www.zephyronline.com
Installa
tion - In
ternal Blo
w
e
r
The following instructions are for installing the internal blower.
CAUTION: To reduce the risk of fi re and electric shock, install this range-
hood only with internal blower models MT-020 provided with the kit cod
CBI-600A.
For external and in-line blower preparation
please turn to page 14.
1. Remove the (7) screws securing the remote
motor support bracket to the motor housing
and then remove the bracket. See Fig.1
2. Insert the 6” sheet metal fl ange in
the motor air exhaust outlet. Fig.
2A Then insert the plate (supplied
with the motor) and secure all
parts using the (4) screws. Fig2B
3. Secure the condenser, connected
to the supplied wire, to the bracket
using the (2 type B) screws. See
Fig.3
4. Secure the green/yellow ground
wire, connected to the wire supplied
with the condenser, using the screw on the bra-
cket. (type A) Fig. 4
5. Connect the plate and the motor, on the
remote motor support bracket, securing it
using the (2 type B) screws. Fig. 5
- 12 -