PARTS SUPPLIED:

• Blower  unit  housing

• Hood canopy

• Metal filter x 1

• Halogen light bulb x 4

• Upper and lower Duct covers x 4

• Chimney structure

• Hardware Packet:

Allen spanner x 1

Template

Use,  Care  and  Installation  guide

Nuts x 12

3,5x6,5 screws x 15 (11 to assemble Hood canopy to Chimney str 4 to fix duct covers to chimney structure

and to hood canopy )

4 x 6 screws x 12 (to assemble duct covers)

7x45 screws x 6

3,5x9,5 screws x 24  (to assemble chimney structure)

PARTS NOT SUPPLIED

• Duct, conduit and all tools required for installation.

•

Ductless Recirculating Kit

to be used only in the 

Ductless (recirculating) version

includes:

 charcoal filter, charcoal filter support and fixing bracket, deflector

•

Internal blower

To be used only in case of Internal blower installation.

•

In-line blower

To be used only in case of in-line blower installation

•

Noise reduction sponge

Note: may be already included on internal/in-line blower package.

CAUTION

To reduce the risk of fire and electric shock, install this rangehood only with integral blowers mod. EBI-600 rated 120V

60Hz 450W or with remote blowers mod. EBN-1100 rated 120V 60Hz 900W, manufactured by Elica.

Содержание EAL-E42ASX

Страница 1: ...JAN06 0101...

Страница 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Страница 3: ...sions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Description of the hood Controls 1...

Страница 4: ...his Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and gr...

Страница 5: ...local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may...

Страница 6: ...e PARTS NOT SUPPLIED Duct conduit and all tools required for installation Ductless Recirculating Kit to be used only in the Ductless recirculating version includes charcoal filter charcoal filter supp...

Страница 7: ...ronline com Dimensions and clearances 14 12 3 16 42 48 26 12 16 27 7 16 1 2 16 min 32 6 16 min 31 7 16 max 48 7 16 Ductless recirculating version ONLY Note if necessary order the proper duct cover ext...

Страница 8: ...um Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fitting...

Страница 9: ...und wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 round 90 elbow 7 round 45 elbow 6 Round wall cap with damper 6 Round ro...

Страница 10: ...rked on ceiling to position the mounting template Note location of hood front that indicated with a printed arrow side and mounting holes indicated on template Note Remember that printed arrow on temp...

Страница 11: ...6 7 8 FRONT 4 For non vented recirculating installations ONLY Fix the deflector on the chimney structure 5 Note disregard this step if is intended to install a remote ventilator Purchase and install...

Страница 12: ...ite and green according to the National Electrical Code and local codes and ordinances in 1 2 conduit from service panel to junction box J Box cover Conduit Connect black wire from service panel to bl...

Страница 13: ...s squere slots and fix each other with 6 screws 3 per side Rectangular slots Plan diagram top sections Nut top sections Chimney Structure 13 Install top duct covers assembly to the chimney structure F...

Страница 14: ...top view rear bottom duct covers section snap into place 15 Fit the front bottom duct covers section and fix both sections with 8 screws each other the lower screws fix duct cover to canopy front bot...

Страница 15: ...e in their sockets Turn power on in service panel Check lights and blower operation per Care Use section of this manual If range hood does not operate Check that the circuit breaker is not tripped or...

Страница 16: ...cases of concentrated kitchen vapours It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes a...

Страница 17: ...d or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but this does not affect its filtering capacity T...

Страница 18: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Страница 19: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connect...

Страница 20: ...on Part halogen bulb 12V 20 W metal filter Part Description Part Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm ZRC 00A...

Страница 21: ...21 www zephyronline com...

Страница 22: ...22...

Отзывы: