DATASHEET / OPERATING INSTRUCTIONS

 

 

 
 
 
 

POWER SUPPLIES AND BATTERY CHARGERS, TRIMMER ADJUSTABLE

 

Type

 

Input voltage range 

 

**)

 

Nominal 
output 
voltage

 

Voltage 
setting 
range

 

Nominal 
output 
current

 

Current 
setting 
range

 

Max 
power

 

Installation / dimensions 

(Width x Height x Depth, mm)

 

ZAT1600/24/60/_/ 

55-264VAC/78-340VDC

 

24 VDC

 

0-36 VDC

 

60 A

 

0-60 A

 

1600W

 

Wall//Bench 267x135x85

 

ZAT1600/36/45/_/

 

55-264VAC/78-340VDC

 

36 VDC

 

0-54 VDC

 

40 A

 

0-40 A

 

1600W

 

Wall//Bench 267x135x85

 

ZAT1600/48/30/_/

 

55-264VAC/78-340VDC

 

48 VDC

 

0-72 VDC

 

30 A

 

0-30 A

 

1600W

 

Wall//Bench 267x135x85

 

 

ANALOG CONTROLLABLE MODELS BY EXTERNAL 0-5VDC VOLTAGE

 

Type 

 

*)

 

Input voltage range 

 

**)

 

Nominal 
output 
voltage

 

Voltage 
setting 
range

 

Nominal 
output 
current

 

Current 
setting 
Range

 

Max 
power

 

Installation / 

dimensions 

(Width x Height x Depth, mm)

 

ZAT1600/24/60/AI/ 

55-264VAC/78-340VDC

 

24 VDC

 

0-36 VDC

 

60 A

 

0-60 A

 

1600W

 

Wall//Bench 267x135x85

 

ZAT1600/36/45/AI/

 

55-264VAC/78-340VDC

 

36 VDC

 

0-54 VDC

 

40 A

 

0-40 A

 

1600W

 

Wall//Bench 267x135x85

 

ZAT1600/48/30/AI/

 

55-264VAC/78-340VDC

 

48 VDC

 

0-72 VDC

 

30 A

 

0-30 A

 

1600W

 

Wall//Bench 267x135x85

 

 

BATTERY CHARGERS WITH TEMPERATURE COMPENSATION

 

Type 

 

*)

 

Input voltage range 

 

**)

 

Output 
voltage 
factory setting

 

Programmed 
output voltages 

(see  table)

 

Output 
current 

(see  table)

 

Max 
power

 

Installation / 

dimensions 

(Width x Height x Depth, mm)

 

ZAT1600/27,4/60/T/ 

55-264VAC/78-340VDC

 

27.4 VDC

 

5…36VDC

 

60 A

 

1600W

 

Wall//Bench 267x135x85

 

ZAT1600/41,1/45/T/

 

55-264VAC/78-340VDC

 

41.1 VDC

 

12…54VDC

 

40 A

 

1600W

 

Wall//Bench 267x135x85

 

ZAT1600/54,8/30/T/

 

55-264VAC/78-340VDC

 

54.8 VDC

 

24…72VDC

 

30 A

 

1600W

 

Wall//Bench 267x135x85

 

*)    Cable sets with modular connectors are included in packing: 1.5m cable set for analog control and 2.5m for or temp.comp models 
**)  Reduced power 55…200VAC or 78…200VDC, see curves at next page 

 

MODELS WITH POWER FAIL RELAY ALARM (24V models as a type number example)

 

Type

 

Option description

 

Cable set

 

ZAT1600/24/60/H 

Trimmer adjustable model with power fail relay alarm

 

1.5 m, modular connector

 

ZAT1600/24/60/AIH

 

Analog controllable model with power fail relay alarm

 

Analog 1.5m + relay cables 1.5m

 

ZAT1600/24/60/TH

 

Temp.comp model with  Power fail relay alarm

 

Temp.comp 2.5m + relay cables 1.5m

 

 

MASTER-SLAVE CONNECTION (24V models as a type number example)

 

Master units ***)

 

Slave units

 

ZAT1600/24/60 or ZAT1600/24/60 AI or ZAT1600/27,4/60 T 
Control to slave via RS-232 bus

 

ZAT1600/24/60 S RS-232 control bus in and out

 

ZAT1600/24/60 SH  slave unit with relay, RS-232 bus in only

 

Cable set for master slave connection is included in slave unit type number, length 0.6m modular connectors in both ends

 

***) Master unit or slave with RS-232 bus output can not include the relay alarm 

 

CUSTOMISED VERSIONS ON

 

 

• 

Cyclic battery chargers or customzed charging curves for all kind of batteries 

• 

Sense models 

• 

Customised mechanics 

 
 
 
 
 
 
 
 

 

 

 
 
 

 

Содержание ZAT1600 SERIES

Страница 1: ...600W Power Supplies and Battery Chargers ZAT1600 SERIES TASHEET OPERATING INSTRUCTIONS Wide output adjustment range 0 72VDC Analog control by external 0 5VDC voltage Temp comp charging sense as on option Power fail relay alarm Master Slave connection Analog control modular connector Microprocessor controlled charging curves for all kind of batteries Master Slave connection ...

Страница 2: ... see table Output current see table Max power Installation dimensions Width x Height x Depth mm ZAT1600 27 4 60 T 55 264VAC 78 340VDC 27 4 VDC 5 36VDC 60 A 1600W Wall Bench 267x135x85 ZAT1600 41 1 45 T 55 264VAC 78 340VDC 41 1 VDC 12 54VDC 40 A 1600W Wall Bench 267x135x85 ZAT1600 54 8 30 T 55 264VAC 78 340VDC 54 8 VDC 24 72VDC 30 A 1600W Wall Bench 267x135x85 Cable sets with modular connectors are...

Страница 3: ...sions l x w x h 267 x 135 x 85 mm with rubber ends Weight 1 9kg without output cables Mounting Wall bench Cooling Temperature controlled fan Operating temperature range Full power typically 25ºC 40ºC Reduced power 40 70ºC see curve below Humidity 0 95 non condensing DATASHEET OPERATING INSTRUCTIONS TECHNICAL DATA Input voltage 50 260 VAC 50 200VAC reduced power see curve below 50 340 VDC 50 200VDC...

Страница 4: ...nstant orange light To avoid sparking turn the power off before disconnecting the cables CONNECTION WITH DC INPUT Wires in PSU s power cable to be connected as follows L DC input positive or negative N DC input negative or positive PE Ground OUTPUT VOLTAGE AND CURRENT LIMIT ADJUSTMENT Trimmer or analog control adjustable modules type example ZAT1600 24 60 or ZAT1600 24 60 AI The output voltage and...

Страница 5: ... code Switch N N PIN CONFIGURATION MODULAR CONNECTORS Front panel Rear panel J1 Analog input 0 5VDC J3 Temperature compensation Sense option J5 RS 232 bus in and out master slave Alternatively power fail relay alarm OPTIONAL ALARM RELAY If the unit is ordered with alarm relay for example ZAT1600 24 60 H the potential free alarm output indicates if the charger s output is healthy The alarm signal i...

Страница 6: ...output terminals That allows serial and parallel connection to separate power supply s so that equal steering voltages are used Number or connected devices are not limited Only be sure that 500V insulation voltage is not exceeded Connection example using internal 5VDC power source and external potentiometers 5V output can be used to feed logic voltages for external circuits Connection in an exampl...

Страница 7: ...le If more current is needed adjustable Master power supply can be parallel or series connected via digital bus to Slave power supply which equals Master but is without adjustment possibility Then output current or voltage is doubled and the both supplies can still be adjusted thought multi turn potentiometers Max one slave unit can be used in master slave connection as a standard Please contact y...

Страница 8: ...rrent 5 5 0 12 VDC 11 4 VDC 12 6 VDC 45 A 1 12 VDC 13 7 VDC 13 VDC 14 39 VDC 45 A 2 15 VDC 14 3 VDC 15 75 VDC 45 A 3 20 VDC 19 VDC 21 VDC 45 A 4 24 VDC 22 8 VDC 25 2 VDC 45 A 5 24 VDC 27 4 VDC 26 VDC 28 77 VDC 45 A 6 30 VDC 28 5 VDC 31 5 VDC 45 A 7 33 VDC 31 4 VDC 34 65 VDC 45 A 8 36 VDC 34 2 VDC 37 8 VDC 45 A 9 38 VDC 36 1 VDC 39 9 VDC 45 A A 36 VDC 41 1 VDC 39 VDC 43 16 VDC see curve B 36 VDC 41...

Страница 9: ...ut cables of the charger output short circuit Connect the charger to the power line Follow the Status led color Switch ON the charger from the on off switch Count all the number of green blinks There must be as much number of blinks as the code switch position number is Note If the position of the code switch is O Status led blinks only once and returns to red The code switch positions A F respond...

Страница 10: ...e The output voltage can be tuned 5 from its nominal value Choose such programmed output voltage which can reach the desired voltage by 5 adjustment Read the instruction from Changing programmed voltage Connect the voltage meter to output wires Tune with a small screw driver the voltage calibration trimmer and check the result from volt meter Clockwise direction increases the voltage Look at the p...