18
PRW24F02CPG, PRB24F01BPG Use, Care, and Installation Guide
F U L L S I Z E C O O L E R
S I N G L E & D U A L Z O N E
P R E S R V ™
Installation Instructions
Installation Clearance Requirements
When installing the cooler, follow the recommended spacing dimensions shown.
Ź
For proper clearance of the electrical plug, allow at least 1” of clearance at the back as shown in
the diagram.
Ź
An installation next to a wall will require a minimum 7” door clearance to accommodate the
Zephyr handle and to prevent the shelf from rubbing against the gasket. If using a custom handle
that is shallower, the distance may be reduced.
Ź
The cabinet should allow at least 24” for the width and 69-3/4” for the height to accommodate
the cooler.
Ź
The power cable is located on the back right of the unit and has a length of 72” to accommodate
multiple outlet locations.
Ź
Once you are ready to install the unit, you must adjust the feet to level the coolers. An improperly
leveled drawer may not close properly.
Ź
The installation should allow the unit to be pulled forward for servicing, if necessary.
7
” Min.
1” Min.
24” Min.
69
-
3/4
” Min.