Страница 1: ...ne com 0 1 lmmm Cypress AK7836ASX AK7842ASX AK7848ASX INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA C Model number Serial Number Date of Purchase Sales Dealer AUG08 0101 Zephyr Corporation READ AND...

Страница 2: ...www ze vio lie __ _ v 7 _i...

Страница 3: ...ce 6 Ducting Options 7 Specifications 8 Electrical 9 Mounting the Range Hood 10 Single and Dual Internal Blowers 11 Remote Blower Preparation 12 1 C O 13 O m _13 FEATURES CONTROLS Touch Controls 13 MA...

Страница 4: ...mount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS iN THE EVENT OFA RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray...

Страница 5: ...1 and C22 2 No 0 M91 latest edition and aalIocaacodes and ordinances if codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path i...

Страница 6: ...package HARDWARE PACKAGE CONTENTS Suction Cup 1 M4 x 2 4 M4 x 1 1 2 4 M4xl 4 ________ M4 x 8 4 GGG M4 x 16 4 Wire Caps 3 PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector...

Страница 7: ...x 90 oelbow 6 Round 9 Ft x 45 oelbow Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Subtotal column 1 Ft Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet...

Страница 8: ...umber or transitions and turns If long duct run is required increase duct size If turns or transitions are required install as far away from hood duct output and as far apart between the two as possib...

Страница 9: ...xhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Roof Pitch...

Страница 10: ...1 8 9 16 I 2 5 16 9 16 I 6 7 16 13 3 16 I I i I I I i I I CL 2 1 16 f 2 _ 2 11 16 ext elec blwr k o k o 4 I 12 10 4 5 16 18 27 10 transition used with dual external and in line blowers top side 35 15...

Страница 11: ...a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please al...

Страница 12: ...x H AK7836ASX 34 x 3 4 x 4 AK7842ASX 40 x 3 4 x 4 AK7848ASX 46 x 3 4 x 4 5 Hang hood on wood board and secure using 4 M4 x 16 screws NOTE Due to the weight of this hood ensure that the wood strip is a...

Страница 13: ...crews blower pictured is a PBI 1100A Connect male end of blower wire to female plug in the hood plug is located inside the hood behind the control panel 3 Single Blower Connect 6 round duct work to bl...

Страница 14: ...4 wiring and secure by turning clockwise REMOTE BLOWER WIRING DIAGRAM Connect 6 pin male connector from external blower wiring to 6 pin female connector on control board wire inside hood Secure green...

Страница 15: ...By pressing _ the light is switched On and Off I is on O is off Blower Speed Selection The 2 speed levels are selected by switching to for level one and Switching the rocker switch to middle O will t...

Страница 16: ...ers are intended to trap residue and grease from cooking Although the filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filter...

Страница 17: ...bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diamet...

Страница 18: ...ten the motor in place vibrating 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is 1 Defective halogen bulb 1 Change the h...

Страница 19: ...lower In Line Blower Vinyl Cover 36 Vinyl Cover 42 Vinyl Cover 48 12 Duct Cover 36 12 Duct Cover 42 12 Duct Cover 48 PART ZOB 0023 50210009 CBI 600B PBI 1100A CBE 1000 PBN 1000A AK0636AB AK0642AB AK06...