Zephyr Titan Island AK7742AS Скачать руководство пользователя страница 14

13

Features & Controls - 

Electronic LCD Controls

1. Power / Delay Off

Power Button Function

    On/Off button will turn power on and off for entire hood (fan and lights). The hood will remember the last speed and light level it         

    was turned off at.

Delay Off Button Function

    

With the fan on, press and hold the On/Off button for three seconds. The fan will change to speed 1 and the 10 minute delay off  

    timer will start. A countdown timer will show on the display indicating the time left until the fan and lights automatically turn off.   

    Pressing the On/Off button while the Delay Off Function is enabled will turn the hood off and cancel the Delay Off Function.

ACT

 Verification

    Airflow Control Technology (ACT™) allows the installer to set the maximum blower CFM to align with local codes and regulations.

        To verify the maximum blower CFM:

              With hood off, hold the On/Off button for three seconds. The Display will show if ACT™ is disabled and set to the maximum   

              CFM or if ACT™ is enabled and set to one of the restricted maximum CFM levels of 590, 390 or 290. 

2. Speed Selection

    The 6 speed levels are selected by pressing Fan - to decrease and Fan + to increase speed levels. The Display indicates the    

    speed level selected.

ACT

 Enabled Speed Selections

      

When ACT™ is enabled, the number of fan speeds will be reduced to Maximum 3 speeds. 

3. Lights On/Dim/Off

    Switch lights on by pressing Lights button once, press a second time to dim and again to shut off lights.

4. Display

    The display window indicates speed levels and features such as baffle filter clean reminder, delay off and clean air indicator.

Filter Clean Reminder

    After 30 hours of fan usage the words “Clean grease filters” will show on the Display indicating it is time to clean the filters.

        To Reset: With hood off, hold the Fan - button for 3 seconds until the display words “Clean grease filters” turns off

Clean Air

    Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitchen.

        To enable Clean Air Function:

            With hood off, hold the Fan - button and Fan + button simultaneously for three seconds. The words “CleanAir Function      

            Activated” will illuminate and the fan will turn on speed 1 for 10 minutes. After 10 minutes the fan will turn off and the 4 hour  

            timer will begin.

        To disable Clean Air Function:

            With hood off, hold the Fan - button and Fan + button simultaneously for three seconds. The words “CleanAIr Function    

            Deactivated” will illuminate indicating the function has been disabled.

        When the Clean Air Function is enabled the fan will turn on speed 1 for 10 minutes every 4 hours of non fan usage. After 10   

        minutes the fan will turn off and the 4 hour timer will reset.

        If the user changes the fan speed while the Clean Air Function is in use, the Clean Air Function will stop. If the user presses the  

        On/Off button at any time the 4 hour Clean Air timer will reset.  

Optional Remote Control Pairing

    

To create a unique link between your hood and optional remote control please follow these steps.

        With Hood off, press and hold the Lights button until the Display shows the words “Remote Pairing...” then press any button on  

        the remote, the Display will then show the words “Remote Paired” indicating the remote control pairing is complete.

Power / Delay Off

Adjust 6 Speed Levels

Display 

Lights On/Dim/Off

Содержание Titan Island AK7742AS

Страница 1: ...Use Care and Installation Guide Model number Serial Number www zephyronline com SEP19 0101 Zephyr Ventilation LLC Airflow Control Technology TM C Titan Island AK7736AS AK7742AS AK7748AS...

Страница 2: ...pecifications 8 Mounting the Hood 9 11 PBD 1300A Dual Blower Ducting 12 FEATURES CONTROLS Electronic LCD Controls 13 Optional Remote Control 14 MAINTENANCE Cleaning Filter Removal Lights 15 TROUBLESHO...

Страница 3: ...IRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND...

Страница 4: ...t protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Diagram on product A cable locking connector not supplied might al...

Страница 5: ...t bulbs AK7736AS AK7742AS 4 LED light bulbs AK7748AS 1 8 in round starting collar for single blower ducting 1 Paper ceiling template 1 Hardware package PARTS NOT SUPPLIED Ducting conduit and all insta...

Страница 6: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Страница 7: ...rtant to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its performan...

Страница 8: ...garages All exhaust must be ducted to the outside Use rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Aluminum Tape or Duct Tape Some Ducti...

Страница 9: ...6 36 41 15 16 42 47 15 16 48 17 15 16 36 42 21 5 8 48 4 3 5 16 16 1 4 27 15 16 14 5 16 31 5 8 Standard Min 33 Max 50 Z1C 0077 36 42 Z1C 0177 48 Min 49 Max 78 C L C L 7 7 8 18 36 20 15 16 42 23 15 16 4...

Страница 10: ...s located behind the drywall to reinforce the mounting location FIG A1 Secure 2 M6 x 2 wood screws with washers to points A and B of the paper template FIG B Do not completely tighten screws leave app...

Страница 11: ...t on the top support frame faces the front of the hood where the controls will be located FIG D The key holes on the top support frame should cover the wood screws previously installed in the ceiling...

Страница 12: ...Duct Covers together by magnetic strips 9 Secure Top Duct Covers to Top Support Frame by using 4 3 16 x 1 4 screws 2 screws for each Top Duct Cover FIG H 10 Assemble Bottom Duct Covers together over T...

Страница 13: ...wer to female plugs behind switch panel 1 Disconnect blower plug and white and black power cables 2 Remove 4 screws from interior of hood body attaching single blower plate to top of hood body Remove...

Страница 14: ...der delay off and clean air indicator Filter Clean Reminder After 30 hours of fan usage the words Clean grease filters will show on the Display indicating it is time to clean the filters To Reset With...

Страница 15: ...ing the pairing is complete RF REMOTE FUNCTIONS FIG 1 FIG 2 Blower On Speed Selection Press to power on blower and cycle through all six blower speeds Blower On Power Off By pressing the blowers will...

Страница 16: ...w heat or soaked in hot soapy water Dry filters and re install before using hood Removing Baffle Filters 1 Push filter toward back of range hood using handles 2 Pivot front of filter downward 3 Remove...

Страница 17: ...it is vibrating 1 The blower is not secure in place 1 Tighten the blower in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The...

Страница 18: ...nd place inside the hood body below the wiring diagram or in another clearly visible location NOTE After re positioning the jumper and powering on the hood the CFM cannot be changed again To verify if...

Страница 19: ...18 www zephyronline com Wiring Diagrams ACT 590 CFM Fan Max 175W 2 6A ACT 390 CFM Fan Max 94W 1 4A ACT 290 CFM Fan Max 63W 0 9A...

Страница 20: ...onal Accessories Duct Cover Extension 36 42 Z1C 0077 Duct Cover Extension 48 Z1C 0177 Dual Internal Blower PBD 1300A Make Up Air Kit Single Blower MUA008A Make Up Air Kit Dual Blower MUA010A To order...

Страница 21: ...ith this warranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR...

Страница 22: ...phyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures warrant...

Отзывы: