background image

8

www.zephyronline.com

Installation – 

Specifi

 cations

Top View

3/4 View

Back View

28-

3/8

”, 34-

3/8

12”

12”

3”

22-

3/8

”, 28-

3/8

19

-1/4

(28”)14-

1/4

(34“)17-

1/4

5-

5/8

1-

1/2

C/L

Ø 7-

3/4

  (28”)9-

1/4

  (34“)12-

1/4

2”

elec. 

 k/o 

10-

3/4

  (28”)  9-

1/4

  (34“)12-

1/4

9-

7/8

C/L

3-

1/4

5-

1/2

7-

3/4

Содержание ESSENTIALS Monsoon I AK9228AS290

Страница 1: ...stallation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer MAR12 0201 2012 Zephyr Ventilation Monsoon I AK9228AS AK9234AS AK9228AS290 AK9234AS290 READ AND SAVE THES...

Страница 2: ...www zephyronline com...

Страница 3: ...s 8 Electrical 9 Cabinet Preparation Installation 10 Vertical Ducting Preparation 11 Horizontal Ducting Preparation 12 14 FEATURES CONTROLS Touch Controls 15 16 RF Remote Control 17 MAINTENANCE Cleani...

Страница 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Страница 5: ...ircuit National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 This appliance requires a 120V 60Hz...

Страница 6: ...1 8 round adaptor w damper 1 3 1 4 x 10 rectangular adaptor w damper 2 Horizontal ducting blower mount brackets 1 Top rectangular cover plate 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SU...

Страница 7: ...Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15...

Страница 8: ...igher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and...

Страница 9: ...igid metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gr...

Страница 10: ...nstallation Specifi cations Top View 3 4 View Back View 28 3 8 34 3 8 12 12 3 22 3 8 28 3 8 19 1 4 28 14 1 4 34 17 1 4 5 5 8 1 1 2 C L 7 3 4 28 9 1 4 34 12 1 4 2 elec k o 10 3 4 28 9 1 4 34 12 1 4 9 7...

Страница 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere ci...

Страница 12: ...rews in the sides FIG 3 WARNING Make sure the surface you are securing the liner to is capable of holding the weight of AK92 Failure to do so may cause personal injury or damage to cooking surface or...

Страница 13: ...panels by removing 2 screws from behind each panel Installation Vertical Ducting Preparation 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 1 4 Remove bottom panel by 1 Removing 2 screws from left and...

Страница 14: ...ide spacer panels by removing 2 screws from behind each panel 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 1 4 Remove bottom panel by 1 Removing 2 screws from left and right sides of bottom panel 2 Pu...

Страница 15: ...inside the liner secure plate to top of liner with 2 3 16 x 3 8 screws A A B C C B 8 Remove knock outs A and B for rectangular ducting Remove knock outs B and C for round ducting Rect ducting Round du...

Страница 16: ...e Plug in blower molex plug Horizontal ducting preparation is now Horizontal ducting preparation is now complete Refer to Page 10 Step 5 to complete Refer to Page 10 Step 5 to complete installation co...

Страница 17: ...s levels selected 3 Delay Off This feature is used for programmed shut down of blower 5 minutes after the function is activated Press once a dot flashes in the lower right side of display indicating t...

Страница 18: ...se Reset the filter clean reminder timer after filters are cleaned and re installed With hood off press and hold for approximately 5 seconds until on display disappears The filter clean reminder funct...

Страница 19: ...sy storage The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder FIG 4 The remote holder can be inserted into a standard electrical outlet for easy storag...

Страница 20: ...dishwasher at low heat or soaked in hot soapy water Dry filters and re install before using hood Installing the Baffle Filters FIG 6 1 Place filter into top groove of the liner as shown and pull towa...

Страница 21: ...g bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the glass suction cup provided to the bulb...

Страница 22: ...d blower wheel 3 Change the blower The unit is whistling 1 A filter is not in the correct position 1 Adjust the filters until the whistling stops 2 The duct pipe connections are not sealed or connecte...

Страница 23: ...tlet Diameter 8in 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 625 650 675 700 725 750 Flow rate CFM THERMALLY PROTE...

Страница 24: ...5 0 50 0 55 0 60 0 65 0 70 Pressure inAq Blower Fan Curve Model AK92 290 Monsoon I AC Input 120V 60Hz Outlet Diameter 8in 0 00 0 05 0 10 0 15 0 20 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150...

Страница 25: ...5W each Z0B 0023 AK9228AS AK9234AS Baffle Filter Large each 50210013 AK9234AS Baffle Filter Small each 50210017 RF Remote Control 14000005 To order parts visit us online at http store zephyronline com...

Страница 26: ...all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIA...

Страница 27: ...ntretien et d installation www zephyronline com Num ro de mod le Num ro de s rie Date d achat D taillant MAR12 0201 Zephyr Corporation Monsoon I AK9228AS AK9234AS AK9228AS290 AK9234AS290 LISEZ ET CONS...

Страница 28: ...www zephyronline com...

Страница 29: ...lectricit 9 Pr paration et installation des armoires 10 Pr paration pour conduit vertical 11 Pr paration pour conduit horizontal 12 14 COMMANDES Commandes effleurement 15 16 Commande distance RF 17 EN...

