REPLACING LIGHT BULBS

CAUTION: Light bulb becomes extremely hot when turned on.

DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.

Make sure all power is turned off and bulbs are not hot.

Remove by turning bulb counter clockwise. 

Note:

Bulb does not unscrew; it turns 60 degrees, stops and 

falls out.

If bulbs are diffi cult to turn due to prolonged use, fi rmly attach a glass suction cup approximately the 
diameter of the bulb or use a rubber/latex glove and turn counter clockwise.

Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen.

For Zephyr part numbers please turn to page 20 of the manual.

Maintenance – 

Lights

Содержание Tempest II AK7500ASX

Страница 1: ...and Installation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer MAY12 0501 2012 Zephyr Corporation Tempest II AK7500ASX AK7536ASX AK7548ASX READ AND SAVE THESE INS...

Страница 2: ...www zephyronline com...

Страница 3: ...ations 8 Electrical 9 Mounting the Range Hood 10 CBIxxxB and PBI 1100A Internal Blowers 11 CBI xxxB Horizontal Ducting Conversion 12 13 Remote Blower Preparation 14 FEATURES CONTROLS Touch Controls Fe...

Страница 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Страница 5: ...To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2...

Страница 6: ...ntal ducting 2 Blower brackets for single blower horizontal ducting 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if requir...

Страница 7: ...Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15...

Страница 8: ...s important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its per...

Страница 9: ...ll exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Install...

Страница 10: ...8 24 30 30 36 42 48 12 10 24 4 18 1 3 8 9 15 16 2 3 4 2 3 16 1 1 8 8 9 16 13 3 16 2 5 16 6 7 16 2 2 1 16 CL 5 9 16 ext blwr k o elec k o 2 11 16 3 7 16 1 3 16 elec k o CL top side back 4 5 16 10 trans...

Страница 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere ci...

Страница 12: ...ontally ducting hood refer to hood specifications on page 8 for cut out dimensions 6 Hang hood on wood board and secure using 4 M4 x 16 screws 7 Install blower s Turn to page 11 for blower installatio...

Страница 13: ...Secure plate to hood with 2 10x3 16 screws blower pictured is a PBI 1100A 2 Connect male end of blower wire to female plug in the hood plug is located inside the hood behind the control panel 3 CBI x...

Страница 14: ...ound blower opening on blower plate with 6 round metal cap included with the CBI xxxB Secure with 3 3 5x8 screws 4 On the back of the hood remove the 6 screws holding the rectangular cap to the hood 5...

Страница 15: ...Attach blower brackets to blower with 4 10x3 16 screws 2 screws for each bracket 8 Place blower into round end of 6 round transition adapter Attach brackets on blower to blower plate with 4 3 5x8 scre...

Страница 16: ...secure by turning clockwise 4 Connect 6 pin male connector from remote blower wiring to 6 pin female connector on control board wire inside hood Secure green ground wire from external blower wiring t...

Страница 17: ...Off This is used for programmed shut down of blower and lights 5 minutes after the function is activated Press once a dot displays in the lower right hand side of display indicating the function is o...

Страница 18: ...ers are cleaned and re installed with hood off Press and hold for approximately 5 seconds the display will appear hold for approximately 5 seconds until on display disappears The filter clean reminder...

Страница 19: ...in Stainless Steel Baffle Filters The stainless steel baffle filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required to be clean...

Страница 20: ...by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately...

Страница 21: ...od is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb is loose 2 Tighten the l...

Страница 22: ...Blower PBI 1100A External Blower CBE 1000 In Line Blower PBN 1000A Heat Lamp Kit 30 AK0700B Heat Lamp Kit 36 AK0706B Heat Lamp Kit 48 AK0708B Back Splash 30 AK0710 Back Splash 36 AK0716 Back Splash 4...

Страница 23: ...ll labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABL...

Отзывы: