background image

9

www.zephyronline.com

Ducting Options and Examples

Closely follow the instructions set out in this manual.

All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in
this manual, is declined.

VENTING METHODS

This range hood is designed to exhaust fumes and vapours towards the outside and is ready to be fitted with an internal
blower and for discharge towards the top side (Vertical discharge).
This range hood can be set for an External Blower and /or to discharge towards the rear side (Horizontal discharge).
Before installation choose type of motor an discharge direction.
Consult paragraph "Dimensions and Clearances" and "Installation  - Ductwork Calculation Sheet" for further
informations.

Minimum Duct Size : 8" Round Pipe or 3 1/4 ” x 10” Rect. Pipe

 (Rect. Pipe can be used for Internal blower installation

only)

PREPARATION

Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be
constructed.

Fitting material is provided to secure the hood to most types of walls/ceilings.
However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

Hood installation height above cooktop is the users preference.  The lower the hood is above the cooktop, the more
efficient the capturing of cooking odors, grease and smoke.

The hood shall be installed at 28" minimum above the countertop (Distance must be taken from the bottom side of
the hanging rail of the front panel).

Check your ceiling height and the hood height maximum before you select your hood.

Refer to the following table for the weights

:

DESCRIPTION

MODEL

HOOD ONLY

INTERNAL BLOWER

42"

98.5 lbs.

48"

54"

9.5 lbs.

105 lbs.

9.5 lbs.

112 lbs.

9.5 lbs.

Содержание Cheng Padova CPA-E48ASX

Страница 1: ...Date d achat _____________________________________ Fecha de compra Sales Dealer D taillant _____________________________________ Distribuidor LI2ZRA DEC06 0101 READ AND SAVE THESE INSTRUCTIONS Guide...

Страница 2: ...e Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this app...

Страница 3: ...methods 9 Preparation 9 Installation Ductwork Calculation Sheet 10 Installation Preliminary Operations 11 Installation Internal Blower 12 13 Top discharge Vertical discharge 12 Rear discharge Horizont...

Страница 4: ...al connection 20 Description of the Hood 21 Features Controls Touch Controls Features 22 Description of control panel 22 Features Controls Baffle Filters Change Indicator 23 Maintenance 24 25 Cleaning...

Страница 5: ...k Do Not Use This Hood With Any External Solid State Speed Control Device WARNING TOREDUCETHERISKOFARANGETOPGREASEFIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Страница 6: ...S A listed conduit connector must be provided at each end of the power supply conduit At the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protec...

Страница 7: ...und transition 1 piece Rectangular transition air discharge flange External blower wiring box with wires Template 1 piece Use Care and Installation Guide Warranty PARTS NOT SUPPLIED Duct conduit and a...

Страница 8: ...ection for the passage of the discharge pipe for connection to the external motor Consult the template for the passage of pipes under this measurement Hood with external motor Above this measurement a...

Страница 9: ...Internal blower installation only PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fitting material is pro...

Страница 10: ...cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Round roof cap 7 Round to 3 1 4 x 10 r...

Страница 11: ...ws We recommend to record and keep all of these components in a safe place ready to be used as required Remove stainless mesh filters See relative paragraph on Maintenance section of this manual Relea...

Страница 12: ...ng the 4 fixing screws From the inside of the hood rear side remove cover rectangular transition support from the range hood body unscrewing the 4 fixing screws Install the motor support to the body o...

Страница 13: ...blower to the support with 4 screws Provided check that the rectangular outlet of the blower matches with the rectangular slot of the support Note The 4 fixing screws must be screwed in from the outsi...

Страница 14: ...ternal Blower Preparation Note for internal blower installation disregard the instruction on this next page and consult the instruction on the previous pages See pages 12 13 Note 2 Refer to the CBE 10...

Страница 15: ...er junction box See diagram below Installation External Blower Preparation EXT BLOWER REMOTE FAN UNIT JUNCTION BOX BLACK HIGH RED LOW WHITE COMMON BLUE MED Y G GROUND HOOD CONNECTION WIRE TO WIRE BLAC...

Страница 16: ...tuds through the front bodies corresponding holes Use 8 wing nuts to attach and secure See diagrams below 2 3 1 4 6 5 8 7 1 2 3 4 5 6 7 8 3 4 Installation Front Panel NOTE The front panel is not suppl...

Страница 17: ...as follows Cutout drywall along marked lines Install wood blocking between studs and make sure it is flush with existing stud front Make sure all mounting screws will anchor to added studs Replace dry...

Страница 18: ...ence Position reference CenterLine Duct cover support barcket Installation Installing the Duct Covers Unscrew the 4 screws that fix the section of the Duct Cover Starting collar and release all parts...

Страница 19: ...lower bracket WARNING Excessive Weight Hazard Use three or more people to move and install range hood Failure to do so can result in back or other injury 16 Secure hood with screws and washers 17 Con...

Страница 20: ...and local codes and ordinances in 1 2 conduit from service panel to junction box J Box cover Conduit Connect black wire from service panel to black or red in junction box white to white and green to...

Страница 21: ...21 www zephyronline com Description of the Hood 1 Controls 2 Baffle filter 3 Halogen lamp 4 Incandescent ambient lamp 5 Hood body 6 Duct cover 6 2 2 3 3 4 1 5...

Страница 22: ...ase speed level The display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated Press once a dot flashes in the l...

Страница 23: ...an be cleaned by hand with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hou...

Страница 24: ...l retaining clip together the light socket will now protude from the hood allowing you to remove the bulb Be careful when releasing retain clip as it is under pressure to hold it in place Replacement...

Страница 25: ...HTING BULB To replace mood lighting bulb remove baffle filter from hood To access lamp area remove the two threaded knobs that fix the cover Unscrew mood lighting bulb counter clockwise and replace wi...

Страница 26: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Страница 27: ...CPC 0112 Front Panel 48 SS CPC 0018 Front Panel 48 Brass CPC 0118 Front Panel 54 SS CPC 0015 Front Panel 54 Brass CPC 0115 50210002 Doluflex 6pc Blank 42 CDO 0042 Doluflex 6pc Blank 48 CDO 0048 Doluf...

Отзывы: