1.  Measure from range top to hood bottom and mark line A.  

(28” minimum from range top) .

2.  Plum and mark center line.

3.  Mark mounting height line B. (15-3/8” from line A)

4.  Mark mounting spread from C/L. (8-7/8”) 

5.  Fasten (2) M4 x 1-1/2” screws into studs on line B but 

do not tighten all the way.  

Note: Wood blocking may 

need to be added behind the drywall if no studs are 
present.  Wall anchors may also be used but check 
local codes before using wall anchors.

6.  Remove the (2) metal mesh fi lters.

7.   Remove the (2) charcoal fi lter brackets located inside 

the hoood behind the metal mesh fi lters.  Each bracket is 
secured with (4) 3/16 x 6 Philips head screws.  

Note: If 

you are not recirculating the hood you may discard 
the charcoal brackets.

8.  Hang hood onto the mounting screws and hand tighten 

each screw. (fi g A) Secure third M4 x 1-1/2” screw 
through inside of hood into wall for extra support. (fi g A2) 

9.  Center and attach duct cover mounting bracket to wall 

just below the ceiling or soffi t using (2) M4 x 1” screws.

10. Install electrical and duct work.  Seal duct work with 

aluminum duct tape.

11. Power up hood and check for leaks around duct tape.

12. Place telescopic duct covers onto hood and extend 

inner (top) duct cover upwards and secure to duct cover 
bracket using (2) M3.5 x 8 screws. Secure bottom duct 
cover to hood body by also using (2) M3.5 x 8 screws.

* If using hood in recirculating mode you must secure the air 

diverter plate onto wall before installing duct work and 
duct covers.  Turn to page 10 for more details.

15-3/8

Brackets are 

pre-installed

fig. A

fig. A2

CAUTION: At least two installers are

required due to the weight and size of the
hood.

!

WARNING: Electrical wiring must be done by a qualified person(s) in

accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.

!

Installation – 

Mounting the Hood

Cable Lock

Cable Lock

A cable locking connector (not supplied) might 
be required by local codes.  Check with local 
requirements and codes, purchase and install 
appropriate connector if necessary.

Содержание Milano WallZMI-M90AG

Страница 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number FEB09 0201 Zephyr Corporation Milano Wall ZMI M90AS ZMI M90AG...

Страница 2: ...www zephyronline com...

Страница 3: ...ng Options 7 Hood Specifications 8 Mounting the Range Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Touch Controls 11 Charcoal Filter Replace Reminder 12 Metal Mesh Filter Clean Reminder 13 MAINT...

Страница 4: ...NS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not...

Страница 5: ...l installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and...

Страница 6: ...odes Duct cover extension accessory Z1C 00MI Recirculating kit accessory ZRC 0040 HARDWARE PACKAGE CONTENTS MODELS ZMI M90AS ZMI M90AG 1 Suction Cup 1 Hood body with internal blower 2 Metal mesh filte...

Страница 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Страница 8: ...available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Minimum Mounting Height D...

Страница 9: ...ng option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Op...

Страница 10: ...8 www zephyronline com Installation Hood Specifi cations 23 15 16 min ducted 26 1 2 min recirc 30 max 49 10 1 2 elec k o 4 8 1 2 35 7 16 14 20 1 2 6 top of hood front of hood side of hood...

Страница 11: ...just below the ceiling or soffit using 2 M4 x 1 screws 10 Install electrical and duct work Seal duct work with aluminum duct tape 11 Power up hood and check for leaks around duct tape 12 Place telesco...

Страница 12: ...recirculating kit per the part number above 2 Secure air diverter plate to wall below duct cover bracket FIG B Run 6 ducting from top of hood and secure to air diverter plate See manual included with...

Страница 13: ...after 15 minutes 4 Lights On Dim Off Switch lights on by pressing once press a second time to dim and again to shut off lights 5 Display Window The display window indicates speed levels and features s...

Страница 14: ...d count usage time and indicate by a flashing when charcoal filter replacements are needed C Setting the Filter Change Reminder When off hold for approximately 5 seconds The display will change from e...

Страница 15: ...f use Filters can be cleaned by hand with non abrasive soap or in a dishwasher Heavily soiled filters should also be soaked in grease cutting detergent prior to cleaning Metal Filter Clean Indicator W...

Страница 16: ...e from cooking They need not be replaced on a regular basis but are required to be kept clean After 30 hours of use the letter A will flash on the control screen indicating time to clean the metal mes...

Страница 17: ...ot hot Remove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup...

Страница 18: ...ctive part The unit is vibrating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation...

Страница 19: ...t Bulb GU 10 50W each Z0B 0020 Metal Mesh Filter each 50200011 Optional Accessories Recirculating Kit ZRC 0040 Replacement Charcoal Filter Z0F C002 Duct Cover Extension Z1C 00MI To order parts visit u...

Страница 20: ...ll labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABL...

Отзывы: