background image

WWW.ZEPHYRONLINE.COM

DEC20.0201

Airflow  Control  Technology

TM

C  

EN   Use, Care, and Installation Guide

 

FR   Guide d’utilisation, d’entretien et d’installation

Monsoon Connect

AK9428BS, AK9434BS, AK9440BS, AK9446BS

Содержание Monsoon Connect

Страница 1: ...WW ZEPHYRONLINE COM DEC20 0201 Air ow Control Technology TM C Monsoon Connect AK9428BS AK9434BS AK9440BS AK9446BS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installatio...

Страница 2: ...2 Monsoon Connect Use Care and Installation Guide MONSOON CONNECT INSERT CORE...

Страница 3: ...g 9 10 Ducting Options 11 Hood Speci cations 12 Electrical Supply 13 Cable Lock 13 Preparation Installation 14 16 Horizontal Ducting Preparation 17 19 PBD 1300B Dual Blower Installation 20 22 Features...

Страница 4: ...annot be locked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive pr...

Страница 5: ...thin walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must b...

Страница 6: ...and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Dia...

Страница 7: ...led 4 LumiLight LED 6W pre installed AK9446BS only 1 Single blower motor pre installed 1 8 round adapter with damper 2 Horizontal ducting blower mount brackets 1 Top rectangular cover plate 1 Hardware...

Страница 8: ...x Ft Ft Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent...

Страница 9: ...9 Monsoon Connect Use Care and Installation Guide ZEPHYRONLINE COM Installation Instructions Mounting Height Clearance Ducting 24 min 34 max 36...

Страница 10: ...nimum mount height between range top to hood bottom should be no less than 24 Maximum mount height should be no higher than 34 It is important to install the hood at the proper mounting height Hoods m...

Страница 11: ...ti ed Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust must be ducted to the outside unless us...

Страница 12: ...3 16 48 17 7 8 30 only 5 9 16 36 42 48 6 1 8 C L 30 9 1 4 36 11 7 8 42 14 7 8 48 17 7 8 2 elec k o 10 3 8 elec k o C L 5 1 2 7 11 16 12 19 3 8 12 3 remote antenna 7 11 16 9 15 16 9 1 2 14 3 16 8 1 16...

Страница 13: ...n cord or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an individua...

Страница 14: ...8 8 x 1 2 stainless steel screws 4 screws in the front and 4 screws in the sides FIG C 28 3 8 or 34 3 8 or 40 3 8 or 46 1 4 19 3 8 cut out AK9428 AK9434 AK9446 AK9440 1 4 po 1 1 8 po Make sure the su...

Страница 15: ...tion 1 Remove baffle lters by 1 Pulling lter toward front of liner 2 Pivoting rear of lter down 2 Remove grease tray by 1 Pulling up on tray to release from bottom panel 2 Lifting tray out of liner bo...

Страница 16: ...m Panel Screws 2 1 4 Remove bottom panel by 1 Removing 2 screws from left and right sides of bottom panel 2 Pulling bottom panel toward front of liner to release from locking tabs 6 Vertical ducting p...

Страница 17: ...ntal Ducting Preparation 1 Follow steps 1 to 4 from pages 15 and 16 Remove blower molex plug 2 Remove blower from liner by removing the 4 3 16 x 3 8 screws from the top of the liner Set screws aside f...

Страница 18: ...ner secure plate to top of liner with 2 3 16 x 3 8 screws At this point install the liner into the cabinet by following the steps on page 14 step 4 After liner installation continue on page 18 5 From...

Страница 19: ...ated on the interior back wall of the liner 2 Pivot top horizontal ducting bracket to meet captive nuts on interior back wall 1 2 1 8 Secure blower to captive nuts on interior back wall of liner with...

Страница 20: ...the instructions below PBD 1300B dual blower kit compatible only with AK9434BS AK9440BS and AK9446BS 1 Remove the baffle lters and if applicable remove the side panels Disconnect blower plug 2 Remove...

Страница 21: ...l previously removed blower onto one side of dual blower plate and attach by 4 previously removed screws from step 2 6 Install blower from PBD 1300B kit onto other side of dual blower plate by 4 3 16...

Страница 22: ...al blower K and white single pin power cord F to dual blower PCB NOTE To secure the 10 transition adapter to top of hood a cut out of 14 1 2 width x 10 1 2 depth will need to be made in the cabinet bo...

Страница 23: ...until the fan and lights are turned off CONTROL ICONS Power Press the power icon to power on or off the fan and lights The hood has a memory function to remember the last used settings for the fan and...

Страница 24: ...TED or WIFI DISCONNECTED will appear on the LCD display whenever the connection changes which will be managed via the Zephyr Connect app While the fan is on press and hold for 3 seconds to enable the...

Страница 25: ...ovides the option to reset the reminder Recirculating Mode Charcoal Filter Replacement Reminder Hold and for 3 seconds to enable or disable recirculating mode which will remind you to replace the char...

Страница 26: ...ct information The Zephyr Connect app is available on iOS devices using iOS 11 0 or later or Android devices using Android version 8 or later Visit the Apple App Store or Google Play Store for more in...

Страница 27: ...Start Enable Hood Name Delay Off Timer Enable delay off timer for 10 minutes After 10 minutes the hood will power off Alexa Stop Disable Hood Name Delay Off Timer Disable delay off timer Control Type...

Страница 28: ...ause undesired operation Synchronization To create a unique link between your hood and remote control please follow these steps 1 With hood off press and hold on the hood until the controls display RE...

Страница 29: ...utlet for easy storage Note The remote holder does not charge the RF remote Maximum remote control communication distance is 15 feet from the liner RF Remote Maintenance Clean the remote control using...

Страница 30: ...eaners to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth or micro ber cloth and buff in the direction of the stainless steel grain The lters are intend...

Страница 31: ...es 2 Pivot back of lter upwards so it is angled in the liner 3 Push lter into channel on back of liner to lock into place Removing the Grease Tray Grease tray has a hooked lip that attaches to bottom...

Страница 32: ...ontact Zephyr to order replacement parts See the list of parts and accessories page for part numbers and contact information LED Removal FIG H 1 Remove baffle lters 2 Remove light panel by ve screws 3...

Страница 33: ...ering on the hood the CFM cannot be changed again CAUTION Some local codes limit the maximum amount of CFM a range hood can move ACT allows you to control the maximum blower CFM of select Zephyr Venti...

Страница 34: ...lation 4 Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below the wiring diagram or in another clearly visible location To verify if your inst...

Страница 35: ...ble Remove both spacer panels by 2 screws for each spacer panel 3 Remove 5 screws attaching light panel FIG I 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 Jumper 7 8 DEFAULT POSITIO...

Страница 36: ...agram WIFI WHITE B W BLACK BLACK BLACK BLACK BLACK BLACK BLACK B W WHITE WHITE WHITE WHITE WHITE GREEN BODY MOTOR 1 MOTOR 2 WHITE K Single Blower Dual Blower A Wi Fi connection wire C Power wire for e...

Страница 37: ...W BLACK BLACK BLACK BLACK BLACK BLACK BLACK B W WHITE WHITE WHITE WHITE WHITE GREEN BODY MOTOR 1 MOTOR 2 WHITE K Single Blower Dual Blower A Wi Fi connection wire B LED PCB wire C Power wire for expa...

Страница 38: ...the blower is too hot to operate and shuts the blower down The blower will function properly after the thermally protected system cool down Damaged capacitor Change the capacitor Blower molex plug pin...

Страница 39: ...ge the lter Spring clip is broken on the lter Change the spring clip RF Remote control does not work Battery is dead Replace battery with type A23 12v Poor communication with the hood Remote control m...

Страница 40: ...cking the pathway to the range hood Walls may reduce signal strength User cannot change Wi Fi connections The range hood and user s phone have already connected Enter Bluetooth settings and forget the...

Страница 41: ...e ZEPHYRONLINE COM List of Parts Accessories Description Part Number Replacement Parts LumiLight LED 6W Z0B0047 Baffle Filter each 50210039 Optional Accessories RF Remote Control 14000005 To order par...

Страница 42: ...42 Monsoon Connect Use Care and Installation Guide MONSOON CONNECT INSERT CORE Notes...

Страница 43: ...l labor costs associated with this warranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION T...

Страница 44: ...e take a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways...

Страница 45: ...WW ZEPHYRONLINE COM DEC20 0201 Air ow Control Technology TM C EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation Monsoon Connect AK9428BS AK9434BS AK9440BS AK9446B...

Страница 46: ...2 Monsoon Connect Guide d utilisation d entretien et d installation INS RER CORE MONSOON CONNECT...

Страница 47: ...Options de conduits 11 Sp ci cations de la hotte 12 Fourniture lectrique 13 Raccord de c ble 13 Pr paration et installation 14 16 Pr paration des conduits horizontaux 17 19 Installation du double ven...

Страница 48: ...abricant b Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle L...

Страница 49: ...t normes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e de...

Страница 50: ...te une alimentation lectrique de 120 V 60 Hz et est connect un circuit de d rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blag...

Страница 51: ...s par les codes locaux T l commande RF Moteur double soufflante Pi ces fournies Quantit Partie 1 Ins rer le corps de la hotte 2 Filtres chicane 3 Filtres chicane AK9446BS uniquement 2 LumiLight LED 6...

Страница 52: ...r x Nombre utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air conve...

Страница 53: ...9 Monsoon Connect Guide d utilisation d entretien et d installation ZEPHYRONLINE COM Instructions d installation Hauteur de montage d gagement et gaine 24 po min 34 po max 36 po...

Страница 54: ...re les deux La hauteur de montage minimale entre le haut de la cuisini re et le bas de la hotte ne doit pas tre inf rieure 24 po La hauteur de montage maximale ne doit pas d passer 34 po Il est import...

Страница 55: ...e d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages Tout l chappement doit tre canalis vers l ext...

Страница 56: ...L C 30 po 9 1 4 po 36 po 11 7 8 po 42 po 14 7 8 po 48 po 17 7 8 po 2 po entr e defoncable 10 3 8 po entr e defoncable L C 5 1 2 po 7 11 16 po 12 po 19 3 8 po 12po 3 po antenne distance 7 11 16 po 9 15...

Страница 57: ...d rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 ls avec terre Veuillez galement vous r f rer au sch ma lectr...

Страница 58: ...4 vis l avant et 4 vis sur les c t s FIG C 28 3 8 po 34 3 8 po 40 3 8 po 46 1 4 po 19 3 8 po coup AK9428 AK9434 AK9446 AK9440 1 4 po 1 1 8 po Assurez vous que la surface sur laquelle vous xez la doubl...

Страница 59: ...ecteurs en 1 Tirant le ltre vers l avant de la doublure 2 Pivotement de l arri re du ltre vers le bas 2 Retirez le plateau graisse en 1 Tirant sur le plateau pour le d gager du panneau inf rieur 2 So...

Страница 60: ...irez le panneau inf rieur en 1 Retirez les 2 vis des c t s gauche et droit du panneau inf rieur 2 Tirer le panneau inf rieur vers l avant de la doublure pour le d gager des languettes de verrouillage...

Страница 61: ...taux 1 Suivez les tapes 1 4 des pages 15 et 16 Retirez le bouchon molex du ventilateur 2 Retirez le ventilateur de la gaine en retirant les 4 vis 3 16 x 3 8 du haut de la gaine Mettez les vis de c t p...

Страница 62: ...ec 2 vis 3 16 x 3 8 ce stade installez la doublure ce stade installez la doublure dans l armoire en suivant les dans l armoire en suivant les tapes de la page 14 tape tapes de la page 14 tape 4 Apr s...

Страница 63: ...l sup rieur pour qu il rencontre les crous captifs sur la paroi arri re int rieure 1 2 1 8 Fixez le ventilateur aux crous captifs sur la paroi arri re int rieure du rev tement avec 8 vis 3 16 x 3 8 4...

Страница 64: ...oufflante PBD 1300B compatible uniquement avec AK9434BS AK9440BS ou AK9446BS 1 Retirez les ltres d ecteurs et le cas ch ant retirez les panneaux lat raux D branchez la che du ventilateur 2 Retirez les...

Страница 65: ...c t de la plaque de ventilateur double et xez le l aide des 4 vis pr c demment retir es de l tape 2 6 Installez le ventilateur du kit PBD 1300B sur l autre c t de la plaque de ventilateur double l aid...

Страница 66: ...t le cordon d alimentation blanc une broche F au PCB double ventilateur REMARQUE Pour xer l adaptateur de transition de 10 po au haut de la hotte une d coupe de 14 1 2 po de largeur x 10 1 2 po de pro...

Страница 67: ...es ic nes ne dispara tront pas tant que le ventilateur et les lumi res ne seront pas teints IC NES DE CONTR LE Allumer Appuyez sur l ic ne d alimentation pour allumer ou teindre le ventilateur et les...

Страница 68: ...IFI DISCONNECTED appara tront sur l cran LCD chaque fois que la connexion change ce qui sera g r via l application Zephyr Connect Retard automatique d sactiv Pendant que le ventilateur est en marche m...

Страница 69: ...cation Zephyr Connect offre la possibilit de r initialiser le rappel Maintenez et pendant 3 secondes pour activer ou d sactiver le mode de recirculation qui vous rappellera de remplacer le ltre charbo...

Страница 70: ...it L application Zephyr Connect est disponible sur les appareils iOS utilisant iOS 11 0 ou version ult rieure ou les appareils Android utilisant la version Android 8 ou ult rieure Visitez l Apple App...

Страница 71: ...Start Enable Hood Name Delay Off Timer Activer la minuterie d arr t pendant 10 minutes Apr s 10 minutes la hotte s teint Alexa Stop Disable Hood Name Delay Off Timer D sactiver le temporisateur d arr...

Страница 72: ...e et la t l commande veuillez suivre ces tapes 1 Avec le capot teint appuyez et maintenez sur le capot jusqu ce que les commandes affichent REMOTE PAIRING 2 Appuyez sur un bouton de la t l commande et...

Страница 73: ...e Remarque le support de t l commande ne charge pas la t l commande RF La distance de communication maximale de la t l commande est de 15 pieds de la doublure Maintenance distance RF Nettoyez la t l c...

Страница 74: ...non abrasif pour polir et polir le lustre et le grain de l acier inoxydable Frottez toujours l g rement avec un chiffon en coton propre ou en micro bres et polissez dans le sens du grain de l acier in...

Страница 75: ...ter l arri re du ltre vers le haut pour qu il soit inclin dans la doublure 3 Poussez le ltre dans le canal l arri re de la doublure pour le verrouiller en place Retrait du bac graisse Le plateau grais...

Страница 76: ...pi ces de rechange Voir la page de la liste des pi ces et accessoires pour les num ros de pi ces et les coordonn es Retrait de la LED LumiLight FIG H 1 Retirer les ltres d ecteurs 2 Retirez le panneau...

Страница 77: ...ng AVERTISSEMENT Technologie de contr le du d bit d air ACT Certains codes locaux limitent la quantit maximale de CFM qu une hotte de cuisini re peut d placer ACT vous permet de contr ler le CFM maxim...

Страница 78: ...uivez l installation de la hotte 4 Retirez l autocollant CFM en aluminium appropri inclus avec la documentation de la hotte et placez le l int rieur du corps de la hotte sous le sch ma de c blage ou u...

Страница 79: ...t par 2 vis pour chaque panneau d espacement 3 Retirez les 5 vis xant le panneau lumineux FIG I 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 Cavalier 7 8 POSITION PAR D FAUT 1 3 5 7...

Страница 80: ...NOIR NOIR BLANC NOIR BLANC BLANC BLANC BLANC BLANC VERT CORPS MOTEUR 1 MOTEUR 2 BLANC K Souffleur simple Double ventilateur A Fil de connexion Wi Fi C C ble d alimentation pour PCB d extension D C ble...

Страница 81: ...NC BLANC BLANC BLANC BLANC VERT CORPS MOTEUR 1 MOTEUR 2 BLANC K Souffleur simple Double ventilateur A Fil de connexion Wi Fi B Fil de carte PCB de LED C C ble d alimentation pour PCB d extension D C b...

Страница 82: ...ventilateur Le ventilateur fonctionnera correctement apr s le refroidissement du syst me thermiquement prot g Condensateur endommag Changez le condensateur La broche de la prise molex du ventilateur...

Страница 83: ...ltre Changer le clip ressort La t l commande RF ne fonctionne pas La batterie est morte Remplacez la batterie par un type A23 12v Mauvaise communication avec la hotte La t l commande doit tre moins de...

Страница 84: ...ent r duire la puissance du signal L utilisateur ne peut pas modi er les connexions Wi Fi La hotte et le t l phone de l utilisateur sont d j connect s Entrez les param tres Bluetooth et oubliez l appa...

Страница 85: ...ONLINE COM Liste des pi ces et accessoires La description Num ro d article Pi ces de rechange LumiLight LED 6 W Z0B0047 Filtre chicane chacun 50210039 Accessoires optionnels T l commande RF 14000005 P...

Страница 86: ...42 Monsoon Connect Guide d utilisation d entretien et d installation INS RER CORE MONSOON CONNECT Remarques...

Страница 87: ...is de d placement du technicien votre domicile pour que le Produit soit r par enlev ou r install Un an apr s la date d achat originale du Produit vous tes galement responsable de tous les frais de mai...

Страница 88: ...lle produit au www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la...

Отзывы: