background image

13

In

s

ta

ll

a

ti

on

-

Mo

u

n

ti

n

g

H

o

o

d

gap between
bracket and
wall

Top

Bottom

1. Place wall bracket on line C. Position top of wall bracket so it is even with the 21” mounting spread. Make

sure bracket is attached to wall as shown in the diagram. The top of the wall bracket should have a gap between
it and the wall. The bottom should be flush against the wall. Use (3) 2” wood screws to attach bracket to wall. Use
anchors if not mountingto studs.

2. Lift hood onto wall bracket, there is a lip on the back of the hood which will rest on the wall bracket. Secure in

place by *screwing (2) screws with washers through hood into the wall. There are two holes at the bottom inside
the hood in which to do this.

3. Place telescopic duct covers on top of hood and extend top duct cover to the ceiling bracket. Attach duct cover to

ceiling bracket with the providedscrews.

4. Run duct work down to top of motor. Attach electrical wiring from ceiling to wiring on top of motor housing. (slide

duct cover up towards ceiling to gain access to the motor housing)

* Note

:

If installing onto drywall only with no wall studs present, attach E Z anchors (not provided) into the wall.

Please see page 15 for external blower installation instructions.

B

A

C

Attach screws to both
sides of the duct cove

rs

and secure to ceiling 

bracket.

Electrical

10”

Содержание Okeanito COK-E36SX

Страница 1: ...Okeanito COK E36SX COK E42SX COK E48SX Use Care and Installation Guide MAY07 0101 www zephyronline com Model number Serial number Date of Purchase Sales Dealer Zephyr Corporation...

Страница 2: ...www zephyronline com...

Страница 3: ...on Sheet Mounting Height and Clearance Ducting Specifications Internal Blower Preparing Hood for External Blower Mounting the Hood FEATURES CONTROLS Controls Overview MAINTENANCE Cleaning Lights TROUB...

Страница 4: ...DO NOT USE WATE R includingwet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate...

Страница 5: ...Washers 4 1 2 Screws 5x15mm 4 10mm Washers 1 SMALL HARDWARE PACKET 1 T ool 3 Short Set Screws 4 on 48 Model 1 HARDWARE PACKET EXTERNAL BLOWER KIT 1 8 Collar 1 External Blower Wiring Box with Wires 10...

Страница 6: ...nd straight 1 Ft x Ft Subtotal column 1 Duct pieces Total Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft 7 Round wall cap with damper 30 Ft x Ft 7 Round 900 elbow 15 Ft x Ft 7...

Страница 7: ...pute total duct work ALWAYS when possible reduce the number or transitions and turns If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from opening...

Страница 8: ...Blower External Blower WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use singl...

Страница 9: ...n Specifications R I H P E Z Y B N G I S E D G N E H C O G O L 19 3 4 19 3 4 10 36 42 48 22 5 8 11 7 8 95 16 5 8 13 3 8 14 1 2 15 5 36 8 42 3 1 2 48 6 9 3 16 6 1 5 O 8 5 16 8 1 4 R 2 3 1 1 4 R 2 3 5 1...

Страница 10: ...shown using the provided 1 2 5x15mm screws with washers 3 P osition capacitor box as shown 4 Secure capacitor bo x to hood using the provided 1 2 self tapping screws ATTENTION The following are intru...

Страница 11: ...finish installation of capacitor box Refer to Fig A on previous page 7 Attach short capacitor connector to blower connector 8 Attach long capacitor connector to control board connector 9 Use plastic t...

Страница 12: ...on with external blower model CBE 1000 For instructions on installing internal blower model CBI 600 please turn to page 8 NOTE Please refer to the CBE 1000 manual for external blower mounting instruct...

Страница 13: ...side hood 9 Attach grounding wire from external blower wiring box to grounding screw of the junction box Refer on Fig A in diagram below 10 Final view of external blower preparation Continue to page 1...

Страница 14: ...ll and insert provided anchors into the marked holes Cut out inside diameter of the ceiling bracket to fit the 6 or 8 round duct work Attach bracket to ceiling with 2 screws provided 7 Prepare duct wo...

Страница 15: ...e in place by screwing 2 screws with washers throughhood into the wall There are two holes at the bottominside the hood in which to do this 3 Place telescopic duct covers on top of hood and extend top...

Страница 16: ...ting point to attach the first utensil rail post After the first post is lined up with the hole gently slide the rest of the rail onto the canopy note be careful not to scratch the stainless steel whe...

Страница 17: ...lection The 3 speed levels are selected by pressing to decrease and to increase speed level The display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights...

Страница 18: ...d with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hours of use Re setting...

Страница 19: ...e Metal Filters fitted by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are requiredto be kept clean Filters should be cleaned...

Страница 20: ...he bulb B e careful when releasing retain clip as it is under pressure to hold it in place Replacement halogen bulbs are available at most stores which sell light bulbs Purchase type GU 10 120 V 50W T...

Страница 21: ...against the wind 5 Using the wrong size of ducting 1 Baffle filter is loose 1 Control board needs to be reset 1 Defective control board 1 Make sure the circuit breaker and the unit s power is ON 2 Che...

Страница 22: ...Part Halogen Bulb GU 10 120V 50W Z0B 0020 Incadescent Bulb T29 127V 40 W Z0B 0003 Internal Blower 600 cfm CBI 600 External Blower 1000 cfm CBE 1000 Duct Cover Extension Kit Z1C 00OK Accessory Descrip...

Страница 23: ...ices outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The natural wear of finish and...

Отзывы: