through the fl ue (chimney) of fuel burning equipment to prevent back drafting. 
Follow the heating equipment manufacturer’s guideline and safety standards 
such as those published by the National Fire Protection Association (NFPA), and 
the American Society for Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.

C.

 When cutting or drilling into wall or ceiling, do not damage electrical wiring 

and other hidden utilities.

D. 

Ducted fans must always be vented to the outdoors. 

E.

 This unit must be grounded.

 

WARNING

  - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

 

 

 WARNING

 - UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES    MAY 

BE DANGEROUS.

A. 

Do not check fi lters with hood working.

B.

 Do not touch the lamps after a prolonged use of the appliance.

C.

 No food must be cooked fl ambè underneath the hood.

D.

 The use of an unprotected fl ame is dangerous for the fi lters and could  cause 

fi res.

E.

 Watch constantly the fried food in order to avoid the cooking oil fl ares up.

F.

 before performing any mainteinance operation, disconnect the hood from 

the electrical service.

 The manufacturers will not to accept any responsability for eventual damages, 

because of failure to observe the above instructions. 

S

a

fe

ty instruc

tions

- 6 - 

Содержание ASL-E42ASX

Страница 1: ...www zephyronline com Surface Is ASL E42ASX ASL E48ASX RANGE HOOD Installation instructions...

Страница 2: ...www zephyronline com HOTTE PER CUISINE Notice d utilisation Pag 23 CAMPANA EXTRACTORA Manual de utilizaci n Pag 45 CAPPA ASPIRANTE istruzioni per l uso Pag 67 2...

Страница 3: ...LCULATION SHEETS pag 8 HOOD SPECIFICATION pag 9 INSTALLATION INTERNAL BLOWER pag 10 EXTERNAL IN LINE BLOWER PREPARATION pag 12 DUCTING OPTIONS pag 14 MOUNTING THE RANGE HOOD pag 15 POWER SUPPLY CONNEC...

Страница 4: ...to exhaust hazardous or explosive materials and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Plea...

Страница 5: ...AREFUL TO PREVENT BURNS If the flames do not go out mmediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towe...

Страница 6: ...This unit must be grounded WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DANGEROUS A Do not check filters with hood working...

Страница 7: ...ls Decorative Mesh Filters Control Blower Housing Light Bulbs Range Hood Body Duct Covers Support Frame Assembly TYPE DESCRIPTION N A M4 1 1 B 1 8 x 1 4 28 C 1 4 x 2 3 4 4 D M4 x 9 16 4 Duct Cover Cei...

Страница 8: ...www zephyronline com Ducting Calculation Sheet Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 8...

Страница 9: ...Hood Specifi cations front of hood side of hood top of hood 9...

Страница 10: ...port bracket to the motor housing and then remove the bracket See Fig 1 2 Insert the 6 sheet metal flange in the motor air exhaust outlet Fig 2A Then insert the plate supplied with the motor and secur...

Страница 11: ...e motor and bracket inside the motor housing completing the installation using the other screws 6 type B that have been sup plied Tot 13 type B Fig 7 8 Connect 9 pin male molex connector from blower w...

Страница 12: ...cut circle in the lid located on the remote motor sup port bracket using a flat head screwdriver Fig 1 2 Remove the cover by un doing the 3 screws Fig 2 3 Secure 8 round blower col lar to top of blow...

Страница 13: ...6 Reinstall the cover on the motor housing by following the instructions from step 2 in re verse order 7 Attach 6 pin male molex connectors to 6 pin female molex connectors inside blower hou sing See...

Страница 14: ...spaces ceiling attics or garages All exhaust must be ducted to the outside unless using the recirculating op tion Use single wall rigid Metal ductwork only Fasten all connections with sheet metal scr...

Страница 15: ...e decorative mesh filters so that the range hood is easier to handle MOUNTING TO THE CEILING The following instructions assume the installer has access to the attic or crawl space Each installation ma...

Страница 16: ...4 holes in the ceiling and drive in 3 type C screws without completely tightening them Pay attention not to in sert the screw into the hole marked with an X on the hole template Fig 11 4 Lift the hood...

Страница 17: ...Fig 13 6 Insert the motor housing into the support frame assembly and secure it using 8 type B screws Fig 14 7 Connect the equipment to the power supply by following the steps shown in the section POW...

Страница 18: ...n closure using a flat head screwdriver Fig 15 9 Remove the power supply cover by un doing the 2 screws Fig 16 10 Connect the supply conduit to the cover then connect the hood to the power sup ply by...

Страница 19: ...e ducting for your installation not supplied to the collar on top of the housing Fig 18 14 Extend upper duct cover to the ceiling and secure it to the duct cover ceiling bra cket using the 4 screws pr...

Страница 20: ...vent a fire hazard it is recommended to clean the filter a minimum of every 2 months or when instructed by the Metal Filter Clean indicator on the range hood controls Clean the range hood by carrying...

Страница 21: ...Light Bulb GU4 20W each ASL Z0B0030 OPTIONAL ACCESSORIES Recirculating Kit ASL ZRC 00SL Replacement Charcoal Filters ASL Z0F 00AC Duct Cover Extension 12 ceiling ASL Z1C 00SL To order parts visit us...

Страница 22: ...www zephyronline com 22...

Страница 23: ...3LIK0510...

Отзывы: