DUCTING

9"

36"

Min 98"-Max 124”

Min 28"-Max 36"

Min 34"-Max 52"

Minimum mount height between range top to hood bot-

tom should be no less than 28".

Maximum mount height should be no higher than 36".

It is important to install the hood at the proper mounting

height. Hoods mounted too low could result in heat

damage and fire hazard; while hoods mounted too high

will be hard to reach and will loose its performance and

efficiency.

If available, also refer to range manufacturer's height 

clearance requirements and recommended hood 

mounting height above range. Always check your local

codes for any differences.

A minimum of 6” round or 3-1 /4 x 10"

rectangular duct work must be used to maintain

maximum air flow efficiency with the 600  cfm

internal blower. A minimum of 10” to  8” round must 

be used with the 1000  cfm external blower.

Always use rigid type metal duct work only.

Flexible ducts could restrict air flow by up 

to 50%.

Use  calculation worksheet to compute total

duct work.

ALWAYS, when possible, reduce the number 

or transitions and turns. If a reducer is used,

install a long reducer instead of a pancake

reducer. Reduce duct size as far away from

opening as possible.

If turns or transitions are required:

Install as far away from opening and as far

apart, between 2, as possible.

Minimum

  Duct

  Size:

Round - 6” minimum at 600  cfm

Round - 10” to  8” minimum  at 1000  cfm

Rect angular - 3 1/4”  x 10”  minimum only if

using internal blower at 600  cfm. Using 

rectangular ductwork will require a transition

adapter (not provided, but readily available at

most hardware stores). 

DAMAGE-SHIPMENT /

  INSTALLATION:

• Please  fully inspect unit for damage

befor e

installation.

If the unit is  damaged  in shipment

, return

the unit to the store in which it was bought 

for repair or replacement.

• 

If the unit is  damaged  by the customer

repair or replacement is the responsibility 

of the customer.

• 

If the unit is  damaged  by the ins taller

(if 

other than the customer), repair of replace

ment must be made by arrangement 

between customer and installer.

*Minimum ceiling height of 98”. Hood 

mounted at 28” above cooking surface.

**Maximum ceiling height of 124".  Hood 

mounted at 36"  above cooking surface.

Содержание Trapeze CTP-E 48SX

Страница 1: ...Trapeze CTP E 48SX CTP E54SX CTP E 60SX Model number Serial number Use Care and Installation Guide MAY07 0101 Zephyr Corporation www zephyronline com Date of Purchase Sales Dealer...

Страница 2: ...www zephyronline com...

Страница 3: ...ion Sheet Mounting Height and Clearance Ducting Specifications Internal Blower Preparing Hood for External Blower Mounting the Hood FEATURES CONTROLS Controls Overview MAINTENANCE Cleaning Lights TROU...

Страница 4: ...DO NOT USE WATE R includingwet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate...

Страница 5: ...s 4 Adhesive Fasteners 4 Cable Ties 1 SMALL HARDWARE PACKET 10 Short Set Screws 12 MediumSet Screws 1 Tool 1 1 External Flange with Attached 8 Collar 1 Junction Box with Wires 1 External Blower Wiring...

Страница 6: ...straight 1 Ft x Ft Subtotal column 1 Duct pieces Total Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft 7 Round wall cap with damper 30 Ft x Ft 7 Round 900 elbow 15 Ft x Ft 7 Ro...

Страница 7: ...et to computetotal duct work ALWAYS when possible reduce the number or transitions and turns If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from...

Страница 8: ...attics or garages All exhaust must be ducted to the outside Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duc...

Страница 9: ...9 6 9 2 5 x a M 4 3 n i M 26 5 8 32 48 54 59 1 8 Min 21 Max 40 12 1 8 7 n o i t a l l a t s n I s n o i t a c i f i c e p S 2 2 7 64 13 32 32 9 6 1 7 0 1 2 1 9 9 8 1 4 R 2 3 5 1 8 3 1 4 6 1 2 0 1 O 10...

Страница 10: ...nstructions on preparing for external blower model CBE 1000 please turn to page 10 Before installing verify that motor spins freely 1 Remove existing screws from blower housing 2 Attach capacitor box...

Страница 11: ...as shown 8 Place blower with attached flange into motor housing as shown on Fig A 9 Attach using 1 2 self tapping screws to secure in place 10 Att ach other end of capacitor box connector and junction...

Страница 12: ...ternal blower model CBI 600 please turn to page 8 1 P osition and attach external blower wiring box and junction box using provided 1 2 self tapping screws and 4mm internal diameter washers 2 Attach g...

Страница 13: ...wood blockings minimum 2x4 studs to ceiling joists 4 Center mark and fasten ceiling mounting plate onto ceiling where hood is to be hung Make sure the tabs on the ceiling bracket are positioned to th...

Страница 14: ...ermine height of hood measure and select either 27 3 8 or 35 3 8 angle brac kets and attach 4 of them to the motor housing using 8 1 2 self tapping screws 2 for each angle bracket 3 Slide duct covers...

Страница 15: ...will fit between the slots on the ceiling bracket One half of the angle bracket will be on the outside of the ceiling bracket and the other half will be on the inside of the ceiling bracket Attach usi...

Страница 16: ...le 2 Attach a short set screw into each post in order to hold utensil rail onto canopy Do the same for the other side c a B t n o r F k Telescopic Rod Installation 1 Install telescopic rod thicker end...

Страница 17: ...selected by presing to decrease and to increase speed level T he display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function...

Страница 18: ...d with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hours of use Re setting...

Страница 19: ...ach Do not use orange cleaners Baffle Filters The Metal Filters fitted by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are re...

Страница 20: ...power is turned off and bulbs are not hot Remove bulb by pressing both ends of the metal retaining clip together the light socket will now extend from the hood allowing you to remove the bulb Be care...

Страница 21: ...n of duct opening is against the wind 5 Using the wrong size of ducting 1 Baffle filter is loose 1 Control board needs to be reset 1 Defective control board 1 Make sure the circuit breaker and the uni...

Страница 22: ...com Halogen Bulb GU 10 120V 50W Z0B 0020 Internal Blower 600 cfm CBI 600 External Blower 1000 cfm CBE 1000 Duct Cover Extension Kit Z1C 00TP List of Parts and Accessories Part Description Part Accesso...

Отзывы: