background image

17

www.zephyronline.com

W

arranty

TO OBTAIN SERVICE UNDER WARRANTY:
or any Service Related Questions, please call:
1-888-880-8368

Staple your receipt here.

Proof of the original purchase

date is needed to obtain service

under the warranty.

TO OBTAIN SERVICE UNDER WARRANTY: 

You must present proof of original purchase date.

Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.

One Year Service Repair Warranty:

For one year from date of original purchase, we will provide free of charge, service labor to repair any failed

parts or components due to manufacturing defects.

One Year Parts Warranty:

For one year from date of original purchase, we will provide free of charge, nonconsumable replacement

parts or components that failed due to manufacturing defects. Consumable parts not covered by this

warranty include: Light Bulbs, Metal and Carbon Filters.

Who is Covered:

This warranty is extended to the original purchaser for products purchased for ordinary home use in the 48

mainland states, Hawaii and Washington D.C. In Canada and Alaska, this warranty is Limited. There might

be costs associated with shipping the products to our designated service locations or you might need to

pay service technician’s travel costs, to have the appliance repaired in-home.

This Warranty will be Voided when:

Product  damaged  through  negligence,  misuse,  abuse,  accident.  Improper  installation  and  failure  to  follow

installation  instructions.

When product is used commercially or other than its intended purpose. Damaged because of improper

connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr’s

Authorized Agents.

What is Not Covered:

Consumable parts such as light bulbs, filters, and fuses. Services outside of service area and the labor

cost incurred in connection with the removal, shipping and reinstallation cost, nor does it cover any other

contingent expenses. The natural wear of finish, and wear due to improper maintenance, use of corrosive

and abrasive cleaning products, pads, and oven cleaner products. Chips, dents or cracks due to abuse,

misuse, freight damage, or improper installation. Service trips to your home to teach you how to use the

product. Damage of product caused by accident, fire, floods or act of God.

This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original

purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties,

including the warranty of merchantantability, are limited in duration to a period of express warranty as

provided herein beginning with the date of original purchase at retail and, no warranties, whether express

or implied, shall apply to this product thereafter.

Have your product proof of purchase with date ready for warranty issues.

Or write to:

Zephyr Corporation
Service and Warranty Department
395 Mendell Street
San Francisco, CA 94124

Содержание elica EAT-E36ASX

Страница 1: ...JAN06 0101 ...

Страница 2: ...leave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this appliance Requirement 120 V AC 60 Hz 15 or 20 A Branch Circuit E page 2 F page 21 S page 41 APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS ...

Страница 3: ...s not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Description of the hood Controls 14 Controls 14 Description of control panel 14 Maintenance 15 Cleaning 15 Grease filter 15 Replacing the light bulb 15 Trouble Shooting 16 Warranty 17 List of Parts and Accessorie...

Страница 4: ...se This Hood With Any External Solid State Speed Control Device WARNING TOREDUCETHERISKOFARANGETOPGREASEFIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe ...

Страница 5: ... local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 BEFORE INSTALLING THE HO...

Страница 6: ...x 1 Lower support bracket Template Use Care and Installation guide PARTS NOT SUPPLIED Duct conduit and all tools required for installation Ductless Recirculating Kit to be used only in the Ductless recirculating version includes charcoal filter charcoal filter support and fixing bracket deflector Internal blower To be used only in case of Internal blower installation In line blower To be used only...

Страница 7: ... 24 to 32 bottom of canopy to cooking surface ceiling CenterLine 12 21 min 12 10 1 2 Ducting and conduit area passage Duct bends are not considered 26 12 16 max 44 2 16 min 27 9 16 20 8 16 11 12 16 13 6 16 max 48 7 16 min 33 7 16 Ductless recirculating version ONLY Note if necessary order the proper duct cover extension kit ...

Страница 8: ...ion 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fittings material is provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitability of the materials in accordance with the type of wall ceiling The weight of the hood is Before making cuto...

Страница 9: ...d wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Round roof cap 7 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 30 Ft x 30 Ft x 1 Ft x 16 Ft x 15 Ft x 9 Ft x 30 Ft x 30 Ft x 8 Ft x 15 Ft x Ft Ft Ft Ft Ft Ft Ft Ft F...

Страница 10: ...n must span the studs otherwise proceed as follows Cutout drywall along marked lines Install each necessary between studs firmly flush with already existing stud front Make sure all mounting screws will anchor to added studs Replace drywall and refinish 9 Determine and make all necessary cuts in the wall for the vent system Install the vent system before the canopy hood See Venting methods and Dim...

Страница 11: ...the lower part of the hood with the internal blower housing a Remove the grease filter see also Care Use section Charcoal filter b Rest the internal blower housing on a flat surface and thread completely the lower part of the hood onto it REAR VIEW c Connect all cables d Fasten the hood to the motor unit using 8 screws 6 screws from the top TOP VIEW REAR SIDE FRONT SIDE 2 screws from the bottom BO...

Страница 12: ...ection WARNING Electrical Shock Hazard Warning Turn off power circuit at the service panel before wiring this unit 120 VAC 15 or 20 Amp circuit required ELECTRICAL GROUNDING INSTRUCTIONS THISAPPLIANCE IS FITTED WITHAN ELECTRICAL JUNCTION BOX WITH 3 WIRES ONE OF WHICH GREEN YELLOW SERVES TO GROUND THE APPLIANCE TO PROTECT YOUAGAINST ELECTRIC SHOCK THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE ...

Страница 13: ...ulating installations Install one charcoal filter available as an extra kit 23 Check all light bulbs to make sure they are secure in their sockets Turn power on in service panel Check lights and blower operation 24 Install filters 25 Install duct cover with 4 screws Note Upper Duct Cover may be placed upside down to hide or unhide ventless slots Upper duct cover Lower duct cover Duct cover support...

Страница 14: ...d kitchen vapours It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking Note Hood retains last speed setting when aspiration switch is turned off Description of control panel A on off light switch B on off aspiration switch and minimum power selection B...

Страница 15: ...nd or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but this does not affect its filtering capacity To remove the grease filter pull the spring release handle a b REPLACING THE LIGHT BULB WARNING Disconnect the hood from electricity and be sure the lights are cool If new lights do not operate make s...

Страница 16: ...ng area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loose Issue Cause What to do 1 Make sure the circuit breaker and the unit s power is ON 2 Check the power connection with the unit is connected properly 3 Make sure the wirings between the switch board a...

Страница 17: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connection with equipment of other manufacturers Repaired or modified by anyone other than Zephyr s Authorized Agents What is Not Covered Consumable parts such as light bulbs filters and fuses Services outsi...

Страница 18: ...ion Part Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm ZRC 00AT EBI 600A EBN 1100A Z1C 00AT Z0F C060 Part Description Part halogen bulb 12V 20 W metal filter Z0B 0013 ...

Страница 19: ...19 www zephyronline com ...

Страница 20: ...20 ...

Отзывы: