch board or control board.

Light works, but 
blower is not 
turning.

1.   The blower cable is disconnected.

1.   Check all wirings from the blower to be sure 

all cables are connected properly.

2.  The blower is defective, possibly seized.

2.  Change the blower.

3.  The thermally protected system detects if the 

blower is too hot to operate and shuts the blower 
down.

3.  The blower will function properly after the 

thermally protected system cool down.

4.  The switch board or control board is defective.

4.  Change defective part.

The LCD screen 
is blinking.

1.   The cable between the switch board and control 

board is disconnected.

1.   Check the cable connection between the 

switch board and control board.

The unit is 
vibrating.

1.  The motor is not secure in place.

1.  Tighten the motor in place.

2.  Damaged blower wheel.

2.  Replace the blower.

3.  The hood is not secured in place.

3.  Check the installation of the hood.

The unit is 
whistling.

7KH¿OWHULVQRWLQWKHFRUUHFWSRVLWLRQ

$GMXVWWKH¿OWHUVXQWLOWKHZKLVWOLQJVWRSV

2.   The duct pipe connections are not sealed or 

connected properly.

2.   Check the duct pipe connections to be sure all 

connections are sealed properly.

The blower is 
working, but the 
lights are not.

1.  Defective LED bulb.

1.  Change the LED bulb.

2.  The LED bulb wire is loose.

2.  Check LED wire connections at the control 

board and the LED light bulbs. Reconnect any 
loose wires.

The speed levels 
of the blower 
sound the same.

1.   Using the wrong size of ducting. 

1.   Change the ducting to at least 8” or higher.

2.   ACT enabled blower CFM set to 290 or 390 

CFM.

2.   Noise level distinction between some speeds 

may be minimal when ACT enabled blower is 
set to 290 or 390 CFM.

The hood is 
not venting out 
properly.

1.  The hood might be hanging too high from the 

cook top.

1.  Adjust the distance between the cook top and 

the bottom of the hood within 26” and 34” 
range.

2.  The wind from the opened windows or opened 

doors in the surrounding area are affecting the 
ventilation of the hood.

2.  Close all the windows and doors to eliminate 

WKHRXWVLGHZLQGÀRZ

3.  Blockage in the duct opening or ductwork.

3.  Remove all the blocking from the duct work or 

duct opening.

4.  The direction of duct opening is against the wind.

4.  Adjust the duct opening direction.

5.  Using the wrong size of ducting.

5.  Change the ducting to at least 8” or higher for 

the internal blower.

Содержание Venezia ZVE-E30BS

Страница 1: ...allation Guide www zephyronline com Model number Serial Number APR14 0601 Zephyr Corporation For use with models of serial numbers beginning with 21 Air ow Control Technology TM C Venezia ZVE E30BS ZV...

Страница 2: ...www zephyronline com...

Страница 3: ...nce 6 Ducting Options 7 RRG 6SHFL FDWLRQV 8 Mounting the Range Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Touch Controls 11 User Interface 12 MAINTENANCE Cleaning and Filter Care 13 TROUBLESHO...

Страница 4: ...are and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK...

Страница 5: ...rds C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances I FRGHV SHUPLW DQG D VHSDUDWH JURXQG ZLUH LV XVHG LW LV UHFRPPHQGHG WKDW D TXDOL HG HO...

Страница 6: ...cover extension accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS MODELS ZVE E30BS ZVE E36BS ZVE E42BS PARTS SUPPLIED 1 Hood with internal blower 3 Aluminum mesh filters 2 for ZVE E30BS...

Страница 7: ...1 Duct pieces T otal Equivalent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 F...

Страница 8: ...DQG HI FLHQF If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover...

Страница 9: ...de unless using the recirculating option Use single wall rigid Metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Opt...

Страница 10: ...FL FDWLRQV Top of Hood Side of Hood Front of Hood 7 15 16 4 9 16 5 3 16 5 1 4 AC In C L 5 8 14 5 16 29 15 16 35 7 8 6 7 16 10 1 4 STANDARD min ducted 27 min recirc 31 1 2 max 44 Z1C 01VE min ducted 45...

Страница 11: ...ood Reposition electronics mounting bracket to hood and VHFXUH E WZR SUH LQVWDOOHG VFUHZV DV VKRZQ LQ 9 Install electrical 10 Install duct work and duct tape 11 Power up hood and check for leaks aroun...

Страница 12: ...SXULI IXPHV H KDXVWHG from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED LW LQFOXGHV FKDUFRDO OWHUV DQG DLU GLYHUWHU SODWH Hood Model Part No Filters in Pkg ZVE E30BS ZR...

Страница 13: ...CFM to align with local codes and regulations To verify the maximum blower CFM With hood off hold the Button for three seconds The blower CFM will be displayed on the LCD 2 Speed Selection Button Fan...

Страница 14: ...ing it is time to replace the charcoal filter Graphic and words will remain illuminated until reset To reset With hood off hold the Button for three seconds after three seconds the Graphic and words r...

Страница 15: ...UHVLGXH DQG JUHDVH IURP cooking They need not be replaced on a regular basis but are required to be kept clean IWHU KRXUV RI XVH WKH ZRUGV FOHDQ PHVK OWHU ZLOO LOOXPLQDWH RQ WKH FRQWURO VFUHHQ LQGLFDW...

Страница 16: ...ating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood The unit is wh...

Страница 17: ...set the maximum blower speed to RQH RI WKUHH PRVW FRPPRQO VSHFL HG 0 OHYHOV RU 0 7KH XVDJH RI 7 PD QRW EH necessary for your installation Please check your local codes for CFM restrictions By default...

Страница 18: ...16 www zephyronline com Fan Curve Diagrams...

Страница 19: ...gram 4 A 4 A 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW 0 EORZHU FRQ JXUDWLRQ ACT 590 CFM Fan Max 130W 1 8A ACT 390 CFM Fan Max 70W 1A ACT 290 CFM Fan Max 35W 55A 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW 0 EORZHU...

Страница 20: ...HDFK Optional Accessories Recirculating Kit ZVE E30BS ZRC 00VE Recirculating Kit ZVE E36BS E42BS ZRC 01VE 5HSODFHPHQW KDUFRDO LOWHU HDFK Duct Cover Extension Kit Z1C 01VE To order parts visit us onlin...

Страница 21: ...rst year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SH...

Страница 22: ...de mod le _________________ Num ro de s rie _________________ APR14 0601 Zephyr Corporation Pour une utilisation avec des mod les de num ros de s rie commen ant par 21 Air ow Control Technology TM C V...

Страница 23: ...www zephyronline com...

Страница 24: ...tallation pour le conduit 7 6SpFL FDWLRQV GH OD KRWWH 8 Montage de la hotte 9 Reprise d air sans conduit 10 COMMANDES RPPDQGHV j HI HXUHPHQW 11 Interface utilisateur 12 ENTRETIEN 1HWWR DJH HW HQWUHWLH...

Страница 25: ...pas la hotte sans surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R...

Страница 26: ...dition du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien de l lectricit section 1 la plus r cente dition du code C22 2 No 0 M91 ainsi que tous les codes et r glements en vigueur 6L OHV F...

Страница 27: ...pour recouvrement de conduit Accessoire ensemble de reprise d air CONTENU DE LA TROUSSE DE QUINCAILLERIE MOD LES ZVE E30BS ZVE E36BS ZVE E42BS PI CES FOURNIES 1 Hotte avec ventilateur interne 3 Filtr...

Страница 28: ...gth x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x...

Страница 29: ...les consultez les exigences de hauteur d espace libre requise par le fabricant de la cuisini re ainsi que la hauteur recommand e de montage de la hotte au dessus de la surface de cuisson Informez vous...

Страница 30: ...z que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban adh sif en toile ou GX UXEDQ Up HFWHXU FHUWL p Quelques opt...

Страница 31: ...hotte C t de la hotte Devant de la hotte 7 15 16 4 9 16 5 3 16 5 1 4 Entr e CA L C 5 8 14 5 16 29 15 16 35 7 8 6 7 16 10 1 4 STANDARD Min avec conduit 27 Min avec reprise d air 31 1 2 max 44 Z1C 01VE...

Страница 32: ...ort de montage du dispositif lectronique la KRWWH HW H OH j OD KRWWH j O DLGH GHV GHX YLV SUpLQVWDOOpHV FRPPH VXU OD 1 9 Proc dez l installation lectrique 10 Installez les conduits et le ruban conduit...

Страница 33: ...ENSEMBLE DE REPRISE D AIR REQUIS SI AUCUN CONDUIT N EST UTILIS HQVHPEOH FRPSUHQG GHV OWUHV j FKDUERQ HW XQ Gp HFWHXU G DLU Mod le de hotte Num ro de pi ce Filtres par paquet ZVE E30BS ZRC 00VE 2 ZVE E...

Страница 34: ...contr ler le maximum CFM de la ventilateur Pour v rifier le CFM du vos ventilateur Avec la hotte d sactiv maintenez le bouton pendant trois secondes Le CFM de la ventilateur sera affich sur l cran LCD...

Страница 35: ...usqu la r initialisation de la fonction Pour r initialiser Lorsque la hotte est teinte appuyez et tenez la touche enfonc e pendant trois secondes Apr s trois secondes le symbole et les mots replace ch...

Страница 36: ...aucun remplacement sur une base r guli re mais doivent tre gard s propres SUqV KHXUHV G XWLOLVDWLRQ OHV PRWV FOHDQ PHVK OWHU V LOOXPLQHQW VXU OH WDEOHDX GH FRPPDQGH LQGLTXDQW TX LO HVW WHPSV GH QHWWR...

Страница 37: ...pH HQ SODFH 9pUL H O LQVWDOODWLRQ GH OD KRWWH 4 Tableau de contr le commande d fectueux 4 Remplacez la pi ce d fectueuse Les niveaux de vitesse de OD VRXI HULH OH m me son 1 Utilisation de la mauvais...

Страница 38: ...entilateur l un des trois les plus couramment prescrits niveaux de CFM RX 0 XWLOLVDWLRQ GH O 7 SHXW rWUH SDV QpFHVVDLUH SRXU YRWUH LQVWDOODWLRQ 6 LO YRXV SODvW YpUL H YRV FRGHV ORFDX SRXU FRQQDvWUH OH...

Страница 39: ...16 www zephyronline com Courbe de rendement du ventilateur 390 CFM Entree en CA 120V 60 Hz Diametre du conduit de sortie 8 Pression en TQ Debit pi3 min Tableau De Rendement Du Ventilateur...

Страница 40: ...CHEMENT DESCOMMANDES DEL DEL DEL DEL CCIDESCOMMANDES HAUT BAS DEL SCH MADECIRCUITS BO TIER MOTEUR CC BLANC NOIR VERT LAMPE BRANCHEMENT DESCOMMANDES DEL DEL DEL CCIDESCOMMANDES HAUT BAS DEL 4 A 4 A RQV...

Страница 41: ...ue Z0B 0032 Accessoires optionnels Ensemble de reprise d air ZVE E30BS ZRC 00VE Ensemble de reprise d air ZVE E36BS E42BS ZRC 01VE Filtres charbon de remplacement chaque Z0F C002 Ensemble de prolongem...

Страница 42: ...responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE R...

Отзывы: