1
START APPLICATION
START APPLICATION
2
SELECT LIVE MODE
6
FORWARD LEAN
7
POSTURE CHECK
4
DATA STABILISATION TIMES
FROM DEVICE POWER-ON
Heart Rate: 5 seconds
Breathing Rate: 30
– 45
seconds
Core Temperature; 1 second
Activity/Posture: 1 second
3
WAIT 1-2 minutes
It takes the Gateway 1-2 minutes for all
network connections to establish and
stabilize. During this time BioGauges may
switch from black to blue to ROG colours
intermittently
2.5 Live Screen Operation Checks
5
STATUS INDICATION ON START UP
SENDING ESTABLISHING DEVICE NOT DATA DATA
REQUEST CONNECTION WORN (CHECK) STABILIZING STABILIZING