18
Siena Use, Care, and Installation Guide
S I E N A
WA L L
C O R E
Installation Instructions
Recirculating Kit Installation
(required if no ducting is used)
For detailed installation instructions, please refer to the manual included with the recirculating kit.
The kit includes the charcoal filters, charcoal filter brackets, and air diverter plate.
Hood Model
Recirculating Kit
Part Number
Filters in
Package
Charcoal Filter
Replacement Part
Number
Quantity to
Order
ZSI-E30CS
ZRC-00SI
2
Z0F-C091
2
ZSI-E36CS
ZRC-00SI
2
Z0F-C091
2
1. Secure air diverter plate to wall below duct cover
bracket, FIG. D
2. Remove baffle filters from hood. Place charcoal
filter over the back side of baffle filter.
3. Secure charcoal filters to back side of baffle filters
by three brackets for each filter.
4. Re-install baffle filters.
5. Charcoal filters must be replaced every 120 hours
of use (or approximately every 3 to 4 months based
on an average of 1 - 2 hours of daily cooking time).
DO NOT WASH CHARCOAL FILTERS. Charcoal filters
may need to be changed more often depending on
cooking habits.
FIG. D