10
Inst
allation
1. Pre-installation calculations
2"
K
C
(36" std)
P
S
H
a)
Select a hood preference height
P
that is
comfortable for the user. (from 24 to 32).
b)
Calculate Hood height your installation H = K-C-P.
c)
Confirm that H is within the range of min to max H
found for your model (see Dimensions and
clearances paragraph). If not adjust your
installation.
d)
Calculate Chimney structure height S. Save this
calculation for use later in the installation.
2. Preparation of mounting surface
Installing supports above ceiling drywall.
Ceiling
Template
Note: Take into consideration the hood depth; the
hood could be much deeper than the cooktop.
a.
Mark center lines of cooktop or range on ceiling
above. Use centerlines marked on ceiling to position
the mounting template.
Note location of hood front (that indicated with a
printed arrow), side, and mounting holes indicated
on template.
Note:
Remember that printed arrow on template
corresponds to front of the hood and consequently to
side where control panels will be located at the end
of installation)
b.
Remove and save template. Cut and remove ceiling
drywall. Install suitable length 2" x 4" lumber
between joists to provide chimney mounting points
as shown above. Use template for dimensions and
required clearance.
Make sure to affix the added lumber firmly and level.
Consult a professional if you have difficulties or your
installation is unique. Consult template and
Figs.above.
K
= Kitchen Height
C
= Counter Height (36"
standard)
P
= Prefered Height of Hood
Bottom above counter
(recommended 24-32)
H
= Hood height your
installation
H
= K C P
S
= Chimney Structure
Height, your installation.
S
= H 2"