Important Safety Notice

3

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

CAUTION

To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,
attics, crawl spaces or garages.

OPERATION

Always leave safety grilles and fi lters in place. Without these components, operating blowers could catch onto hair, fi ngers 
and loose clothing.

The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, 
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to 
negligence and the warranty of the unit automatically expires due to improper maintenance.

*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.

ELECTRICAL REQUIREMENTS

Important:

Observe all governing codes and ordinances.

It is the customer’s responsibility:
-  To contact a qualifi ed electrical installer.
-  To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 

latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and 
all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualifi ed electrician determine that the 
ground path is adequate.

Do not ground to a gas pipe.

Check with a qualifi ed electrician if you are not sure the range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit 
protected by a 15 or 20 ampere circuit breaker or time delay fuse.  Wiring must be 2 wire with ground.  Please also refer to 
Electrical Diagram on product.

A cable locking connector (not supplied) might also be required by local codes.  Check with local requirements, purchase 
and install appropriate connector if necessary.

Содержание Tempest II AK7500ASX

Страница 1: ...and Installation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer MAY12 0501 2012 Zephyr Corporation Tempest II AK7500ASX AK7536ASX AK7548ASX READ AND SAVE THESE INS...

Страница 2: ...www zephyronline com...

Страница 3: ...ations 8 Electrical 9 Mounting the Range Hood 10 CBIxxxB and PBI 1100A Internal Blowers 11 CBI xxxB Horizontal Ducting Conversion 12 13 Remote Blower Preparation 14 FEATURES CONTROLS Touch Controls Fe...

Страница 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Страница 5: ...To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2...

Страница 6: ...ntal ducting 2 Blower brackets for single blower horizontal ducting 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if requir...

Страница 7: ...Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15...

Страница 8: ...s important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its per...

Страница 9: ...ll exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Install...

Страница 10: ...8 24 30 30 36 42 48 12 10 24 4 18 1 3 8 9 15 16 2 3 4 2 3 16 1 1 8 8 9 16 13 3 16 2 5 16 6 7 16 2 2 1 16 CL 5 9 16 ext blwr k o elec k o 2 11 16 3 7 16 1 3 16 elec k o CL top side back 4 5 16 10 trans...

Страница 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere ci...

Страница 12: ...ontally ducting hood refer to hood specifications on page 8 for cut out dimensions 6 Hang hood on wood board and secure using 4 M4 x 16 screws 7 Install blower s Turn to page 11 for blower installatio...

Страница 13: ...Secure plate to hood with 2 10x3 16 screws blower pictured is a PBI 1100A 2 Connect male end of blower wire to female plug in the hood plug is located inside the hood behind the control panel 3 CBI x...

Страница 14: ...ound blower opening on blower plate with 6 round metal cap included with the CBI xxxB Secure with 3 3 5x8 screws 4 On the back of the hood remove the 6 screws holding the rectangular cap to the hood 5...

Страница 15: ...Attach blower brackets to blower with 4 10x3 16 screws 2 screws for each bracket 8 Place blower into round end of 6 round transition adapter Attach brackets on blower to blower plate with 4 3 5x8 scre...

Страница 16: ...secure by turning clockwise 4 Connect 6 pin male connector from remote blower wiring to 6 pin female connector on control board wire inside hood Secure green ground wire from external blower wiring t...

Страница 17: ...Off This is used for programmed shut down of blower and lights 5 minutes after the function is activated Press once a dot displays in the lower right hand side of display indicating the function is o...

Страница 18: ...ers are cleaned and re installed with hood off Press and hold for approximately 5 seconds the display will appear hold for approximately 5 seconds until on display disappears The filter clean reminder...

Страница 19: ...in Stainless Steel Baffle Filters The stainless steel baffle filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required to be clean...

Страница 20: ...by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately...

Страница 21: ...od is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb is loose 2 Tighten the l...

Страница 22: ...Blower PBI 1100A External Blower CBE 1000 In Line Blower PBN 1000A Heat Lamp Kit 30 AK0700B Heat Lamp Kit 36 AK0706B Heat Lamp Kit 48 AK0708B Back Splash 30 AK0710 Back Splash 36 AK0716 Back Splash 4...

Страница 23: ...ll labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABL...