the heater does not switch on, the safety device has been activated.
-
Remove the mains plug from the wall socket.
-
Let the heater cool down for 30 minutes.
-
Check if the heater had been placed correctly.
-
Check if anything is obstructing the air flow.
-
If necessary, clean the grilles with a vacuum cleaner.
-
Replace the plug into the wall socket and switch the heater on again.
If the safety device again switches off the heater:
-
Have the heater inspected by a Service Centre or by your dealer.
.
CLEANING AND MANTEINANCE
We recommend that you clean your heater at least twice a year to remove accumulated dust and dirt.
-
Set the selector switch to position ( ) to switch off. Remove the mains plug from the wall socket. Wait for the heater
to cool down sufficiently.
-
You may clean the outside of the heater with a damp cloth or brush. Do not use water or allow water to come
into the appliance. Do not use any abrasive and caustic cleaning agents!
-
Never touch the heater in water! Danger to life!
-
Clean the air inlet and outlet grilles regularly with a vacuum cleaner, using the brush attachment.
-
Pack the heater in the original box and store it in a cool, dry place.
INFORMATION REQUIREMENTS FOR LOCAL SPACE HEATERS
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output
P
nom
2,0
KW
manual heat charge control, with integrated thermostat
N/A
Minimum heat
output (indicative)
P
min
1,0
KW
manual heat charge control with room and/or outdoor
temperature feedback
N/A
Maximum
continuous heat
output
P
max,c
2,0
KW
electronic heat charge control with room and/or outdoor
temperature feedback
N/A
Auxiliary electricity consumption
fan assisted heat output
N/A
At nominal heat
output
el
max
0
KW
Type of heat output/room temperature control (select one)
At minimum heat
output
el
min
0
KW
single stage heat output and no room temperature control
no
In standby mode
el
SB
0
KW
Two or more manual stages, no room temperature control
no
with mechanic thermostat room temperature control
sì
with electronic room temperature control
no
electronic room temperature control plus day timer
no
electronic room temperature control plus week timer
no
Other control options (multiple selections possible)
room temperature control, with presence detection
no
room temperature control, with open window detection
no
with distance control option
no
with adaptive start control
no
with working time limitation
no
with black bulb sensor
no
Contact details info
Westim S.p.A Via Roberto Bracco 42/E