9
Spruce Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting Height, Clearance, & Ducting
30” min.
36” max
.
36”
A minimum of 10” round duct is recommended to
maintain maximum air flow efficiency.
Always use rigid type metal ducts only. Flexible
ducts could restrict air flow by up to 50%.
Also use the ducting calculation sheet (on page
8) to compute total available duct run when using
elbows, transitions and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 30”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and fire hazard; while hoods
mounted too high will be hard to reach and will lose
its performance and efficiency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood
mounting height above range. Always check your local codes for any differences.
For shipment and installation damages:
►
Please fully inspect unit for damage before installation.
►
If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
►
If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
►
If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.