Страница 30: ...ns surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R DUIRE LES RISQU...

Страница 31: ...cheminement du fil est ad quat N effectuez pas la mise la terre un tuyau de gaz Demandez un lectricien qualifi si vous n tes pas certain que la hotte a t mise la terre ad quatement N introduisez aucun...

Страница 32: ...Adaptateur rectangulaire de 3 1 4 x 10 avec registre 2 Supports de montage pour ventilateur avec conduit horizontal 1 Plaque sup rieure rectangulaire 1 Trousse de quincaillerie CONTENU DE LA TROUSSE D...

Страница 33: ...colonne 1 Pi ces de conduit Total Longueur x Nombre utilis 6 embout mural circ registre 30 pi x pi embout mural circ registre 30 pi x pi 7 or 10 circ coude 90 15 pi x pi 7 or 10 7 or 10 circ coude 45...

Страница 34: ...r 36 Il est important d installer la hotte la hauteur de montage ad quate Les hottes install es trop basses pourraient tre endommag es par la chaleur en plus de pr senter des risques d incendie plus l...

Страница 35: ...ez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban adh sif en toile ou du ruban r flecteur certifi Quelques options pour le conduit d a ration Installation Optio...

Страница 36: ...p cifi cations de la hotte Vue de haut Vue 3 4 Vue arri re 28 3 8 34 3 8 12 12 3 22 3 8 28 3 8 19 1 4 28 14 1 4 34 17 1 4 5 5 8 1 1 2 L C 7 3 4 28 9 1 4 34 12 1 4 2 Entr e d fon able 10 3 4 28 9 1 4 3...

Страница 37: ...en vigueur Alimentation lectrique Cet appareil requiert une alimentation lectrique de 120V 60 Hz Il doit tre connect un circuit terminal individuel d ment mis la terre prot g par un disjoncteur de cir...

Страница 38: ...nir le poids de la hotte AK92 sans quoi une personne pourrait se blesser ou la surface de cuisson ou le comptoir pourraient tre endommag s 5 Terminez l installation des composantes lectriques et du co...

Страница 39: ...rieur vers l avant du bo tier pour le lib rer des languettes de verrouillage 6 La pr paration pour l installation verticale du conduit est termin e Retournez l tape 4 de la page 10 pour terminer l in...

Страница 40: ...bo tier pour le lib rer des languettes de verrouillage 6 Enlevez le ventilateur du bo tier en retirant les 4 vis 3 16 x 3 8 de la partie sup rieure du bo tier Gardez les vis de c t pour une utilisati...

Страница 41: ...artir de l int rieur l aide des 2 vis 3 16 x 3 8 A A B C C B 8 Enlevez les entr es d fon ables A et B pour installer un conduit rectangulaire Enlevez les entr es d fon ables B et C pour installer un c...

Страница 42: ...hez le connecteur Molex La pr paration pour l installation La pr paration pour l installation verticale du conduit est termin e verticale du conduit est termin e Retournez l tape 5 de la page 10 Retou...

Страница 43: ...pour programmer l arr t automatique du ventilateur et des lumi res 5 minutes apr s son activation Lorsque vous appuyez une fois sur un point clignote dans la partie inf rieure droite de l afficheur p...

Страница 44: ...ur de nettoyage des filtres avec la hotte hors tension Lorsque la hotte est teinte appuyez environ 5 secondes sur la touche jusqu ce que l ic ne dis paraisse La fonction de rappel de nettoyage des fil...

Страница 45: ...o lectrique est munie d un aimant pour un entreposage facile La commande peut tre mise sur n importe quelle surface magn tique comme un r frig rateur ou le support commande Zephyr FIG 4 Le support com...

Страница 46: ...e l eau chaude savonneuse S chez les filtres et r installez les avant d utiliser la hotte Installation des filtres d flecteurs FIG 6 1 Placez le filtre vis vis de l entaille sup rieure comme illustr e...

Страница 47: ...contraire des aiguilles d une montre Note les ampoules ne se d vissent pas apr s une rotation de 60 degr s elles s arr tent et tombent de la douille Lorsqu il est difficile de retirer les ampoules ap...

Страница 48: ...ion de la hotte 3 L3 La roue du ventilateur est endommag e 3 Remplacez le ventilateur L appareil met un sifflement 1 L un des filtres est mal plac 1 Ajustez les filtres jusqu ce que le sifflement cess...

Страница 49: ...5 600 625 650 675 700 725 750 D bit pi3 min Prot g thermiquement Ventilateur 410W Lampe Max 35Wx2 Total Max 480W 3 9A Tension 120V 60Hz AK9234AS Consommation d nergie Mod le AK9228AS w p bu g y r br b...

Страница 50: ...0 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 Debit pi3 min Prot g thermiquement Ventilateur 82W Lampe Max 35Wx2 Total Max 152W 1 3A Tension 120V 60Hz AK9234AS290 Conso...

Страница 51: ...r pour AK9228AS AK9234AS grand chaque 50210013 Filtre d flecteur pour AK9234AS petit chaque 50210017 Commande distance RF 14000005 Pour commander des pi ces visitez nous en ligne au www zephyronline c...

Страница 52: ...main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PR SENTE GARANTIE...

Отзывы: